Biological Safety Cabinet

LORDERAN Cytotoxic Biological Safety Cabinet with 99.9995% ULPA Filter, Motorized Sash Window Lab Biosafety Hood, Class II A2 Compliant

SKU
11224BBC86-2
Availability
In stock
Brand
LORDERAN
Power · 110V
Size · 3 Ft

A Class II A2 compliant safety cabinet built for handling cytotoxic, antineoplastic and other hazardous drugs. Supply and exhaust air pass ULPA filters at 99.9995% efficiency at 0.12 μm, and a HEPA filter under the work surface captures contaminated air before it reaches the plenum. Filters are changed through a PVC bag, so the operator never touches a contaminated filter. Backed by a 3-year warranty.

0.53 m/sinflow velocity
0.33 m/sdownflow velocity
HEPA + 2 × ULPAthree-filter design
PVC bagsafe filter change
3 yearswarranty
Chemotherapy compoundingHospital pharmacyAntineoplastic drug handlingHazardous drug researchOncology clinics

Hazardous drugs stay inside the cabinet

Room air enters at the front grille and shields the operator. ULPA-filtered air falls over the protected work area. Contaminated air is drawn through the grilles and captured by a HEPA filter directly beneath the work surface, so the rear plenum carries only filtered air. At the top, that air splits: part returns through the supply ULPA filter, and the rest leaves through the exhaust ULPA filter.

Side section. Inflow 0.53 ± 0.025 m/s, downflow 0.33 ± 0.025 m/s.

200 mmtested safe opening
440 mmmaximum opening
≤67 dBnoise
≥1000 Luxillumination
  • HEPA filtration under the work surface keeps the plenum and fan free of hazardous drug residue.
  • Work area surrounded by negative pressure for maximum containment.
  • PVC bag filter change keeps personnel and the environment safe and makes replacement quick.
  • Audio and visual alarm for filter replacement, window over height, abnormal airflow and high filter pressure.

Contamination control, step by step

Every part of the airflow and filter path is designed around one goal: hazardous particles reach a filter, never a person.

Inflow barrier

Room air enters the front grille at 0.53 ± 0.025 m/s and forms a curtain between the operator and the work.

Clean downflow

ULPA-filtered air at 0.33 ± 0.025 m/s washes the work zone and keeps preparations free of particles.

Filtered at the source

Contaminated air passes a HEPA filter beneath the work surface, then the exhaust ULPA filter, before it leaves the cabinet.

Bagged filter change

Used filters are removed into a sealed PVC bag, so nobody is exposed during maintenance.

Three widths for every pharmacy

The 3, 4 and 5.6 ft models share the same airflow, filters and controls. Choose by how many preparations run side by side.

3 ft1087 mm910 mm inside4 ft1380 mm1220 mm inside5.6 ft1877 mm1700 mm inside

External width and height drawn to scale.

Model 3 ft 4 ft 5.6 ft
Exhaust volume 347 m³/h 465 m³/h 648 m³/h
UV lamp 20W*1 30W*1 40W*1
LED lamp 12W*2 16W*2 16W*2
Consumption 700W 900W 1300W
Gross weight 320kg 371kg 430kg

Everything included as standard

Most accessories ship with the cabinet, including a remote control that runs every function, so the cabinet is ready for work on delivery.

Control

  • Microprocessor control system
  • LCD display with humidity and temperature shown on the panel
  • Remote control for all functions
  • Motorized front window
  • Automatic air speed adjustment with filter loading

Safety

  • ULPA supply filter, 99.9995% at 0.12 μm
  • HEPA under the work surface plus exhaust ULPA
  • Negative-pressure surround work area
  • Alarms for airflow, filter, window height and filter pressure
  • Germicidal UV at 253.7 nm

Build

  • 304 stainless steel work area
  • Cold-rolled steel body with anti-bacteria powder coating
  • Motorized two-layer laminated toughened glass, anti-UV
  • Water tap, gas tap and two waterproof sockets
  • Footmaster casters on the base stand

Specifications

Models 11224BBC86, 11234BBC86 and 11244BBC86, each available in 110 V and 220 V versions.

Differs between models

Model 11224BBC86 (3 ft) 11234BBC86 (4 ft) 11244BBC86 (5.6 ft)
Dimensions
External Dims (W*D*H) 1087*760*2100mm 1380*760*2100mm 1877*760*2100mm
Internal Dims (W*D*H) 910*600*630mm 1220*600*630mm 1700*600*630mm
Tested Opening Safety Height 200mm (8")
Max Opening 440mm (17")
Gross Weight 320kg 371kg 430kg
Package Size (W*D*H) 1240*910*2280mm 1540*910*2280mm 2050*910*2260mm
Airflow and filtration
Inflow Velocity 0.53±0.025m/s
Down Flow Velocity 0.33±0.025m/s
Exhaust Volume 347m³/h 465m³/h 648m³/h
Air Supply Filter ULPA filter, efficiency > 99.9995% for particle size at 0.12 μm
Exhaust Filter ULPA filter: first exhaust filter: 0.12μm efficiency 99.9995%; HEPA filter: secondary exhaust filter: 0.3μm efficiency 99.995%
Cabinet
Alarm Abnormal airflow velocity; Filter replacement; Front window at unsafe height; High filter pressure alarm
Noise ≤67dB
Water & Gas Tap Water Tap*1, Gas tap*1
UV Lamp 20W*1 30W*1 40W*1
Emission of 253.7 nanometers for most efficient decontamination
LED Lamp 12W*2 16W*2 16W*2
Illumination ≥1000Lux
Display LCD display
Control System Microprocessor
Humidity and Temperature Humidity and temperature can be displayed on the control panel
Material Work Area: 304 stainless steel. Main Body: cold-rolled steel with anti-bacteria powder coating
Front Window Motorized, two-layer laminated toughened glass ≥6mm, anti-UV
Caster Footmaster Caster
Electrical
Consumption 700W 900W 1300W
Waterproof Socket Two, Total load of two sockets: ≤500W
Power supply AC220V±10%, 50/60HZ; 110V±10%, 60Hz
Accessories
Standard Accessory Base stand, Drain valve, Waterproof sockets*2, Remote control, LED lamp*2, UV lamp*1, Water tap, Gas tap
Optional Accessory Armrest, Formalin fumigation sterilizer, Infrared sterilizer, Airflow tester

Free shipping

Free shipping on all orders, with some international restrictions.

Warranty

Major defects under warranty are covered by a full refund or replacement.

30-day money back

Return most new, unopened items within 30 days.

DDP shipping

Delivered duty paid, so there are no surprise import charges on arrival.