LORDERAN 90℃ Moist Heat Sterilization CO2 Incubator, Professional Cell Culture Incubator with Infrared IR Sensor
- SKU
- C80II
- Availability
- In stock
- Questions
LORDERAN · C-II SERIES
Precision CO₂ incubation.
Air-jacketed CO₂ incubator with infrared sensing, PT100 temperature control and a dedicated 90 °C moist heat decontamination cycle. Available in 80 L and 160 L.
What is the 90 °C cycle for?
Moist heat decontamination of the chamber. Routine incubation runs from RT + 5 °C to 60 °C.
How is CO₂ measured?
By an infrared sensor: 0–20 vol%, 0.1 vol% resolution, supplied with a calibration certificate.
Is humidity controlled?
It is displayed in real time, with a bottom water reservoir and low-water alarm; an active RH control range is not specified.
What do I need on site?
A CO₂ supply and 110 V or 220 V. Choose 80 L or 160 L in the configurator.
C80II / C160II 90 °C Moist Heat CO₂ Incubator datasheet
Full specifications, CO₂ and medium pH reference values, the 90 °C decontamination cycle, installation and warranty in one document to share with your team.Download datasheetCULTURE CONTROL
Temperature and
CO₂ control.
PID temperature control uses a PT100 sensor. CO₂ is regulated by a dual-channel, dual-filter infrared sensor supplied with a calibration certificate.
RT = room temperature. The lower incubation limit is 5 °C above ambient: 30 °C at a room temperature of 25 °C.
CHAMBER DECONTAMINATION
90 °C moist heat
decontamination.
A dedicated moist heat cycle supports chamber decontamination between culture runs. The 90 °C cycle is separate from routine incubation.
Refer to the model-specific instructions for cycle preparation and compatible accessories.
Chamber design
and operation.
Humidity monitoring, accessible controls and a cleanable stainless steel interior support routine culture work.
Air-jacket design
Air-jacket construction supports the chamber’s controlled thermal environment.
7-inch touch screen
Touch-screen operation with a 0–999 h timer or continuous running.
Humidity monitoring
Real-time display of chamber humidity during operation.
Water reservoir
Bottom-mounted reservoir with a low-water-level alarm.
304 stainless steel
Electrochemically treated interior with rounded internal corners.
Adjustable shelves
Two adjustable shelves for vessel and tray placement.
Temperature & CO₂ alarms
Over-temperature, under-temperature, high-CO₂ and low-CO₂ alarms.
Water-level monitoring
Low-water-level alarm for the chamber reservoir.
Electrical protection
Leakage-current and over-voltage protection.
80 L or 160 L.
Compare internal dimensions, cabinet footprint and power consumption. Both models share the same control specifications.
80 L
C80II
650 WPower consumption
Internal W × D × H368 × 452 × 517 mm
External W × D × H611 × 773 × 841 mm
Net weight72 kg
160 L
C160II
700 WPower consumption
Internal W × D × H468 × 552 × 648 mm
External W × D × H711 × 873 × 991 mm
Net weight95 kg
Cabinet profiles are drawn to a common scale.
Vessel clearance.
Check internal dimensions and shelf positions against your vessels or trays.
Ambient conditions.
Ambient range: 5–30 °C. Recommended: 25 ±2 °C.
Power and gas.
Select 110 V or 220 V. Confirm the CO₂ supply and installation requirements.
Cycle requirements.
Review the moist heat procedure and accessory compatibility for your workflow.
Specifications
C80II and C160II. Select 110 V or 220 V.
