CO2 Incubator

LORDERAN 90℃ Moist Heat Sterilization CO2 Incubator, Professional Cell Culture Incubator with Infrared IR Sensor

SKU
C80II
Availability
In stock
Questions

Ask about this instrument

LORDERAN 90℃ Moist Heat Sterilization CO2 Incubator, Professional Cell Culture Incubator with Infrared IR Sensor

An engineer replies by email or phone, usually within 12 hours.

Volume · 80L (2.82 Cu. Ft.)
Power · 110V

LORDERAN · C-II SERIES

Precision CO₂ incubation.

Air-jacketed CO₂ incubator with infrared sensing, PT100 temperature control and a dedicated 90 °C moist heat decontamination cycle. Available in 80 L and 160 L.

90 °C moist heatInfrared CO₂ sensorAir jacket + PID
Cell cultureTissue engineeringPharmaceutical researchBiotechnology
LORDERAN TEMPERATURE 37.0 °C CO₂ 5.0 % 90 °C Moist heat cycle 0–20 vol% Infrared CO₂ control
90 °CMoist heat cycle
0–20 vol%CO₂ control range
±0.3 °CFluctuation at 37 °C
80 / 160 LTwo chamber capacities
TECHNICAL DATASHEET · PDF · 6 PAGES

C80II / C160II 90 °C Moist Heat CO₂ Incubator datasheet

Full specifications, CO₂ and medium pH reference values, the 90 °C decontamination cycle, installation and warranty in one document to share with your team.
Download datasheet

CULTURE CONTROL

Temperature and
CO₂ control.

PID temperature control uses a PT100 sensor. CO₂ is regulated by a dual-channel, dual-filter infrared sensor supplied with a calibration certificate.

Temperature · relative response CO₂ · relative response TargetTarget ConditioningTime →
01 · Setpoints02 · Response03 · Regulation
Illustrative control responses on relative scales; not measured data.
RT + 5 to 60 °CIncubation temperature range
0.1 vol%CO₂ control resolution
0.2 vol%CO₂ uniformity

RT = room temperature. The lower incubation limit is 5 °C above ambient: 30 °C at a room temperature of 25 °C.

CHAMBER DECONTAMINATION

90 °C moist heat
decontamination.

A dedicated moist heat cycle supports chamber decontamination between culture runs. The 90 °C cycle is separate from routine incubation.

Refer to the model-specific instructions for cycle preparation and compatible accessories.

90 °C60 °C37 °C 90 °C moist heat cycle Incubation reference CultureDecontaminationReturn to culture
Illustrative sequence at a 37 °C incubation reference; no cycle duration is specified.
±0.3 °CTemperature fluctuationAt 37 °C
±0.5 °CTemperature uniformityAt 37 °C
0.1 °CTemperature precision
0–999 hTimer rangeOr continuous operation

Chamber design
and operation.

Humidity monitoring, accessible controls and a cleanable stainless steel interior support routine culture work.

Air-jacket design

Air-jacket construction supports the chamber’s controlled thermal environment.

7-inch touch screen

Touch-screen operation with a 0–999 h timer or continuous running.

Humidity monitoring

Real-time display of chamber humidity during operation.

Water reservoir

Bottom-mounted reservoir with a low-water-level alarm.

304 stainless steel

Electrochemically treated interior with rounded internal corners.

Adjustable shelves

Two adjustable shelves for vessel and tray placement.

Temperature & CO₂ alarms

Over-temperature, under-temperature, high-CO₂ and low-CO₂ alarms.

Water-level monitoring

Low-water-level alarm for the chamber reservoir.

Electrical protection

Leakage-current and over-voltage protection.

80 L or 160 L.

Compare internal dimensions, cabinet footprint and power consumption. Both models share the same control specifications.

80 L

C80II

650 WPower consumption

Internal W × D × H368 × 452 × 517 mm

External W × D × H611 × 773 × 841 mm

Net weight72 kg

160 L

C160II

700 WPower consumption

Internal W × D × H468 × 552 × 648 mm

External W × D × H711 × 873 × 991 mm

Net weight95 kg

Cabinet profiles are drawn to a common scale.

01 · SAMPLE SPACE

Vessel clearance.

Check internal dimensions and shelf positions against your vessels or trays.

02 · ENVIRONMENT

Ambient conditions.

Ambient range: 5–30 °C. Recommended: 25 ±2 °C.

