Laminar Flow Cabinet

LORDERAN Horizontal Laminar Flow Cabinet with HEPA Filter, ISO Class 5 Clean Bench for Laboratory & PCR Cell Culture

SKU
H1100-110
Availability
In stock
Questions

Ask about this instrument

LORDERAN Horizontal Laminar Flow Cabinet with HEPA Filter, ISO Class 5 Clean Bench for Laboratory & PCR Cell Culture

An engineer replies by email or phone, usually within 12 hours.

Model · H1100
Power · 110V

A horizontal laminar flow clean bench for sterile, non-hazardous work: HEPA-filtered air crosses the work surface from the back of the cabinet toward you, so particles from the operator and the room are carried away from the sample, giving an ISO Class 5 work zone. Four widths, open-front or with a motorized window, supplied with a base stand. It does not protect the operator.

ISO 5Class 100 work zone
99.999%HEPA at 0.3 μm
0.3–0.5m/s horizontal airflow
3.6–6 ftfour widths
3 yearsworldwide warranty
Electronics assemblyPlant tissue cultureMedia preparationPCR set-upSterile, non-hazardous work

Does it protect the operator?

No. It protects the sample by blowing clean air toward you. For infectious or hazardous materials, choose a Class II biosafety cabinet.

Open front or window?

H1100 and H1500 are open-front. H1300 and H1800 add a motorized front window opening to 430 mm.

When does the filter need changing?

The HEPA filter is rated for 5,000 hours; the controller raises a replacement alarm at 3,500 hours.

Which power does it need?

110 V or 220 V for every model. Choose the voltage in the configurator.

Clean air that flows toward you

A fan draws room air through the washable pre-filter and pushes it through a HEPA filter covering the back wall. The filtered air crosses the work surface in parallel, unidirectional streams and leaves through the open front, so the sample always sits upstream of your hands, your breath and the room.

HEPAHEPA filter: 99.999% at 0.3 μmClean air toward you at 0.3–0.5 m/sSample stays upstream of hands and room

Side section. The cabinet is held under constant positive pressure, so room air cannot drift in.

99.999%HEPA at ≥0.3 μm
<65 dBnoise
253.7 nmUV decontamination
750 mmwork surface height
  • Glass-fibre HEPA filter, damp-proof and fire-proof.
  • Washable polyester-fibre pre-filter protects the HEPA filter.
  • Laminar flow cabinets protect the sample only. For infectious or hazardous materials, choose a biosafety cabinet.
  • Transparent side glass brightens the work zone.

What ISO Class 5 means

ISO 14644-1 sets the most particles of 0.5 μm and larger that a cubic meter of air may hold: 3,520 for ISO Class 5. Per liter, the volume of a large bottle, that is about three or four particles; each class above allows ten times more.

ISO 5 · this bench≤ 3.5 per literISO 6≤ 35 per literISO 7≤ 352 per literISO 5≤ 3.5 per literISO 6≤ 35 per literISO 7≤ 352 per liter

Limits from ISO 14644-1 for particles ≥ 0.5 μm, shown per liter (1/1000 m³). Ordinary indoor air is typically ISO 8 to 9, up to 3,520 to 35,200 particles per liter. Class 100 is the older US FED-STD-209E name for ISO 5.

What a clean bench protects

A laminar flow cabinet blows clean air over the work and out toward you, so it keeps the sample clean but sends anything the sample releases into your face and the room. For infectious material, choose a Class II biosafety cabinet; for chemical fumes, a fume hood.

Laminar flowthis cabinetClass II BSCbiosafety cabinetFume hoodductedSampleOperatorExhaust filteredLaminarflowClass IIBSCFumehoodSampleOperatorExhaust filtered

Specifications

Models H1100, H1500, H1300 and H1800, each available in 110 V and 220 V versions. "/" means not applicable to the open-front models.