Differs between models
| Model | C80II | C160II |
|---|---|---|
| Model and dimensions | ||
| SKU | C80II | C160II |
| Capacity | 80 L (2.82 cu ft) | 160 L (5.65 cu ft) |
| Internal size W × D × H (mm) | 368 × 452 × 517 mm | 468 × 552 × 648 mm |
| External size W × D × H (mm) | 611 × 773 × 841 mm | 711 × 873 × 991 mm |
| Packing size W × D × H (mm) | 725 × 887 × 985 mm | 820 × 1010 × 1128 mm |
| Net weight | 72 kg | 95 kg |
| Gross weight | 93 kg | 120 kg |
| Temperature and decontamination | ||
| Type | Air jacket | |
| Sterilization type | 90 °C moist heat sterilization | |
| Temperature sensor | PT100 | |
| Temperature range | RT+5 to 60 °C | |
| Temperature fluctuation | ±0.3 °C (at 37 °C) | |
| Temperature uniformity | ±0.5 °C (at 37 °C) | |
| Temperature precision | 0.1 °C | |
| CO₂ control | ||
| CO₂ sensor | IR infrared sensor with calibration certificate | |
| CO₂ range | 0–20 vol% | |
| CO₂ uniformity | 0.2 vol% | |
| CO₂ control resolution | 0.1 vol% | |
| Filter | CO₂ gas filter | |
| Sensor technology | Dual-channel, dual-filter infrared technology | |
| Controls, chamber and humidity | ||
| Display | 7-inch touch screen | |
| Timing range | 0–999 h or continuous | |
| Shelves | 2 pcs, adjustable | |
| Humidity display | Real-time humidity display | |
| Water reservoir | Bottom-mounted water reservoir | |
| Interior | 304 stainless steel, electrochemically treated; semicircular inner corners | |
| Temperature control | PID control | |
| Electrical and operating environment | ||
| Power consumption | 650 W | 700 W |
| Voltage | 110 V or 220 V | |
| Ambient temperature | 5–30 °C (recommended 25±2 °C) | |
| Accessories and protection | ||
| Standard accessories | Shelves, USB interface, CO₂ relief valve, CO₂ gas filter | |
| Optional accessories | Water pump, three-way connector | |
| Temperature alarms | Over-temperature and under-temperature alarms | |
| CO₂ alarms | Over-concentration and under-concentration alarms | |
| Water-level alarm | Low-water-level alarm | |
| Electrical protection | Leakage-current and over-voltage protection | |
Dimensions: width × depth × height. CO₂ values: volume percent (vol%). Amber markers indicate model-dependent values.
Operating conditions. RT = room temperature. Incubation: RT + 5 °C to 60 °C. Decontamination: 90 °C. Temperature fluctuation and uniformity are specified at 37 °C. Humidity is monitored; an active RH control range is not specified.
Configuration and
accessories.
Select the capacity and voltage above. Optional accessories are specified separately.
Standard equipment
- Two adjustable shelves
- USB interface
- CO₂ relief valve
- CO₂ gas filter
Optional accessories
- Water pump
- Three-way connector
Specify optional items when ordering.
Application and installation support.
Confirm culture conditions, CO₂ supply and cycle compatibility. Request model-specific operating documents before installation.
Technical questions.
Operating limits and configuration at a glance.
What does RT + 5 °C mean?
RT is room temperature. The lower incubation limit is 5 °C above ambient: 30 °C at a room temperature of 25 °C. The upper limit is 60 °C.
Is 90 °C used during incubation?
90 °C is used for the separate moist heat decontamination cycle. Routine incubation operates at RT + 5 °C to 60 °C.
What do the CO₂ specifications mean?
CO₂ range: 0–20 vol%. Control resolution: 0.1 vol%. Uniformity: 0.2 vol%. The infrared sensor is supplied with a calibration certificate.
Is humidity actively controlled?
Humidity is displayed in real time. A bottom water reservoir and low-water-level alarm are included; an active RH control range is not specified.
What should I confirm before ordering?
Confirm 80 L or 160 L, 110 V or 220 V, installation dimensions and CO₂ supply. Specify the optional water pump or three-way connector if required.
What does the warranty cover?
A 2-year warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded.
Can I return it?
Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.
How is it delivered, and when does it ship?
Freight, duties and taxes are paid to your loading dock; moving the incubator inside is not included. Your confirmed ship date is included in the order acknowledgement.
Can I get a formal quote for a purchase order?
Yes. Select your model and options, then click Get a quote for a PDF quotation with DDP shipping included.
Choose volume and voltage
The price and PDF quote update with your choices.