Fume Hood

LORDERAN Ducted Walk-in Fume Hood, Manual Tempered Glass Sash Ventilation Cabinet with External Blower System

SKU
FH1200W-220
Availability
In stock
Questions

Ask about this instrument

LORDERAN Ducted Walk-in Fume Hood, Manual Tempered Glass Sash Ventilation Cabinet with External Blower System

An engineer replies by email or phone, usually within 12 hours.

Type · FH1200W
Power · 220V

A floor-level walk-in fume hood for instruments and set-ups too large for a bench hood. The 1670 mm tall interior starts at floor level, so carts, racks and pilot equipment roll straight in, and operators can step inside when needed. An external blower exhausts 1150 to 1850 m³/h through a Φ300 mm duct; plan the duct route and the roof or wall position of the blower.

1670 mminterior height from the floor
1300 mmmaximum opening
0.3–0.8m/s inflow velocity
1150–1850m³/h exhaust
62 dBnoise
Large instrumentsDistillation and reactor set-upsPilot plantsDrum and container handlingUniversity labs

Do I need a duct?

Yes. The external blower and a 4.3 m PVC duct, Φ300 mm, come standard; the blower mounts outside on the duct.

How tall is the interior?

1670 mm from floor level, in widths of 980, 1280 and 1580 mm inside.

Which services are included?

Water and gas taps with remote-control valves, a PP cup sink and four waterproof sockets.

Which power does it need?

220 V or 110 V. Choose the voltage in the configurator.

FH1200W / FH1500W / FH1800W Walk-in Fume Hood datasheet (5 pages)

Full specifications, airflow and capture, exhaust planning, good practice, installation and warranty in one document to share with your team.
Download datasheet

Big enough to walk into

Each hood is 800 mm deep and 2250 mm tall outside. Choose the width that fits your equipment.

1.75 m personFH1200W1200 mm wideFH1500W1500 mm wideFH1800W1800 mm wide1.75 mFH1200W1200 mmFH1500W1500 mmFH1800W1800 mm

Front elevations and a 1.75 m person drawn to the same scale. The tinted area is the 1670 mm high interior.

A large room exhaust, built into one cabinet

The external blower pulls air in across the full opening at 0.3–0.8 m/s and up through the duct, keeping fumes inside the hood and away from the lab.

Room air drawn in at 0.3–0.8 m/sFumes swept to the rear baffleOut through the Φ300 mm ductNegative pressure keeps vapor inside

Section through the hood. The work area starts at floor level.

≥ 800 Luxillumination
≤ 4 μmvibration, XYZ
4waterproof sockets, ≤500 W total
4.3 mPVC duct, Φ300 mm
  • Manual toughened-glass front window, anti-UV.
  • Remote-control water and gas valves so services can be switched from outside the hood.
  • PP cup sink with water tap and gas tap inside the work area.
  • Interior lined with high-grade melamine board resistant to acids and alkalis.

Lower the sash, faster capture

The blower moves a set volume of air, about 1150 m³/h for the FH1200W. Push the same air through a smaller opening and it moves faster, so lowering the sash raises the face velocity and the hood captures fumes more reliably.

front panellisted range 0.3–0.8 m/sSash at 1300 mm (fully open)0.25 m/sSash at 650 mm0.50 m/sSash at 490 mm0.67 m/sfront panellisted range 0.3–0.8 m/sSash at 1300 mm (fully open)0.25 m/sSash at 650 mm0.50 m/sSash at 490 mm0.67 m/s

Face velocity calculated as exhaust volume ÷ (interior width 980 mm × sash opening), assuming all air enters at the sash. Many labs aim for about 0.5 m/s (100 fpm) at the working sash height; have it measured on site after installation.

Compare the three widths

Depth, height, opening, airflow velocity and accessories are the same for every model.

Model FH1200 W FH1500 W FH1800 W
External size 1200 × 800 × 2250 mm 1500 × 800 × 2250 mm 1800 × 800 × 2250 mm
Internal size 980 × 550 × 1670 mm 1280 × 550 × 1670 mm 1580 × 550 × 1670 mm
Exhaust airflow 1150 m3/h 1500 m3/h 1850 m3/h
Lamp 12 W*2 16 W*2 16 W*2
Power 400 W 500 W 800 W
Gross weight 300 kg 340 kg 390 kg

Services and safety included

The hood arrives with the blower, duct, sink and remote valves, so installation is a matter of connecting services.

Show all 15 features: Exhaust · Services · Build

Exhaust

  • External blower system
  • 4.3 m PVC exhaust duct, Φ300 mm
  • Inflow velocity 0.3–0.8 m/s
  • Exhaust 1150 to 1850 m³/h by model
  • Noise 62 dB

Services

  • Water tap and gas tap
  • PP cup sink
  • Remote control water valve
  • Remote control gas valve
  • Four waterproof sockets, ≤500 W total

Build

  • Cold-rolled steel exterior with powder coating
  • Melamine interior, acid and alkali resistant
  • Manual toughened-glass window, anti-UV
  • Lighting at ≥800 Lux
  • Vibration ≤4 μm in X, Y and Z

Specifications

Models FH1200W, FH1500W and FH1800W, each available in 110 V and 220 V versions.

Differs between models

Model FH1200 W FH1500 W FH1800 W
Dimensions
External Size (W × D × H) 1200 × 800 × 2250 mm 1500 × 800 × 2250 mm 1800 × 800 × 2250 mm
Internal Size (W × D × H) 980 × 550 × 1670 mm 1280 × 550 × 1670 mm 1580 × 550 × 1670 mm
Max Opening 1300 mm
Gross Weight 300 kg 340 kg 390 kg
Package Size (Main Body) 1400 × 1050 × 2450 mm 1700 × 1050 × 2450 mm 2010 × 1050 × 2450 mm
Package Size (Base Cabinet) 970 × 810 × 720 mm 1040 × 890 × 710 mm 1040 × 890 × 710 mm
Airflow
Exhaust Airflow Volume 1150 m3/h 1500 m3/h 1850 m3/h
Inflow Air Velocity 0.3 to 0.8 m/s
Noise 62 dB
Vibration XYZ direct ≤ 4 μm
Cabinet
Illumination ≥ 800 Lux
Fluorescent Lamp 12 W*2 16 W*2 16 W*2
Front Window Manual, Toughened glass
Material Exterior: 1.0 mm cold-rolled steel with bacteria powder coating. Interior: High grade melamine board with good acid and alkali resistance function
Electrical
Consumption 400 W 500 W 800 W
Sockets Total load of 4 waterproof sockets: ≤ 500 W
Power Supply AC220 V±10%, 50/60 Hz; 110 V±10%, 60 Hz
Accessories
Standard Accessory External Blower, LED lamp, Water tap, Gas tap, PP cup sink, Remote control water valve, Remote control gas valve, Waterproof sockets*4, 4.3 meters PVC exhaust duct (Φ 300 mm)

Questions buyers ask

Warranty, returns, delivery and quotes.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, filters and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the hood inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose width and voltage

The price and PDF quote update with your choices.

Configure yours