Lab Shaker

LORDERAN Floor Incubator Shaker 0-300 rpm, Temperature Controlled Shaking Incubator for Cell Culture, 24/7 Ultra-Low Noise

SKU
211B-110
Availability
In stock
Questions

Ask about this instrument

LORDERAN Floor Incubator Shaker 0-300 rpm, Temperature Controlled Shaking Incubator for Cell Culture, 24/7 Ultra-Low Noise

An engineer replies by email or phone, usually within 12 hours.

Model · 211B
Power · 110V

A floor-standing incubator shaker built for continuous, around-the-clock culture work. The 211 series holds 186 L or 245 L anywhere from 4 °C to 60 °C to ±0.1 °C, while a single-shaft balanced drive turns an 890 × 480 mm platform from 30 to 300 rpm. Intelligent defrosting keeps it running for long stretches at low temperature.

186 / 245 L211B / 211C chamber
4–60 °C±0.1 °C accuracy
±0.2 °Cuniformity
0–300rpm, ±1 rpm
890 × 480mm shaking plate
4 °C60 °C

Heating at 800 W and refrigeration at 200 W with CFC-free 134A coolant, under PID microcomputer control.

211B or 211C?

Same 1250 mm width and 890 × 480 mm plate; the 211C adds 110 mm of chamber height, enough for 5000 ml flasks.

What temperatures?

4 to 60 °C, ±0.1 °C accuracy and ±0.2 °C uniformity, with intelligent defrosting for long runs at low temperature.

Can it run for days?

Yes. The timer runs to 999 h 59 min or continuous, and the run restarts automatically after a power cut.

Which power does it need?

110 V or 220 V. Choose the voltage in the configurator.

TECHNICAL DATASHEET · PDF · 5 PAGES

211B / 211C Floor Incubator Shaker datasheet

Full specifications, capacity planning, motion and temperature performance, installation requirements and warranty in one document to share with your team.
Download datasheet

Built to run around the clock

Long fermentations and multi-day cultures need a shaker that never drifts and never stops by accident. The 211 series stores its settings, restarts itself after a power cut and defrosts automatically, so a run can go on for days.

Timer from 0 to 999 h 59 min, or continuous

999 h 59timer, or continuous
±1 rpmrotary accuracy
Ø 25 mmorbital shaking
120 Winverter motor
  • Intelligent defrosting for long continuous operation at low temperature.
  • Rotary speed and parameters are stored, and the run restarts automatically when power returns.
  • Single-shaft balanced drive with a maintenance-free brushless motor and soft start.
  • Watchdog timer, clock display and parameter encryption keep a running protocol safe.

Speed and orbit set the mixing

How hard the platform pushes your flasks depends on speed and orbit: the peak acceleration grows with the square of the speed and in proportion to the orbit. At 300 rpm a 25 mm orbit reaches about 1.26 g.

25 mm orbit0 g0.5 g1 g1.5 g0100200300speed, rpm1.26 g25 mm orbit0 g0.5 g1 g1.5 g0100200300speed, rpm1.26 g25 mm orbitup to 300 rpm: 1.26 g peak

Peak acceleration = (2π × rpm / 60)² × orbit radius, in multiples of g (9.81 m/s²). The drawing shows the orbits to scale.

Two heights, one footprint

Both models stand 1250 mm wide and share the same 890 × 480 mm shaking plate. The 211C adds 110 mm of chamber height, enough to take 5000 ml flasks.

1250 mm 1060 mm 211B 186 L chamber 375 mm high 1250 mm 1210 mm 211C 245 L chamber 485 mm high
Model 211B 211C
Volume 186L 245L
Chamber size 970×550×375 mm 970×550×485 mm
External size 1250×650×1060 mm 1250×740×1210 mm
Largest flask 2000 ml 5000 ml
Net weight 253kg 265kg

All other specifications are shared by both models.

Plan your plate

The 890 × 480 mm shaking plate takes flasks from 250 ml to 5000 ml. Each layout shows the maximum load for one flask size.

5000 ml× 6 maximum 211C only

2000 ml× 12 maximum

1000 ml× 18 maximum

500 ml× 28 maximum standard

250 ml× 43 maximum

Standard configuration

Supplied with both models.

28× 500 ml flask positions

Layouts are illustrative and show the maximum number of flasks of one size. 5000 ml flasks fit the 211C only.

Even air, steady temperature

Forced air convection moves heated or cooled air through the whole chamber, so flasks at the edge of the plate see the same conditions as those in the centre.

Temperature range

Cool incubation through warm culture

4–60 °C

Control accuracy

±0.1 °C

PID microcomputer control, with set and actual values on a dual LCD.

800 Wheater
200 Wcooler

Uniformity

±0.2 °C

Forced convection keeps the whole plate within a tight band.

134ACFC-free coolant
1120 Wpower

Protection at every step

Independent alarms watch temperature and speed, and electrical protection guards the unit and your lab. If anything goes out of range, you hear and see it.

Control

  • PID microcomputer scanning controller
  • Large LCD shows preset and actual working parameters
  • Programs with repetition, steps and eight curves
  • Timer from 0 to 999 h 59 min, or continuous running
  • Temperature and speed calibration, clock display, room and actual temperature display

Protection

  • Sound and light alarm when temperature or speed passes its upper or lower limit
  • Independent over-temperature protector
  • Shaking stops automatically when the door opens
  • Independent electric leakage and surge protection
  • Run resumes automatically when power is restored

Everyday use

  • Ergonomic design with tempered glass window
  • Illuminating light or UV light inside the chamber
  • Intelligent defrosting for long low-temperature runs
  • Soft start prevents samples from splashing
  • Maintenance-free brushless motor for long service life

Specifications

Models 211B and 211C, each available in 110 V and 220 V versions. Values that differ between the two models are marked.

Differs between models

Model 211B 211C
Control and drive
Control Mode PID (Microcomputer scans the micro-processing chip)
Display Mode LCD (Double display of liquid crystal screen)
Circulation Mode Forced convection
Shaking Mode Orbital
Drive Mode Balancing device with single shaft
Programming Function Programming of repetition, steps and eight curves settings
Timing Range 0 -999h59mins/continuous
Motor 120W Inverter motor
Temperature
Temperature Range 4°C-60°C
Accuracy of Temperature ±0.1°C
Temperature Uniformity ±0.2°C
Coolant CFC-Free (134A)
Cooler 200W
Heater 800W
Shaking
Speed Range 30~300rpm
Rotary Accuracy ±1rpm
Orbit Dia. 25mm
Size of Shaking Plate 890×480 mm
Standard Configuration 500ml×28
Maximum Capacity 2000ml×12 or 1000ml×18 or 500ml×28 or 250ml×43 5000ml×6 or 2000ml×12 or 1000ml×18 or 500ml×28 or 250ml×43
Safety
Safety Function Speed storage, automatic shutdown, temperature and speed correction, monitoring timer, clock display, call recovery, parameter memory, parameter encryption, one-key factory reset
Additional Function Watchdog timer, independent excess speed sound/light alarm, independent electric leakage, leakage/surge protection device
Dimensions, weight and power
Volume 186L 245L
Chamber Size 970×550×375 mm 970×550×485 mm
External Size 1250×650×1060 mm 1250×740×1210 mm
Net Weight 253kg 265kg
Power 1120W
Power Supply AC 220V±10%, 50/60 Hz; 110V±10%, 60Hz

Questions buyers ask

Warranty, returns, delivery and quotes.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, belts and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the shaker inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your model and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose model and voltage

The price and PDF quote update with your choices.

Configure yours