A Class II A2 compliant safety cabinet for compounding cytotoxic, antineoplastic and other hazardous drugs. A HEPA filter under the work surface catches contaminated air before it reaches the plenum and fan, supply and exhaust air pass ULPA filters at 99.9995% efficiency at 0.12 μm, and used filters come out into a sealed PVC bag. Three widths, 3, 4 and 5.6 ft.

0.53 m/sinflow velocity
0.33 m/sdownflow velocity
HEPA + 2 × ULPAthree-filter design
PVC bagsafe filter change
3 yearswarranty
Chemotherapy compoundingHospital pharmacyAntineoplastic drug handlingHazardous drug researchOncology clinics

Why a HEPA filter under the work surface?

Drug residue is caught at the source, so the plenum and fan stay clean and service is safer.

How are filters changed?

Through a PVC bag: the used filter is sealed in the bag as it comes out, so nobody touches it.

Do I need a duct?

No. It is Class II A2: part of the air is recirculated and the rest leaves through the exhaust ULPA filter.

Which power does it need?

110 V or 220 V for every width. Choose the voltage in the configurator.

Cytotoxic Drug Safety Cabinet, Class II A2 datasheet (5 pages)

Full specifications, airflow and HEPA filtration, cabinet classes, ISO cleanliness, installation and warranty in one document to share with your team.
Download datasheet

Hazardous drugs stay inside the cabinet

Room air enters at the front grille and shields the operator. ULPA-filtered air falls over the protected work area. Contaminated air is drawn through the grilles and captured by a HEPA filter directly beneath the work surface, so the rear plenum carries only filtered air. At the top, that air splits: part returns through the supply ULPA filter, and the rest leaves through the exhaust ULPA filter.

ULPA supply filterHEPARoom air in: inflow 0.53 m/sULPA-filtered downflow 0.33 m/sPolluted air caught by HEPA under the workExhaust leaves through ULPA

Side section. Inflow 0.53 ± 0.025 m/s, downflow 0.33 ± 0.025 m/s.

200 mmtested safe opening
440 mmmaximum opening
≤ 67 dBnoise
≥ 1000 Luxillumination
  • HEPA filtration under the work surface keeps the plenum and fan free of hazardous drug residue.
  • Work area surrounded by negative pressure for maximum containment.
  • PVC bag filter change keeps personnel and the environment safe and makes replacement quick.
  • Audio and visual alarm for filter replacement, window over height, abnormal airflow and high filter pressure.

Work at the tested opening

The protective air curtain is set and tested with the front window at 200 mm. Open it wider only to load or clean; the controller sounds an alarm when the window is above the safe height.

ULPA200 mm440 mmAlarmWork at 200 mm (8 in)Inflow is tested here: 0.53 m/sRaise to 440 mm to load or cleanAlarm sounds above the safe heightULPA200 mm440 mmAlarmWork at 200 mm (8 in)Inflow is tested here: 0.53 m/sRaise to 440 mm to load or cleanAlarm sounds above the safe height

Where the airflow figure comes from

Air enters through the front opening at the inflow speed, and the same volume leaves through the exhaust ULPA filter. Opening area × speed gives about 347 m³/h for the 3 ft model, the figure in the specifications.

interior width 910 mm200 mmfront windowtested opening 200 mm, air drawn in at 0.53 m/sOpening0.91 m × 0.2 m = 0.182 m²× inflow speed0.53 m/s = 0.0965 m³/s× 3600 s per hour≈ 347 m³/hListed for 3 ft model347 m³/hinterior width 910 mmfront windowtested opening 200 mm, air drawn in at 0.53 m/sOpening0.91 m × 0.2 m = 0.182 m²× inflow speed0.53 m/s = 0.0965 m³/s× 3600 s per hour≈ 347 m³/hListed for 3 ft model347 m³/h

The same calculation reproduces the listed airflow for every width.

Contamination control, step by step

Every part of the airflow and filter path is designed around one goal: hazardous particles reach a filter, never a person.

Inflow barrier

Room air enters the front grille at 0.53 ± 0.025 m/s and forms a curtain between the operator and the work.

Clean downflow

ULPA-filtered air at 0.33 ± 0.025 m/s washes the work zone and keeps preparations free of particles.

Filtered at the source

Contaminated air passes a HEPA filter beneath the work surface, then the exhaust ULPA filter, before it leaves the cabinet.

Bagged filter change

Used filters are removed into a sealed PVC bag, so nobody is exposed during maintenance.

