Flame AAS Spectrophotometer AA-1800D, 8-lamps

Flame AAS Spectrophotometer AA-1800D, 8-lamps

AA-1800 atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. 

  • High precision automatic optical system

    1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 6 socket configuration six independent lamp power supply, can be respectively preheating.

     

    Polymer spray chamber

    Polymer materials corrosion spray chamber, acid and alkali resistance, including hydrofluoric acid, either organic or inorganic solution can be the highest sensitivity and stability.

     

    Titanium burner

    Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency and accuracy of the flame.

     

    Automatic analysis

    It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.

    The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automatic wavelength scanning and searching peak.

     

    Software function

    High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method.

  • Model AA-1800D
    Light Source ≤8 lamps automatic turret, automatic alignment
    Power Supply 110/220V (+5% ~ -10%), 60/50Hz; 5000VA
    Lamp Current pulsed power supply
    Optical System large 1800 /mm grating ruling, full closed optical system
    Wavelength Range 180nm-900nm, Automatically peak find,a key optical optimization function                                             
    Wavelength Accuracy ≤0.15nm
    Wavelength Repeatability ±0.1nm
    Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (5 steps with automatic changeover)
    Baseline Stability ≤±0.002A/30 min (Static) 
    ≤±0.005A/30min (Dynamic)
    Absorbance Range 0-4A
    Flame Analytical System  
    Detector imported photo multiplier tube
    Burner Head full titanium combustion head, 50mm or 100mm general combustion head
    Atomization Chamber polymer explosion-proof spray chamber
    Nebulizer atomizer efficient glass atomizer, can also be customized
    Ignition Type microcomputer control, automatic ignition
    Gas Control automatic gas control system
    Detection Limits(Cu) 0.002μg/mL
    Precision RSD≤0.5%

Lorderan provides Incubator, Biosafety Cabinet and Tablet Tester. the trusted manufacturer in lab equipment.