LORDERAN Rapid Temperature Change Chamber -70°C to 150°C, 5/10/15°C/min Thermal Cycling Test Chamber for Semiconductor & Auto
- SKU
- KB6010
- Availability
- In stock
- Questions
Environmental stress screening and temperature cycling: −70 to 150 °C at an average 5, 10 or 15 °C/min, with 20 to 98 %RH, in four sizes from 100 to 1000 L. Fast swings expose weak solder joints, cracked packages and marginal components before products ship; which rates you can order, and whether they need a water chiller, depends on the size.
How fast is 15 °C/min?
About 15 min for the full −70 to +150 °C sweep; 10 °C/min takes about 22 min, 5 °C/min about 44 min. Average rates, no load.
Air or water cooling?
Most versions let you choose. Water only: 250 and 500 L at 15 °C/min, 1000 L at 10 or 15 °C/min, with a 12 to 25 HP chiller.
Do I need a water line?
No. The humidifier runs from a built-in tank of RO or DI water, and condensate drains back into it by gravity.
Which power does it need?
Three-phase: 208, 220–240, 400, 415 or 480 V, 50/60 Hz. Rated power 8 to 65.5 kW, by size, rate and cooling type.
Choose how fast the temperature moves
The ramp rate sets how hard each cycle stresses the product. At 15 °C per minute the chamber crosses the full 220 °C span in about a quarter of an hour, so more cycles fit into every test day and failures surface sooner.
Rates are non-linear averages measured with no load. A heavy or high-mass sample slows the ramp.
- Mechanical binary (cascade) refrigeration reaches −70 °C.
- Ceramic heating elements with PID control for tight, even heating.
- Broadband forced air circulation, out at the top and in at the bottom.
- Set different variable rates for different stress-screening profiles.
What a faster rate buys you
Screening profiles alternate hot and cold dwells, and every ramp between them is test time. In the same two hours, the 15 °C/min version completes 3 full −40 ↔ +85 °C cycles and the 5 °C/min version completes 1, so a campaign of a few hundred cycles finishes in a fraction of the days.
Example set-point profile: −40 ↔ +85 °C with 10 min dwells, drawn from the published average rates, no load; a heavy sample slows every ramp. Not measured chamber data.
How it moves the temperature that fast
Strong heating and a two-stage refrigeration system drive the change; forced air carries it to every shelf.
Simplified section, not to scale. Blue arrows show the air path: out at the top, back at the bottom. Screen values are an example.
-
1Load the samples.Space them out on the shelves and keep the load light: mass slows every ramp. Cables go through the 100 mm test hole.
-
2Set the profile.On the 7-inch touch screen, set temperature, humidity and time for each step, with its own rate. 100 programs × 100 steps.
-
3Ramp.Ceramic heaters and the cascade refrigeration change the air temperature; the fan sends the air out at the top and draws it back at the bottom.
-
4Measure and correct.PID control compares actual with set values and trims heating, cooling and humidity together.
-
5Record.The test curve is logged with no time limit. Alarms and live data reach your PC or phone.
Specifications
Four chamber sizes, each available at 5, 10 or 15 °C/min.
Download the full datasheet (PDF)Differs between models
| Model | 100 L | 250 L | 500 L | 1000 L |
|---|---|---|---|---|
| Model and size | ||||
| SKU | KB6010 | KB6025 | KB6050 | KB6100 |
| Interior Size (W × D × H) | 450 × 450 × 500 mm | 600 × 600 × 700 mm | 800 × 700 × 900 mm | 1000 × 1000 × 1000 mm |
| Shelves | 2 | 2 | 3 | 3 |
| Exterior and packing size (W × D × H) | ||||
| Exterior · 5 °C/min water-cooled | 780 × 1300 × 1580 mm | 960 × 1500 × 1760 mm | 1130 × 1550 × 1950 mm | 1320 × 1890 × 2050 mm |
| Exterior · 5 °C/min air-cooled, 10/15 °C/min | 780 × 1600 × 1700 mm | 960 × 2420 × 1760 mm | 1130 × 2500 × 1980 mm | 1320 × 2800 × 2080 mm |
| Packing · 5 °C/min water-cooled | 850 × 1450 × 1900 mm | 1100 × 1610 × 1980 mm | 1250 × 1650 × 2160 mm | 1450 × 2050 × 2250 mm |
| Packing · 5 °C/min air-cooled, 10/15 °C/min | 930 × 1860 × 1840 mm | 1100 × 2550 × 1910 mm | 1300 × 2700 × 2200 mm | 1450 × 2960 × 2300 mm |
| Packing note | Outer dimensions of the export crate, pallet included | |||
| Performance | ||||
| Temperature range | −70 to 150 °C | |||
| Humidity range | 20 to 98 %RH | |||
| Temperature fluctuation | ±0.5 °C | |||
| Humidity fluctuation | ±2–3 %RH | |||
| Temperature deviation | ±1.0 °C | |||
| Humidity deviation | ±2.0 %RH (>75%); ±3.0 %RH (≤ 75%) | |||
| Heating-up time | Non-linear average 5/10/15 °C/min, no load. | |||
