Biological Safety Cabinet

LORDERAN Class II B2 Biological Safety Cabinet, 100% Total Exhaust, ULPA Filter, Touch Screen, Motorized Sash, Pro

SKU
1100IIB2-PRO-2
Availability
In stock
Questions

Ask about this instrument

LORDERAN Class II B2 Biological Safety Cabinet, 100% Total Exhaust, ULPA Filter, Touch Screen, Motorized Sash, Pro

An engineer replies by email or phone, usually within 12 hours.

Size · 3 ft
Power · 110V

A Class II B2 total-exhaust biological safety cabinet for biological work that also involves volatile toxic chemicals or radionuclides. Nothing is recirculated: room air enters at 0.53 m/s, ULPA-filtered downflow protects the work at 0.33 m/s, and all of it leaves through a dedicated duct. Widths from 3 ft to 5.2 ft, with a 7-inch touch screen and a motorized front window. Plan for the duct, its exhaust blower and the room air it removes.

LORDERAN0.33ULPA 99.9995%Class II B27" touch screen
100%air exhausted
0.53 m/sinflow velocity
0.33 m/sdownflow velocity
Φ300 mm4 m PVC exhaust duct
3 ft–5.2 ft3 widths
Pharmaceutical developmentClinical researchMicrobiology labsCell culturePharmacy compounding

Do I need a duct?

Yes. All air is exhausted through a dedicated duct to the outside. A 4 m PVC duct, Φ300 mm, is listed for every model.

A2 or B2?

B2 when biological work also involves volatile toxic chemicals or radionuclides. Nothing is recirculated into the work zone or the room.

When do the filters need changing?

Pressure sensors track filter life, and the controller warns you with an audible and visual alarm.

Which power does it need?

110 V or 220 V, offered for every model. Choose the voltage in the configurator.

Class II B2 Biosafety Cabinet documents

Full specifications, airflow and HEPA filtration, cabinet classes, ISO cleanliness, installation and warranty in one datasheet to share with your team. The user manual covers installation, operation and safety.
Download datasheet Download user manual

Total exhaust, zero recirculation

Every litre of air drawn into the cabinet is exhausted to the outside. That is why a B2 cabinet is the usual choice when biological work also involves volatile toxic chemicals or radionuclides.

ULPA supply filterRoom air in: inflow 0.53 m/sULPA-filtered downflow 0.33 m/s100% exhausted through the duct
  • Inflow and downflow are monitored in real time by an airflow sensor.
  • Alarms sound for abnormal airflow, filter change and an unsafe window height.
  • Interlocks stop the UV lamp while the window is open or the LED lamp is on.
  • Filter life is tracked by pressure sensors.
ISO Class 3work zone with ULPA
200 mmtested safe opening
420–500 mmmaximum opening
≤ 67 dB(A)noise

Work at the tested opening

The protective air curtain is set and tested with the front window at 200 mm. Open it wider only to load or clean; the controller sounds an alarm when the window is above the safe height. The UV lamp runs only with the window closed.

ULPAUV on200 mm500 mmAlarmWork at 200 mm (8 in)Inflow is tested here: 0.53 m/sRaise to 420–500 mm to load or cleanAlarm sounds above the safe heightClose it for UVUV lamp is interlocked with the windowULPAUV on200 mm500 mmAlarmWork at 200 mm (8 in)Inflow is tested here: 0.53 m/sRaise to 420–500 mm to load or cleanAlarm sounds above the safe heightClose it for UVUV lamp is interlocked with the window

Maximum opening by model: 420, 500 and 500 mm.

How much air leaves the building

A B2 cabinet exhausts everything it moves: the room air drawn in at the front and the filtered downflow. For the 1100IIB2-PRO that is about 1050 m³/h, which the building’s supply air has to replace.

interior width 940 mm200 mmfront windowtested opening 200 mm, air drawn in at 0.53 m/sInflow0.94 m × 0.20 m × 0.53 m/s ≈ 359 m³/hDownflow0.94 m × 0.60 m × 0.33 m/s ≈ 670 m³/hAll exhausted≈ 1029 m³/hListed for 1100IIB2-PRO1050 m³/hinterior width 940 mmfront windowtested opening 200 mm, air drawn in at 0.53 m/sInflow0.94 m × 0.20 m × 0.53 m/s ≈ 359 m³/hDownflow0.94 m × 0.60 m × 0.33 m/s ≈ 670 m³/hAll exhausted≈ 1029 m³/hListed for 1100IIB2-PRO1050 m³/h

Downflow area estimated from the interior width and depth. Plan the exhaust duct and the room’s supply air for the listed volume of the model you choose.

