Biological Safety Cabinet

LORDERAN Benchtop Class II A2 Biological Safety Cabinet, 99.9995% ULPA Filtration, Compact 2ft Biosafety Hood with Laminar Airflow & UV Lamp for Cleanroom, Hospital & Research

SKU
700lIA2-Z-2
Availability
In stock
Brand
Lorderan
Power · 110V

A Class II A2 biological safety cabinet that protects three things at once: you, your sample and the lab. Room air is drawn in at the front at 0.53 m/s, ULPA-filtered air falls over the work at 0.33 m/s, and 30% leaves through a second ULPA filter. A compact benchtop cabinet, a motorized front window and a 3-year warranty.

Class II A2ULPA filtrationMotorized window3-year warranty
LORDERAN0.53 m/sULPA 99.9995%Class II A20.53 m/s
0.53 m/sinflow velocity
0.33 m/sdownflow velocity
99.9995%ULPA at 0.12 μm
70 / 30% recirculated / exhausted
2 ftbenchtop width
Pharmaceutical developmentClinical researchMicrobiology labsCell culturePharmacy compounding
3-year warrantyMajor defects: full refund or replacement.
Free shipping, DDPDuties paid, no surprise import charges.
30-day money backReturn most new, unopened items.
110 V or 220 VChoose the supply that matches your lab.
CATALOG · PDFBenchtop Biological Safety Cabinet CatalogEvery model, specification and option in one document to share with your team or purchasing office.Download catalog

Three protections in one airflow

Inflow at the front shields you. ULPA-filtered downflow keeps the sample clean. The 30% that leaves passes an exhaust ULPA filter, so the lab stays clean too, with no duct required.

  • Inflow and downflow are monitored in real time by an airflow sensor.
  • Alarms sound for abnormal airflow, filter change and an unsafe window height.
  • Interlocks stop the UV lamp while the window is open or the LED lamp is on.
  • Filter life is tracked by pressure sensors.
ISO Class 3work zone with ULPA
200 mmtested safe opening
380 mmmaximum opening
≤65 dB(A)noise

Specifications

Model 700lIA2-Z, available in 110 V and 220 V versions.

Download the PDF
Model 700lIA2-Z
Dimensions
External Dims (W*D*H) 700*650*1280 mm
Internal Dims (W*D*H) 600*500*540 mm
Tested Opening Safety height: 200mm(8")
Max Opening 380 mm
Net Weight 130kg
Gross Weight 145kg
Package Size (W*D*H) 760*787*1500 mm
Airflow and filtration
CFM 230m³/h
Inflow Velocity 0.53±0.025 m/s
Down Flow Velocity 0.33±0.025 m/s
Airflow System 70% air recirculation, 30% air exhaust
ULPA Filter Two, 99.9995% efficient at 0.12μm. Filter life indicator.
Cabinet and electrical
Front Window Motorized. Two-layer laminated toughened glass 5mm. Anti UV.
Noise ≤65dB(A)
Consumption 700W
Socket Two, total load of two sockets: 500W
Standard Accessory LED lamp*2, UV lamp*1, Remote control, Drain Valve*1, Waterproof Sockets*2, Foot Switch

Built for safe, comfortable daily work

The features you use every session, designed to keep the cabinet safe and simple to run.

Benchtop footprint

A full Class II A2 cabinet that sits on an ordinary lab bench and saves floor space.

ULPA filtration

Two ULPA filters at 99.9995% for 0.12 μm particles: about 10 times the efficiency of HEPA, for an ISO Class 3 work zone.

Real-time display

Filter life, fan run time and UV lamp run time, with an alarm below 10% remaining filter life.

Motorized front window

Raise and lower the sash with one hand, and clean the upper glass easily.

Time reserve

Schedule start-up and sterilizing so you skip about 30 minutes of waiting before and after work.

Audible and visual alarms

Warnings for abnormal airflow, filter change and an unsafe front window height.

Safety interlocks

UV lamp with front window, UV lamp with LED lamp, and blower with front window.

Remote control

Run the main functions from up to 6 meters away.

What's in the box

Delivered ready to work, with the accessories below as standard.

LED lamp*2UV lamp*1Remote controlDrain Valve*1Waterproof Sockets*2Foot Switch

Which biosafety cabinet is right for you?

Every LORDERAN Class II cabinet protects the operator, the sample and the environment. Choose by airflow type, size and controller.

Type
Class II A2This product
Class II B2
Air recirculated
70%
0%
Air exhausted
30%, through an ULPA filter
100%, through a dedicated duct
Exhaust connection
Not required (ductless)
Exhaust duct to outside
Typical work
Biological work without volatile or toxic chemicals or radionuclides
Biological work that also involves volatile toxic chemicals or radionuclides
Protects
Operator, sample and environment
Operator, sample and environment

Questions buyers ask

Straight answers before you order.

Do I need to connect a duct?

No. A Class II A2 cabinet recirculates 70% of the air and discharges 30% through an ULPA exhaust filter, so it can run without a duct.

When should I choose a B2 cabinet instead?

If your biological work also involves volatile toxic chemicals or radionuclides, choose a Class II B2 total-exhaust cabinet, which recirculates no air.

Which voltage should I order?

Every model is offered in 110 V and 220 V versions. Choose the one that matches the sockets in your lab.

How do I know when the filter needs changing?

The controller tracks filter life and warns you with an audible and visual alarm when the filter needs to be changed.

What does the warranty cover?

The cabinet has a 3-year warranty. Major defects under warranty are covered by a full refund or replacement, and new, unopened items can be returned within 30 days.

Download documents

Catalogs and manuals as PDF files.

Free shipping

Free shipping on all orders, with some international restrictions.

3-year warranty

3-year warranty. Major defects under warranty are covered by a full refund or replacement.

30-day money back

Return most new, unopened items within 30 days.

DDP shipping

Delivered duty paid, so there are no surprise import charges on arrival.