Three widths for every pharmacy

The 3, 4 and 5.6 ft models share the same airflow, filters and controls. Choose by how many preparations run side by side.

3 ft1087 mm910 mm inside4 ft1380 mm1220 mm inside5.6 ft1877 mm1700 mm inside3 ft1087 mm wide910 mm inside4 ft1380 mm wide1220 mm inside5.6 ft1877 mm wide1700 mm inside

External width and height drawn to scale.

Model 3 ft 4 ft 5.6 ft
Exhaust volume 347 m³/h 465 m³/h 648 m³/h
UV lamp 20 W*1 30 W*1 40 W*1
LED lamp 12 W*2 16 W*2 16 W*2
Power 700 W 900 W 1300 W
Gross weight 320 kg 371 kg 430 kg

Everything included as standard

Most accessories ship with the cabinet, including a remote control that runs every function, so the cabinet is ready for work on delivery.

Control

  • Microprocessor control system
  • LCD display with humidity and temperature shown on the panel
  • Remote control for all functions
  • Motorized front window
  • Automatic air speed adjustment with filter loading

Safety

  • ULPA supply filter, 99.9995% at 0.12 μm
  • HEPA under the work surface plus exhaust ULPA
  • Negative-pressure surround work area
  • Alarms for airflow, filter, window height and filter pressure
  • Germicidal UV at 253.7 nm

Build

  • 304 stainless steel work area
  • Cold-rolled steel body with anti-bacteria powder coating
  • Motorized two-layer laminated toughened glass, anti-UV
  • Water tap, gas tap and two waterproof sockets
  • Footmaster casters on the base stand

Specifications

Models 11224BBC86, 11234BBC86 and 11244BBC86, each available in 110 V and 220 V versions.

Differs between models

Model 11224BBC86 (3 ft) 11234BBC86 (4 ft) 11244BBC86 (5.6 ft)
Dimensions
External Dims (W × D × H) 1087 × 760 × 2100 mm 1380 × 760 × 2100 mm 1877 × 760 × 2100 mm
Internal Dims (W × D × H) 910 × 600 × 630 mm 1220 × 600 × 630 mm 1700 × 600 × 630 mm
Tested Opening Safety Height 200 mm (8 in)
Max Opening 440 mm (17 in)
Gross Weight 320 kg 371 kg 430 kg
Package Size (W × D × H) 1240 × 910 × 2280 mm 1540 × 910 × 2280 mm 2050 × 910 × 2260 mm
Airflow and filtration
Inflow Velocity 0.53 ± 0.025 m/s
Down Flow Velocity 0.33 ± 0.025 m/s
Exhaust Volume 347 m³/h 465 m³/h 648 m³/h
Air Supply Filter ULPA filter, efficiency > 99.9995% for particle size at 0.12 μm
Exhaust Filter ULPA filter: first exhaust filter: 0.12 μm efficiency 99.9995%; HEPA filter: secondary exhaust filter: 0.3 μm efficiency 99.995%
Cabinet
Alarm Abnormal airflow velocity; Filter replacement; Front window at unsafe height; High filter pressure alarm
Noise ≤ 67 dB
Water & Gas Tap Water Tap*1, Gas tap*1
UV Lamp 20 W*1 30 W*1 40 W*1
Emission of 253.7 nanometers for most efficient decontamination
LED Lamp 12 W*2 16 W*2 16 W*2
Illumination ≥ 1000 Lux
Display LCD display
Control System Microprocessor
Humidity and Temperature Humidity and temperature can be displayed on the control panel
Material Work Area: 304 stainless steel. Main Body: cold-rolled steel with anti-bacteria powder coating
Front Window Motorized, two-layer laminated toughened glass ≥ 6 mm, anti-UV
Caster Footmaster Caster
Electrical
Consumption 700 W 900 W 1300 W
Waterproof Socket Two, Total load of two sockets: ≤ 500 W
Power supply AC220 V±10%, 50/60 Hz; 110 V±10%, 60 Hz
Accessories
Standard Accessory Base stand, Drain valve, Waterproof sockets*2, Remote control, LED lamp*2, UV lamp*1, Water tap, Gas tap
Optional Accessory Armrest, Formalin fumigation sterilizer, Infrared sterilizer, Airflow tester

Questions buyers ask

Warranty, returns, delivery and quotes.

Does it alarm when something is wrong?

Yes. Audio and visual alarms cover filter replacement, window over height, abnormal airflow and high filter pressure.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. ULPA and HEPA filters, seals and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the cabinet inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose width and voltage

The price and PDF quote update with your choices.

Configure yours