Specifications

Models 1100IIB2-PRO, 1500IIB2-PRO and 1800IIB2-PRO, each available in 110 V and 220 V versions.

Download the user manual (PDF)

Differs between models

Model 1100IIB2-PRO 1500IIB2-PRO 1800IIB2-PRO
Dimensions
External Dims(W × D × H) 1100 × 750 × 2255 mm 1500 × 770 × 2290 mm 1873 × 795 × 2280 mm
Internal Dims(W × D × H) 940 × 600 × 660 mm 1350 × 670 × 630 mm 1600 × 670 × 630 mm
Tested Opening Safety Height 200 mm (8 in) 200 mm (8 in) 200 mm (8 in)
Max Opening 420 mm (17 in) 500 mm (20 in) 500 mm (20 in)
Work Surface Height 750 mm
Gross Weight 315 kg 381Kg 460Kg
Package (Main Body) 1250 × 990 × 1770 mm 1650 × 990 × 1820 mm 2000 × 1075 × 1910 mm
Package (Exhaust Blower) 930 × 800 × 690 mm 930 × 800 × 710 mm 920 × 710 × 680 mm
Airflow and filtration
Inflow Velocity 0.53 ± 0.025 m/s
Down Flow Velocity 0.33 ± 0.025 m/s
CFM 100%, 1050 m3/h 100%, 1270 m3/h 100%, 1800 m3/h
Airflow System 0% air recirculation, 100% air exhaust
Exhaust Duct 4 meters PVC duct, Dia 300 mm
ULPA Filter Two, 99.9995% efficient at 0.12 μm. Filter life indicator. ULPA Filter ULPA Filter
Cabinet and electrical
Front Window Motorized, Anti UV
Noise ≤ 67 dB(A)
Consumption 600 W 800 W 1300 W
Socket Two, total load: 500 W
Standard Accessory LED lamp*2, UV lamp*2, base stand, remote control, foot switch, exhaust blower, exhaust duct, drain valve, waterproof sockets*2, pipe strap*2

Choose a size

All widths share the same airflow, filters and controls. Front elevations drawn to the same scale.

1100IIB2-PRO1100 mm3 ft · 940 mm inside1500IIB2-PRO1500 mm4.4 ft · 1350 mm inside1800IIB2-PRO1873 mm5.2 ft · 1600 mm inside1100IIB2-PRO1100 mm wide940 mm inside1500IIB2-PRO1500 mm wide1350 mm inside1800IIB2-PRO1873 mm wide1600 mm inside

Built for safe, comfortable daily work

The features you use every session, designed to keep the cabinet safe and simple to run.

100% total exhaust

No air is recirculated: everything drawn in leaves the cabinet through the exhaust system.

ULPA filtration

Two ULPA filters at 99.9995% for 0.12 μm particles: about 10 times the efficiency of HEPA, for an ISO Class 3 work zone.

7-inch touch screen

See inflow and downflow velocity, temperature and humidity, filter pressure, UV and filter run time, and filter life at a glance.

Motorized front window

Raise and lower the sash with one hand, and clean the upper glass easily.

Audible and visual alarms

Warnings for abnormal airflow, filter change and an unsafe front window height.

Safety interlocks

UV lamp with front window, UV lamp with LED lamp, and blower with front window.

Remote control

Run the main functions from up to 6 meters away.

Foot switch

Adjust the window height without lifting your hands from the work.

What's in the box

Delivered ready to work, with the accessories below as standard.

LED lamp*2UV lamp*2base standremote controlfoot switchexhaust blowerexhaust ductdrain valvewaterproof sockets*2pipe strap*2

Which biosafety cabinet is right for you?

Every LORDERAN Class II cabinet protects the operator, the sample and the environment. Choose by airflow type, size and controller.

Type
Class II A2
Class II B2This product
Air recirculated
70%
0%
Air exhausted
30%, through an ULPA filter
100%, through a dedicated duct
Exhaust connection
Not required (ductless)
Exhaust duct to outside
Typical work
Biological work without volatile or toxic chemicals or radionuclides
Biological work that also involves volatile toxic chemicals or radionuclides
Protects
Operator, sample and environment
Operator, sample and environment

Questions buyers ask

UV, warranty, returns, delivery and quotes.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. ULPA and HEPA filters, seals and other wear parts are excluded.

When can the UV lamp run?

Between sessions, to disinfect exposed surfaces. Interlocks stop it while the window is open or the LED lamp is on, so it runs only with the window closed and the work light off.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the cabinet inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Download documents

Catalogs and manuals as PDF files.

Choose width and voltage

The price and PDF quote update with your choices.

Configure yours