Constant Temperature and Humidity Test Chamber

LORDERAN Constant Temperature and Humidity Test Chamber with Water Recirculation, 0-100°C, 20%-98% RH Precision Humidity Control Chamber for Electronics, Material Test and Microbial Culture

SKU
HWS150
Availability
In stock
Brand
Lorderan
Capacity · 150L
Power · 110V

A constant temperature and humidity chamber for the long, steady tests that cannot be interrupted: stability studies, shelf-life testing, material conditioning and bioproduct storage. It holds 0 to 100 °C and 20 to 98 %RH with ±0.5 °C fluctuation, while a variable-frequency compressor, thick insulation and a water recirculation system keep running costs and refills low. Four sizes from 150 to 1000 L, with a 2-year warranty.

Temperature + humidityWater recirculationVariable-frequency compressorR290 refrigerant2-year warranty
LORDERAN20–98 %RH0 °C ⇄ 100 °C
0–100 °Ctemperature range
20–98 %RHhumidity range
±0.5 °Ctemperature fluctuation
±2 %RHhumidity fluctuation
150–1000 Lfour sizes
Stability testingShelf-life testingMaterial testingBioproduct storageElectronics
2-year warrantyMajor defects: full refund or replacement.
Free shipping, DDPDuties paid, no surprise import charges.
30-day money backReturn most new, unopened items.
110 V or 208–240 VChoose the supply that matches your lab.
DATASHEET + USER MANUAL · PDFConstant Temperature and Humidity Test Chamber documentsThe datasheet puts all four sizes and specifications on one sheet for your team. The user manual covers installation, operation, water care and safety.Download datasheet Download user manual

The stable damp-heat working zone

Temperature runs from 0 to 100 °C. Where temperature and humidity are controlled together, the chamber holds the coloured zone steadily for weeks. The three markers are the ICH stability conditions many labs run every day; all three sit comfortably inside.

01020304050607080901000102030405060708090100Temperature (°C)Relative humidity (%RH)Temperature only: 0 to 100 °CCONTROLLED T + H ZONEhumidity controlled, 15 to 85 °C15 °C · 90 %60 °C · 90 %85 °C · 20 %60 °C · 20 %Long-term 25/60Intermediate 30/65Accelerated 40/75
Controlled temperature and humidity zoneICH long-termICH intermediateICH accelerated
90 %RHacross the top of the zone from 15 to 60 °C, easing slightly toward 85 °C.
20 %RHis reachable from 60 to 85 °C; at lower temperatures the minimum humidity rises, as the zone boundary shows.
Outside the zone?Conditions beyond the guaranteed range need a feasibility check. Ask our engineers before you order.

Specifications

Models HWS150, HWS250, HWS500 and HWS1000, in 110 V and 208–240 V versions.

Differs between models

Model 150L 250L 500L 1000L
Model and size
SKU HWS150 HWS250 HWS500 HWS1000
Inner size (W*D*H) 600*405*620mm 600*500*830mm 800*700*900mm 1000*1000*1000mm
External size (W*D*H) 830*800*1500mm 830*900*1700mm 1030*960*1790mm 1230*1400*1850mm
Test Hole 100mm*1
Racks 2
Weight 170kg 190kg 320kg 400kg
Temperature and humidity
Temperature range 0~100℃
Humidity range 20~98% RH
Temperature fluctuation ±0.5℃
Humidity fluctuation ±2%RH
Temperature deviation ±1.5℃
Humidity deviation ±3.0%RH
Refrigeration, control and power
Refrigeration method High-efficiency direct cooling
Compressor Hermetic compressor
Cooling method Air cooled
Refrigerant R290
Temperature sensor Platinum resistance PT100
Display Touch Screen
Power 1.5kw 1.5kw 2.5kw 2.5kw

Choose a size

Same range, controller and protection on every size. Front elevations drawn to the same scale.

150L · HWS150830 mm600*405*620 inside250L · HWS250830 mm600*500*830 inside500L · HWS5001030 mm800*700*900 inside1000L · HWS10001230 mm1000*1000*1000 inside

Ready for long-term stability studies

Typical ICH conditions for drug substances and products, all inside the controlled zone, held for months at low running cost.