| Cooling down time | Non-linear average 5/10/15 °C/min, no load. | |||
| Control method | Balanced temperature and humidity control (BTHC) with PID intelligent adjustment | |||
| Power and cooling | ||||
| Power, 5 °C/min | 8 kW (air-cooled) | 10 kW (air-cooled) | 13 kW (air-cooled) | 28.5 kW (water-cooled) |
| Power, 10 °C/min | 11 kW (air-cooled) | 23 kW (air-cooled) | 29 kW (water-cooled) | 47 kW (water-cooled) |
| Power, 15 °C/min | 13.5 kW (air-cooled) | 25 kW (water-cooled) | 44 kW (water-cooled) | 65.5 kW (water-cooled) |
| Cooling, 5 °C/min | Air, or water with a 5 HP chiller | Air, or water with a 5 HP chiller | Air, or water with a 8 HP chiller | Air, or water with a 12 HP chiller |
| Cooling, 10 °C/min | Air, or water with a 8 HP chiller | Air, or water with a 12 HP chiller | Air, or water with a 12 HP chiller | Water only, 20 HP chiller |
| Cooling, 15 °C/min | Air, or water with a 8 HP chiller | Water only, 12 HP chiller | Water only, 15 HP chiller | Water only, 25 HP chiller |
| Refrigeration system | Mechanical binary (cascade) refrigeration | |||
| Power supply | 3-phase: 208, 220–240, 400, 415 or 480 V; 50/60 Hz | |||
| Construction | ||||
| Display | 7-inch touch screen | |||
| Inner Body Material | SUS304 mirror stainless steel plate | |||
| Insulation Material | Special ultra-fine glass wool + polyurethane foam for rapid temperature change test chamber | |||
| Airflow Mode | Broadband forced air circulation (top out and bottom in) | |||
| Humidifier Device | Special stainless-steel humidifier | |||
Will it fit your lab?
Check doorways and floor space before you order. Front views are drawn to scale beside a standard 36 × 80 in door.
Drawn at the largest configuration. The 5 °C/min water-cooled models are shallower: D 1300 / 1500 / 1550 / 1890 mm. Measure the clear opening of your door, which is smaller than the door leaf. Crate sizes are in the specification table.
Size, speed and cooling at a glance
Faster ramps and larger chambers need more refrigeration. Each cell shows the power rating and the cooling you can order for that size and rate. Water cooling runs on an external chiller of the size shown.
Air cooled or water cooled
The choice follows the ramp rate you need and the services in your building. Air cooling uses built-in fans and finned-tube condensers; water cooling moves heat from the refrigerant into an external water loop and suits larger chambers and faster rates.
Temperature, humidity and time on one controller
Set temperature, humidity and time together for every step. The chamber holds humidity without producing condensation inside, and the cascade refrigeration, SUS304 inner chamber and controller are built to run for weeks without a break.
Humidity management
20 to 98 %RH with no condensation produced in the chamber.
Temperature control
Anywhere from −70 °C to 150 °C, held within ±0.5 °C.
One controller
Set temperature, humidity and time from the 7-inch touch screen.
Temperature cycling
Average ramps of 5, 10 or 15 °C/min, set step by step.
Cooling system
Two-stage cascade compression cooling pulls the workspace down to −70 °C.
Integrated chamber
SUS304 mirror stainless inner chamber, insulated with ultra-fine glass wool and polyurethane foam.
Continuous testing
Runs for weeks without a break, with the test curve logged the whole time.
What stress screening catches
Fast temperature change finds the weak parts of a product long before a customer does.
One chamber, many names
A rapid temperature change (humidity) chamber is named after the screening method it runs. The same chamber covers all of them.
- ESSEnvironmental Stress Screening
- ASTAccelerated Stress Testing
- Burn-intest
Simulate harsh environments
Run fast temperature change (ESS) and condensation tests, with either the temperature test or the average temperature test method.
Accelerate product reliability
Weak parts fail early. Fast temperature swings bring those early failures forward into the lab, so the products that ship sit in the long, flat part of the curve. Solder fatigue life falls steeply as the temperature swing grows (the Coffin–Manson relation), which is why screening profiles use wide, fast swings. The chamber meets the stress-screening requirements for electronic equipment in these documents.
Water recirculation: a closed loop
Condensate from the chamber drains back to the humidifier tank by gravity, so most of the water is used again. That keeps long, unattended high-humidity tests running and cuts DI / RO water use.
