Fume Hood

LORDERAN Ducted Fume Hood P Series, Strong Acid and Alkali Resistant Laboratory Fume Hood with Blower, Phenolic Resin Bench, Manual Front Window

SKU
FH1000P-110
Availability
In stock
Questions

Ask about this instrument

LORDERAN Ducted Fume Hood P Series, Strong Acid and Alkali Resistant Laboratory Fume Hood with Blower, Phenolic Resin Bench, Manual Front Window

An engineer replies by email or phone, usually within 12 hours.

Type · FH1000P
Power · 110V

A fume hood for strong acids and alkalis. The body is porcelain-white PP, the worktop is phenolic resin and the 5 mm toughened glass window resists acid and alkali too. A PP centrifugal blower with 9 speeds sends fumes out through a Φ250 mm duct. Four widths; it needs a duct to the outside.

LORDERAN0.5 m/sStrong acidsPP bodyΦ250 duct
Strongacid and alkali resistance
0.3–0.8m/s air velocity
560–1130m³/h exhaust
740 mmmaximum opening
1047–1847mm, four widths
Chemistry labsSample digestionSolvent handlingTeaching labsQC labs

Do I need a duct?

Yes. Fumes leave the building through a PVC duct, Φ250 mm. If you cannot run one, look at the ductless hood.

Why PP instead of steel?

PP does not corrode in strong acid and alkali vapor, where a coated steel body would be attacked over time.

How hard is installation?

Assemble the base cabinet, fix the main body on top, then connect the exhaust duct and power.

Which power does it need?

110 V or 220 V for every model. Choose the voltage in the configurator.

Fume Hood P Series CatalogAll four widths, specifications and accessories in one document to share with your team.Download catalog

Fumes go up and out, never toward you

The blower draws room air in across the whole opening and up behind the rear baffle. Fumes are carried into the duct and outside the building, and the work area stays at negative pressure, so vapour cannot spill back into the room.

Room air drawn in at 0.3–0.8 m/sFumes swept to the rear baffleOut through the Φ250 mm ductNegative pressure keeps vapor inside
  • Negative pressure keeps vapour inside the hood.
  • Blower speed adjusts in 9 levels to suit the work.
  • Lower the sash to raise the face velocity at the opening.
  • The phenolic resin worktop resists the chemicals it handles.
560–1130 m³/hexhaust volume
Φ250 mmPVC exhaust duct
9 levelsblower speed
740 mmmaximum opening

Lower the sash, faster capture

The blower moves a set volume of air, about 700 m³/h for the FH1200P. Push the same air through a smaller opening and it moves faster, so lowering the sash raises the face velocity and the hood captures fumes more reliably.

front panellisted range 0.3–0.8 m/sSash at 740 mm (fully open)0.27 m/sSash at 390 mm0.51 m/sSash at 300 mm0.66 m/sfront panellisted range 0.3–0.8 m/sSash at 740 mm (fully open)0.27 m/sSash at 390 mm0.51 m/sSash at 300 mm0.66 m/s

Face velocity calculated as exhaust volume ÷ (interior width 987 mm × sash opening), assuming all air enters at the sash. Many labs aim for about 0.5 m/s (100 fpm) at the working sash height; have it measured on site after installation.

Specifications

Models FH1000P, FH1200P, FH1500P and FH1800P, each available in 110 V and 220 V versions.

Download the full catalog (PDF)

Differs between models

Model FH1000P FH1200P FH1500P FH1800P
Dimensions
External Size (mm) (w*d*h) 1047 × 800 × 2450 1247 × 800 × 2450 1547 × 800 × 2450 1847 × 800 × 2450
Internal Size (mm) (w*d*h) 787 × 560 × 700 987 × 560 × 700 1287 × 560 × 700 1587 × 560 × 700
Work Surface Height 820 mm
Max Opening 740 mm
Gross Weight 226 kg 254 kg 294 kg 346 kg
Main Packing Size 1188 × 938 × 1612 1388 × 938 × 1612 1688 × 938 × 1612 1988 × 938 × 1612
Base Packing Size 1188 × 888 × 1000 1388 × 888 × 1000 1688 × 888 × 1000 1988 × 888 × 1000
Airflow
Air Velocity 0.3 to 0.8 m/s
Exhaust Volume 560 m³/h 700 m³/h 920 m³/h 1130 m³/h
Exhaust Duct PVC, Φ250 mm
Blower 1 1 1 2
Cabinet and electrical
LED Lamp 24 W*1 24 W*1 30 W*1 38 W*1
Front Window Manual
Consumption 400 W 400 W 500 W 700 W
Optional Accessory Active carbon filter

Choose a size

Every width shares the same controls, materials and air velocity. Front elevations drawn to the same scale.

FH1000P1047 mm787 mm insideFH1200P1247 mm987 mm insideFH1500P1547 mm1287 mm insideFH1800P1847 mm1587 mm insideFH1000P1047 mm wide787 mm insideFH1200P1247 mm wide987 mm insideFH1500P1547 mm wide1287 mm insideFH1800P1847 mm wide1587 mm inside

Why labs choose it

Built to handle chemicals safely, day after day.

Strong acid resistance

PP body, phenolic resin worktop and acid-resistant glass for aggressive chemistry.

Manual front window

5 mm toughened glass, height adjustable.

9-level air speed

A PP centrifugal blower; the 1800 model has two.

Microprocessor panel

Alarms for unsafe conditions, low noise and vibration.

PP water tap and sink

With a PP gas tap, supplied as standard.

Power-off memory

Settings are kept through a power cut.

Optional carbon filter

Add an active carbon filter when required.

Easy to install

Assemble the base and fix the main body.

What's in the box

Standard accessories, so installation is just a matter of connecting services.

2 waterproof socketsPP water tapPP gas tapWater sinkPP centrifugal blowerPipe straps ×2 (×4 for FH1800P)

Compare the LORDERAN fume hood range

Five series, one standard of safety. Pick the body, window and exhaust that suit your chemistry.

Series
P SeriesThis product
Body
Cold-rolled steel
Cold-rolled steel
PP, porcelain white
Cold-rolled steel
Cold-rolled steel
Front window
Motorized
Manual
Manual
Motorized
Manual, acrylic
Exhaust
Duct, Φ300 mm
Duct, Φ300 mm
Duct, Φ250 mm
Duct, Φ300 mm
No duct, chemical filter
Resistance
Weak acids, alkalis
Weak acids, alkalis
Strong acids, alkalis
Weak acids, alkalis
Weak acids, alkalis
Filter
Carbon, optional
Optional
Carbon, optional
Carbon included
Chemical, included
Widths
1040–1840 mm
1000–1800 mm
1047–1847 mm
1000–1800 mm
1000–1800 mm

Questions buyers ask

Options, warranty, returns, delivery and quotes.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, filters and other wear parts are excluded.

Can I add a filter?

Yes. An active carbon filter is available as an option.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the hood inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Download documents

Catalog, user manual and service manual as PDF files.

Choose width and voltage

The price and PDF quote update with your choices.

Configure yours