LORDERAN Wrist Action Lab Shaker - 0-600 RPM Variable Speed Benchtop Shaker with Adjustable 6/12/15° Angle & 12/16-Position Capacity15,235 SR
LORDERAN · Wrist Action Lab Shaker
Wrist-like motion. Precisely controlled.
Servo-driven wrist action with a 5-inch touch screen and programmable speed sequences. Choose 12 or 16 positions for controlled multi-vessel shaking.
Servo motor±1 rpm frequency accuracy12 or 16 positions
0–600rpm frequency range
±1 rpmFrequency accuracy
5-inchColor touch screen
12 / 16Maximum vessel positions
A deliberate change of direction
Set the motion. Define the method.
The arms oscillate back and forth to reproduce a wrist-like shaking action. Select the frequency and arm angle to suit your vessels, fill volume and procedure.
Servo drive and PID microprocessor control provide a specified frequency accuracy of ±1 rpm.
Motion illustration; animation speed and curve are not measured performance data.
Frequency
Set the oscillation frequency within the specified 0–600 rpm range.
Angle
10° nominal tilt, with 6°, 12° and 15° settings listed in the technical specifications.
Timing
Set time in seconds and start timing when the selected speed is reached.
Specifications
Models ZD-C810 and ZD-C820.Differs between models
Model
ZD-C810
ZD-C820
Model and dimensions
Maximum positions
12
16
Main unit dimensions
272 × 452 × 300 mm
272 × 452 × 320 mm
Arm length, each side
348 mm
468 mm
Net weight
45 kg
46.5 kg
Motion and performance
Shaking motion
Wrist action
Reciprocating frequency
0–600 rpm
Frequency accuracy
±1 rpm
Tilt angle
10° nominal; 6°, 12° and 15° settings listed
Oscillation radius
13.3 ±0.4 cm
Control and timing
Control system
PID microprocessor control
Drive
Servo motor
Display
5-inch color touch screen
Programming
30 stages; up to 100 cycles
Timer setting
Second-level setting; timing can begin at the selected speed
Watchdog timer; independent audible and visual overspeed alarm
Electrical protection
Independent leakage-current and electrical over-limit protection
Installation and configuration
Operating environment
User-specified temperature-controlled room or suitable ambient environment
Circulation description
Natural convection
Supply voltage
110V/220V
Vessel clamps / included items
12/16
Dimensions are reproduced in the order provided in the technical documents; axis orientation is not specified. Confirm the complete installed footprint, loading limits and final controller configuration before ordering.
Two capacities. One control platform.
12 or 16 positions. Choose your capacity.
The same frequency range and control accuracy, with two vessel capacities. Select by position count, arm length and available bench space.
LORDERAN · ZD-C810
Compact arm configuration
12positions
For workflows that need up to 12 vessel positions with shorter arms.
Arm length, each side
348 mm
Main unit dimensions
272 × 452 × 300 mm
Net weight
45 kg
LORDERAN · ZD-C820
More vessel positions
16positions
For workflows that need up to 16 vessel positions and can accommodate longer arms.
Arm length, each side
468 mm
Main unit dimensions
272 × 452 × 320 mm
Net weight
46.5 kg
Position count is not a load rating. Usable capacity depends on vessel geometry, fill volume, clamp fit and the approved loading arrangement. Main-unit dimensions exclude the arms and vessel clearance.
Designed around the operator
Clear settings. Practical control.
Direct access to the settings that matter: speed, time, program and operating status.
01
Settings in view
View set and actual speed and time, operating status and alarm records on the 5-inch touch screen.
02
Programmed sequences
Build sequences of up to 30 stages and repeat them for up to 100 cycles, as specified in the model parameter tables.
03
Servo-driven control
A servo motor regulates oscillation frequency. Parameter memory and speed storage support recurring procedures.
04
A stable mechanical core
A precision-machined, single-cast ductile iron chassis supports the drive assembly and twin shaking arms.
05
Practical construction
A 304 stainless steel housing and aluminum arms combine a laboratory-oriented exterior with accessible vessel mounting.
06
Clear daily operation
An English interface, a screen-lock key and a clock display keep routine settings and status accessible.
Overspeed alerts
Independent audible and visual overspeed alarms.
Electrical protection
Independent leakage-current and electrical over-limit protection devices.
Operating memory
Parameter retention and power-restoration recovery functions are listed for both models. Confirm restart behavior for your procedure.
Fit comes before vessel count
Your vessels. The right configuration.
Suitable vessel types include Erlenmeyer flasks, reagent bottles, test tubes and separatory funnels. Compatibility depends on the selected clamps and loading arrangement.
01 · Vessel geometry
Provide vessel type, capacity, neck diameter and overall dimensions so the appropriate clamp arrangement can be confirmed.
02 · Working load
Specify fill volume, total loaded mass and the number of vessels. Confirm support and clearance for the chosen angle.
03 · Method settings
Share your target frequency, angle, timing and operating environment to check the configuration against your procedure.
Before you order
Practical answers for laboratory purchasing and method planning.
How do the two models differ?
ZD-C810 provides up to 12 positions, 348 mm arms on each side and a net weight of 45 kg. ZD-C820 provides up to 16 positions, 468 mm arms and a net weight of 46.5 kg. Main-unit dimensions also differ; confirm axis orientation with the final drawing.
Does it operate like an orbital shaker?
No. This instrument uses an alternating wrist-like action rather than a circular orbital path. Confirm that this motion matches your laboratory procedure.
Are vessels and clamps included?
The listed clamp configuration is 12 / 16. Confirm the clamp arrangement for your selected model, compatible vessel sizes and whether glassware is included.
Can it control sample temperature?
No active heating, cooling or temperature-control range is specified. The documents call for a user-selected temperature-controlled room or suitable ambient environment.
Can I use it for a pharmacopoeial test?
Confirm suitability against the exact method and current edition you use. Request the applicable configuration and supporting documentation; the listed motion settings are not a certification or a guarantee of method compliance.
What should I confirm about power and loading?
The listed supply options are 110 V / 220 V. Confirm your selected configuration, supply frequency, plug, rated power, maximum permissible load and installed clearance.