03 · UTILITIES

Power and gas.

Select 110 V or 220 V. Confirm the CO₂ supply and installation requirements.

04 · DECONTAMINATION

Cycle requirements.

Review the moist heat procedure and accessory compatibility for your workflow.

Specifications

C80II and C160II. Select 110 V or 220 V.

Differs between models

Model C80II C160II
Model and dimensions
SKU C80II C160II
Capacity 80 L (2.82 cu ft) 160 L (5.65 cu ft)
Internal size W × D × H (mm) 368 × 452 × 517 mm 468 × 552 × 648 mm
External size W × D × H (mm) 611 × 773 × 841 mm 711 × 873 × 991 mm
Packing size W × D × H (mm) 725 × 887 × 985 mm 820 × 1010 × 1128 mm
Net weight 72 kg 95 kg
Gross weight 93 kg 120 kg
Temperature and decontamination
Type Air jacket
Sterilization type 90 °C moist heat sterilization
Temperature sensor PT100
Temperature range RT+5 to 60 °C
Temperature fluctuation ±0.3 °C (at 37 °C)
Temperature uniformity ±0.5 °C (at 37 °C)
Temperature precision 0.1 °C
CO₂ control
CO₂ sensor IR infrared sensor with calibration certificate
CO₂ range 0–20 vol%
CO₂ uniformity 0.2 vol%
CO₂ control resolution 0.1 vol%
Filter CO₂ gas filter
Sensor technology Dual-channel, dual-filter infrared technology
Controls, chamber and humidity
Display 7-inch touch screen
Timing range 0–999 h or continuous
Shelves 2 pcs, adjustable
Humidity display Real-time humidity display
Water reservoir Bottom-mounted water reservoir
Interior 304 stainless steel, electrochemically treated; semicircular inner corners
Temperature control PID control
Electrical and operating environment
Power consumption 650 W 700 W
Voltage 110 V or 220 V
Ambient temperature 5–30 °C (recommended 25±2 °C)
Accessories and protection
Standard accessories Shelves, USB interface, CO₂ relief valve, CO₂ gas filter
Optional accessories Water pump, three-way connector
Temperature alarms Over-temperature and under-temperature alarms
CO₂ alarms Over-concentration and under-concentration alarms
Water-level alarm Low-water-level alarm
Electrical protection Leakage-current and over-voltage protection

Dimensions: width × depth × height. CO₂ values: volume percent (vol%). Amber markers indicate model-dependent values.

Operating conditions. RT = room temperature. Incubation: RT + 5 °C to 60 °C. Decontamination: 90 °C. Temperature fluctuation and uniformity are specified at 37 °C. Humidity is monitored; an active RH control range is not specified.

Configuration and
accessories.

Select the capacity and voltage above. Optional accessories are specified separately.

Standard equipment

  • Two adjustable shelves
  • USB interface
  • CO₂ relief valve
  • CO₂ gas filter

Optional accessories

  • Water pump
  • Three-way connector

Specify optional items when ordering.

Application and installation support.

Confirm culture conditions, CO₂ supply and cycle compatibility. Request model-specific operating documents before installation.

Contact LORDERAN

Technical questions.

Operating limits and configuration at a glance.

What does RT + 5 °C mean?

RT is room temperature. The lower incubation limit is 5 °C above ambient: 30 °C at a room temperature of 25 °C. The upper limit is 60 °C.

Is 90 °C used during incubation?

90 °C is used for the separate moist heat decontamination cycle. Routine incubation operates at RT + 5 °C to 60 °C.

What do the CO₂ specifications mean?

CO₂ range: 0–20 vol%. Control resolution: 0.1 vol%. Uniformity: 0.2 vol%. The infrared sensor is supplied with a calibration certificate.

Is humidity actively controlled?

Humidity is displayed in real time. A bottom water reservoir and low-water-level alarm are included; an active RH control range is not specified.

What should I confirm before ordering?

Confirm 80 L or 160 L, 110 V or 220 V, installation dimensions and CO₂ supply. Specify the optional water pump or three-way connector if required.

Free shipping

Free shipping on all orders, with some international restrictions.

2-year warranty

2-year warranty. Major defects under warranty are covered by a full refund or replacement.

30-day money back

Return most new, unopened items within 30 days.

DDP shipping

Delivered duty paid, so there are no surprise import charges on arrival.