Long-term25 °C / 60 %RH

Real-time stability at standard storage conditions.

Intermediate30 °C / 65 %RH

When accelerated results show a significant change.

Accelerated40 °C / 75 %RH

Faster degradation for early shelf-life estimates.

Conditions as commonly specified in ICH Q1A(R2). Your protocol defines the exact conditions and durations.

Water recirculation: weeks without refilling

Condensate and unevaporated water are collected and pumped back to the humidifier reservoir, for more than 80% better water utilization, less DI or RO water, no external drain line and unattended running for weeks or months.

ReservoirDI / RO waterHumidifiersteam to chamberTest chamberhigh-humidity testCondensatecollectedReturn pumpfiltered waterReturn linewater reusedOver 80% higher water utilization

Engineered to run cheaply for months

Energy-saving design and the details that make long tests simple.

Variable-frequency compressor

Output follows the load instead of cycling at full speed, for steadier control and lower energy use.

Thicker insulation

Low-conductivity insulation reduces the work the heater and compressor must do.

Automatic water refill

A recirculation tank feeds the humidifier automatically.

Optimized air duct

Even airflow for better temperature and humidity uniformity.

SUS 304B interior

Acid- and corrosion-resistant stainless steel that wipes clean.

R290 refrigerant

A natural refrigerant, in an air-cooled hermetic system.

Touch screen, PT100

Clear touch control with a platinum resistance PT100 sensor.

100 mm test hole

Run cables to powered samples during the test.

Low power, standard sockets

Current draw is low enough for ordinary lab circuits.

6.8 A150 L and 250 L at 220 V
13 A150 L and 250 L at 110 V
11.4 A500 L and 1000 L at 220 V
22 A500 L and 1000 L at 110 V

Safety protection

The chamber protects itself, your samples and your lab.

Show all 4 safety protections
  • Compressor overload protection
  • Humidification heater dry-burn protection: power is cut when reservoir water is too low
  • Over-temperature protection: heating, and if needed cooling, shut down
  • Electrical short-circuit protection

Find the right LORDERAN environmental chamber

Steady climate, damp heat or fast ramps: choose by how your product must be tested.

Chamber
Constant T&H 0–100 °CThis product
Temperature
0 to 100 °C
−40 to 150 °C
−70 to 150 °C
60 to 100 °C
−70 to 150 °C
Humidity
20–98 %RH
20–98 %RH
20–98 %RH
80–98 %RH
20–98 %RH
Best for
Stability, shelf-life, storage
General climate testing
Climate testing down to −70 °C
Double 85 / Double 95
Stress screening, 5–15 °C/min
Sizes
150–1000 L
100–1000 L
100–1000 L
150–1000 L
100–1000 L

Questions buyers ask

Straight answers before you order.

Can it run ICH stability conditions?

Yes. 25 °C / 60 %RH, 30 °C / 65 %RH and 40 °C / 75 %RH all sit inside the controlled temperature and humidity zone.

Which humidity is possible at which temperature?

See the control range chart: humidity is controlled from 15 to 85 °C, up to about 90 %RH; the minimum humidity rises at lower temperatures. Outside the zone, ask our engineers.

How often do I need to add water?

Rarely. The water recirculation system reuses condensate and unevaporated water and refills the humidifier automatically, for weeks or months of unattended running.

Which voltage should I order?

Every size is offered in 110 V and 208–240 V versions. The 150 L and 250 L draw 6.8 A at 220 V; the 500 L and 1000 L draw 11.4 A at 220 V.

What does the warranty cover?

A 2-year warranty. Major non-repairable defects under warranty are covered by a full refund or replacement.

Free shipping

Free shipping on all orders, with some international restrictions.

2-year warranty

2-year warranty. Major defects under warranty are covered by a full refund or replacement.

30-day money back

Return most new, unopened items within 30 days.

DDP shipping

Delivered duty paid, so there are no surprise import charges on arrival.