- No water line
- the humidifier runs from a built-in tank
- Water
- RO or DI only
- Reuse
- condensate drains back into the tank by gravity
- Long tests
- less refilling during unattended high-humidity runs
Fill the tank with RO or DI water only; never use tap water.
Inside the heating, cooling and electrics
Heaters, refrigeration and electrics chosen for fast, repeatable cycling, in a cabinet insulated with ultra-fine glass wool and polyurethane foam.
Ceramic heating
Ceramic heating elements transfer heat quickly. PID control holds the fluctuation to ±0.5 °C and the deviation across the workspace to ±1.0 °C.
Refrigeration
Two compressor stages in a mechanical binary (cascade) system: the high stage cools the low stage, which reaches −70 °C and carries ramps of up to 15 °C/min.
Electrical
Circuits laid out to USA standards with coded wiring and diagrams. Components from Schneider, Carlo Gavazzi, Mitsubishi and Rainbow; Danfoss and SAGINOMIYA solenoid valves.
Thirteen layers of protection
Separate protections cover the sample, the refrigeration system and the operator. On a fault the chamber shuts down and the circulation fan runs on for the delay you set. Remote control from a PC or phone, with remote assistance, lets you check a running test away from the lab.
- Test sample over-temperature protection
- Circulation motor overload protection
- Compressor overload protection
- Compressor over-pressure protection
- Heater / humidifier dry-burn protection
- Water shortage protection
- Input power missing-phase and reverse-phase protection
- Independent protection switches in the secondary circuit for lamp and anti-condensation wiring
- Electric leakage protection
- Three-color light alarm
- Test sample terminal and equipment chain-control protection
- Fault shutdown with circulation fan delay stop, settable 0–50 min (default 5 min)
- Flame-retardant non-metallic materials: wire, cable, terminals, insulation
Programming and data
A 7-inch touch screen with time-segment and real-time programming, and a test curve record with no time limit.
Show all 15 features: Programming · Monitoring · Construction
Programming
- Time-segment and real-time programming
- 100 × 100 customizable programs
- Separate variable rates per screening profile
- Temperature, humidity and time set together
- Temperature test and average temperature test methods
Monitoring
- Complete real-time test curve analysis, no time limit
- Troubleshooting system with alarms
- Remote control via PC and phone
- Remote assistance feature
- Three-color light alarm
Construction
- SUS304 mirror stainless steel inner body
- Ultra-fine glass wool + polyurethane foam insulation
- Special stainless-steel humidifier
- Top-out, bottom-in forced air circulation
- 2 shelves (100 / 250 L) or 3 shelves (500 / 1000 L)
Reference standards
Test methods and chamber specifications this chamber is designed to.
Show all 17 standards: IEC 60068, GB/T 2423, GJB 150
- IEC60068-2-1.1990Test Methods for Low Temperature Test Chambers
- IEC60068-2-2.1974Test Methods for High Temperature Test Chambers
- IEC60068-2-1:2007 (GB/T2423.1-2008)Environmental testing – Part 2: Test methods – Tests A: Cold
- IEC60068-2-2:2007 (GB/T2423.2-2008)Environmental testing for electric and electronic products Test methods – Tests B: Dry Heat
- IEC 60068-2-14 2009Environmental testing – Part 2-14: Tests – Test N: Change of temperature
- GB/T2423.22-2002Test Methods for Temperature Variations
- GB/T2423.4-2008Test Methods for Cyclic Damp Heat Tests
- GB/T2423.3-2006Test Methods for Thermal-humidity Test Chambers
- GB/T10586-89Specifications for Thermal-humidity Test Chambers
- GB/T2423.1-2008Test Methods for Low Temperature Test Chambers
- GB/T2423.2-2008Test Methods for High Temperature Test Chambers
- GB10592-89Specifications for Low/High Temperature Test Chambers
- GB10589-89Specifications for Low Temperature Test Chambers
- GB11158Specifications for High Temperature Test Chambers
- GJB150.3High Temperature Tests
- GJB150.4Low Temperature Tests
- GJB150.9Damp Heat Tests
Questions buyers ask
Door access, options, warranty, returns, delivery and quotes.
Will it fit through my door?
Check the drawing above: each size is shown beside a standard 36 × 80 in door. The 5 °C/min water-cooled versions are the shallowest; crate sizes are in the specification table.
What does the warranty cover?
A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded. A 2-year extended warranty can be added in the configurator.
Can I add shelves or a larger test hole?
Yes. Additional shelves and a custom test hole can be added in the configurator. If a custom hole could affect the door or wall sealing, we contact you before production.
Can I return it?
Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.
How is it delivered, and when does it ship?
Freight, duties and taxes are paid to your loading dock; moving the chamber inside is not included. Your confirmed ship date is included in the order acknowledgement.
Can I get a formal quote for a purchase order?
Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.
Choose size, rate, cooling and voltage
The price, delivery date and PDF quote update with your choices.