Differs between models

Model H1100 H1500 H1300 H1800
Dimensions
External Size (mm) (w*d*h) 1100x808x1690 1500x808x1690 1300x825x2040 1800x820x2070
Internal Size (mm) (w*d*h) 1000x500x600 1400x500x600 1200x500x570 1700x500x570
Work Surface Height 750 mm
Max Opening / / 430 mm 430 mm
Gross Weight 175 kg 216 kg 228 kg 306 kg
Packing Size (mm) 1250x1050x1350 1650x1050x1350 1450x1060x1650 1950x1030x1540
Performance
Air Velocity 0.3 to 0.45 m/s 0.3 to 0.45 m/s 0.3 to 0.5 m/s 0.3 to 0.5 m/s
Noise <65 dB
Cabinet
LED Lamp 12 W*1 16 W*1 12 W*1 16 W*1
UV Light Yes
Front Window / / Motorized Motorized
Consumption 200 W 300 W 400 W 450 W

Horizontal or vertical: how to choose

Horizontal hoods push air across the work surface and give the strongest protection to the work itself. Vertical hoods push air down, which suits large equipment that would block a horizontal stream.

Horizontal flow (this cabinet)Air sweeps across the work surfaceVertical flowAir falls onto the work surfaceHorizontal flowacross the work surfacethis cabinetVertical flowdown onto the work surface
Feature
H1100
H1500
H1300
H1800
Front window
–
–
✓
✓
Motorized window
–
–
✓
✓
ISO Level 5
✓
✓
✓
✓
HEPA filter
✓
✓
✓
✓
UV light
✓
✓
✓
✓
LED light
✓
✓
✓
✓
Base stand
✓
✓
✓
✓

Two families, four widths

Open-front H1100 and H1500 for easy access and fast work. H1300 and H1800 add a motorized front window and a taller cabinet. Front elevations drawn to scale.

H11001100 mm1000 mm insideH15001500 mm1400 mm insideH11001100 mm wide1000 mm insideH15001500 mm wide1400 mm inside

H1100 · H1500

Open front for unobstructed reach. 1000 and 1400 mm internal width, 0.3–0.45 m/s airflow.

3.6 ft5 ftOpen front
H13001300 mm1200 mm insideH18001800 mm1700 mm insideH13001300 mm wide1200 mm insideH18001800 mm wide1700 mm inside

H1300 · H1800

Motorized front window opening to 430 mm. 1200 and 1700 mm internal width, 0.3–0.5 m/s airflow.

4.3 ft6 ftMotorized window

A filter you can plan around

The HEPA filter is rated for 5,000 hours. The controller counts system work time and raises a replacement alarm at 3,500 hours, so the filter can be changed on schedule, well before performance drops.

0 hours5,000 hours

Glass-fibre HEPA filter, 99.999% or better for particles of 0.3 μm and larger.

Details that make daily work easier

A clear display, safe UV handling and practical touches for a bench that is used every day.

AIRFLOW VELOCITY0.42m/sUV TIMER30 minUV WORK TIME0126 hSYSTEM TIME1842 hREAL TIME09:41FANLIGHTUVTIMERAirflow velocity0.42 m/sUV timer30 minUV work time0126 hSystem time1842 hReal time09:41

Controls and safety

The LCD shows airflow velocity, UV timer, UV work time, system work time and real time. A UV start-up delay protects the operator, and the lamps are interlocked: switching on the fluorescent lamp turns the UV lamp off.

  • UV253.7 nm, the most efficient decontamination wavelength
  • LEDrecessed lighting to reduce eye fatigue
  • Socketstwo waterproof sockets on the side panels
  • Installassemble the base, then fix the main body

Everything at a glance

Every model shares the same filtration, lighting and controls.

Show all 15 features: Clean air · Controls · Build

Clean air

  • HEPA filter, 99.999% at ≥0.3 μm
  • Damp-proof, fire-proof glass-fibre media
  • Washable polyester-fibre pre-filter
  • ISO Class 5 work zone
  • Constant positive pressure

Controls

  • LCD with airflow velocity and timers
  • UV timer and UV work-time record
  • System work-time record and real-time clock
  • UV start-up delay
  • Fluorescent and UV lamp interlock

Build

  • Transparent side glass windows
  • Recessed LED lighting
  • Two waterproof side sockets
  • Base stand included
  • 3-year worldwide warranty

Download brochures

The full catalog and the user manuals for each model family, as PDF files.

Questions buyers ask

Warranty, returns, delivery and quotes.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. HEPA filters, seals and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the cabinet inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose model and voltage

The price and PDF quote update with your choices.

Configure yours