LORDERAN Horizontal Steam Sterilizer Autoclave, Gravity Displacement, Door Interlock, for Lab, Dental, Veterinary & Mushroom

An engineer replies by email or phone, usually within 12 hours.

Volume · 150L

A horizontal steam sterilizer from 150 to 400 L for high-volume labs, clinics and mushroom growers. It uses gravity displacement: steam enters the chamber and pushes the heavier cold air out through the drain. Sterilize at any set point from 115 to 134 °C, then dry dressings and instruments in the same chamber. It needs a three-phase supply; interlocks keep the door shut while the chamber is under pressure.

150–400 Lfour chamber sizes
115–134 °Csterilization range
0.22 MParated working pressure
0–999 minsterilize and dry timers
≤ ±2.0 °Ctemperature uniformity
100 °C142 °C

Set the sterilization temperature anywhere from 115 to 134 °C. The vessel is designed for 142 °C and 0.28 MPa.

LaboratoriesDental practicesVeterinary clinicsMushroom cultivationMedia and glassware

How is air removed?

By gravity displacement: steam enters from the top and pushes the heavier cold air out through the drain.

Which power does it need?

Three-phase 220 V or 380 V, 50/60 Hz; 12 to 18 kW by size.

Can it dry the load?

Yes. Drying runs in the same chamber after sterilizing, with a timer from 0 to 999 min.

When does the door open?

Only below 0.027 MPa. The cycle is blocked unless the door is closed and locked.

150J–400J Horizontal Steam Sterilizer datasheet (6 pages)

Full specifications, the sterilization cycle, saturated steam and F0 reference values, installation and warranty in one document to share with your team.
Download datasheet

One cycle, four stages

Steam heats the load and drives cold air out of the chamber, the temperature holds at the set point for the sterilization time, pressure is released, and the drying stage removes moisture from dressings and instruments.

115–134 °C hold12341Heat and purgegravity displacement pushes cold air out2Sterilize115–134 °C hold, 0.22 MPa3Exhaustdoor unlocks below 0.027 MPa4Dry0–999 min

Temperature through a typical 134 °C cycle. Times are set by the user.

0.28 MPadesign pressure
142 °Cdesign temperature
0.027 MPadoor unlock threshold
12–18 kWheating power
  • Door stays locked until chamber pressure drops below 0.027 MPa.
  • A cycle cannot start unless the door is securely closed.
  • Water shortage protection cuts power and sounds an alarm.
  • Automatic over-temperature and over-pressure protection.

Why it runs under pressure

Water boils at 100 °C at normal air pressure. To reach 121 °C or 134 °C, steam has to be held above atmospheric pressure, which is why the chamber is a pressure vessel. Air has to be removed first: an air and steam mixture at the same pressure is cooler than pure steam. At 134 °C the steam needs about 0.20 MPa, below the 0.22 MPa this unit is rated for.

0.00.10.20.3100110120130140temperature, °Cpressure, MPa gaugerated working pressure 0.22 MPa115 °C · lowest set point0.07 MPa (10 psi)121 °C · standard cycle0.10 MPa (15 psi)134 °C · maximum0.20 MPa (29 psi)pressure above atmospheric0.00.10.20.3100110120130140temperature, °Cpressure, MPa gaugerated working pressure 0.22 MPa115 °C · lowest set point0.07 MPa (10 psi) above atmospheric121 °C · standard cycle0.10 MPa (15 psi) above atmospheric134 °C · maximum0.20 MPa (29 psi) above atmospheric

Saturated steam pressure calculated with the IAPWS-IF97 equations, shown above atmospheric pressure (gauge). Pure steam with all air removed.

Choose by chamber size

All four models share the same pressure rating, temperature range and controls. Chamber diameter grows from 472 to 620 mm.

Model 150J 200J 300J 400J
Volume 150 L 200 L 300 L 400 L
Cavity (mm) φ472x850 φ472x1130 φ620x960 φ620x1280
Basket (mm) 780x452x217 1060x452x217 860x600x285 850x678x330
Overall (mm) 1320x635x1520 1600x635x1520 1540x790x1700 1570x875x1780
Power 12 kW 15 kW 18 kW 18 kW

How gravity displacement works

No vacuum pump is needed. Steam does the work, because it is lighter than air.

Fill

Water from the supply at 0.1–0.2 MPa is heated to make steam inside the vessel.

Purge

Steam fills the chamber from the top and pushes cold air down and out of the drain.

Sterilize

The load holds at 115–134 °C for the time you set, up to 999 minutes.

Exhaust and dry

Pressure is released, then the drying stage runs for up to 999 minutes.

Safety built into every step

A manual structure that operators know, with modern interlocks and protection.

Safety

  • Door locked until pressure is below 0.027 MPa
  • Cycle blocked unless the door is closed
  • Water shortage protection with alarm
  • Over-temperature protection
  • Over-pressure protection

Process

  • Gravity displacement air removal
  • Sterilization temperature 115–134 °C
  • Sterilization time 0–999 min
  • Drying time 0–999 min
  • Temperature uniformity ≤±2.0 °C

Build

  • High-quality stainless steel chamber
  • Strong corrosion resistance
  • Horizontal loading with baskets
  • Three-phase power supply
  • Drying for dressings and instruments

Specifications

Models 150J, 200J, 300J and 400J. "/" means not applicable to this gravity displacement design.

Differs between models

Model 150J 200J 300J 400J
Main technical parameters
Design pressure 0.28MPa
Design temperature 142°C
Working pressure 0.22MPa
Operating temperature 115-134°C
Temperature uniformity ≤ ±2.0°C
Water source pressure 0.1 to 0.2MPa
Vacuum /
Compressed air pressure /
External steam pressure /
Power supply voltage (220 V or 380 V), Three-phase 50/60 Hz
Product parameters
Volume 150 L 200 L 300 L 400 L
Power 12 kW 15 kW 18 kW 18 kW
Voltage AC 380 V/220 V 50/60 Hz (3-phases)
Rated working pressure 0.22MPa
Rated working temperature 134°C
Sterilization temperature selection range 115 to 134°C
Sterilization time selection range 0 to 999 min
Drying time selection range 0 to 999 min
Dimensions and weight
Cavity dimensions (mm) φ472x850 φ472x1130 φ620x960 φ620x1280
Basket dimensions (mm) 780x452x217 1060x452x217 860x600x285 850x678x330
Overall dimensions (mm) 1320x635x1520 1600x635x1520 1540x790x1700 1570x875x1780
Packaging dimensions (L×W×H) (mm) 1470x785x1720 1750x785x1720 1690x940x1900 1830x1025x1980
Gross/net weight 350/270 kg 410/310 kg 600/450 kg 680/510 kg

Questions buyers ask

Warranty, returns, delivery and quotes.

What does the warranty cover?

A 1-year warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the autoclave inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose your size

The price and PDF quote update with your choices.

Configure yours