Biological Safety Cabinet

LORDERAN NSF 49 Certified Class II A2 Biosafety Cabinet with 99.9995% ULPA Filter, Electric Motorized Sash Laboratory Hood

SKU
BSC-3FA2-GL(3')
Availability
In stock
Questions

Ask about this instrument

LORDERAN NSF 49 Certified Class II A2 Biosafety Cabinet with 99.9995% ULPA Filter, Electric Motorized Sash Laboratory Hood

An engineer replies by email or phone, usually within 12 hours.

Size · 3FA2-GL(3')
Liftgate Delivery Service · No Need

A Class II A2 biological safety cabinet certified to NSF/ANSI 49, for clinical, microbiology and cell-culture work. Two ULPA filters at 99.9995% efficiency at 0.12 μm, a motorized front window, and 3, 4 and 6 ft widths. GL models read airflow in m/s; NA models read it in FPM for North American labs.

NSF 49Class II A2
99.9995%ULPA at 0.12 μm
3 · 4 · 6 ftcabinet widths
10°slanted front
ECMspeed-adjustable DC motor
Clinical diagnosticsCell and tissue cultureMicrobiologyVirology researchPharmaceutical QC

GL or NA?

Same cabinet and specifications. GL displays airflow in m/s, NA in FPM.

Do I need a duct?

No. About 40% of the air leaves through the exhaust ULPA filter; the rest is recirculated.

Does protection drop as the filter loads?

No. The fan speed adjusts automatically as the filter loads, so airflow holds over filter life.

What is the liftgate option?

A liftgate delivery service for docks without a forklift. Choose it in the configurator.

NSF/ANSI 49 Class II A2 Biosafety Cabinet datasheet (6 pages)

Full specifications, airflow and HEPA filtration, cabinet classes, ISO cleanliness, installation and warranty in one document to share with your team.
Download datasheet

Three directions of protection in one airflow

Room air enters at the front grille and forms a barrier for the operator. ULPA-filtered air falls over the work zone to keep samples clean. About 40% of the air leaves through the exhaust ULPA filter, so nothing leaves the cabinet unfiltered.

ULPA supply filterRoom air in: inflow 587 m³/hULPA-filtered downflow 863 m³/h40% exhausted via ULPA · 60% recirculated

Airflow volumes shown for BSC-4FA2-GL / NA. BSC-4FA2(4') runs a 65% / 35% split.

254 mmtested opening, GL / NA
550 mmmax opening, 4 and 6 ft
≥ 1000 LuxLED illumination
≤ 0.10 Ωground resistance
  • Air speed adjusts automatically as the filter loads, so protection stays constant over filter life.
  • Alarms for abnormal airflow velocity, filter replacement and unsafe window height.
  • Interlocks between UV lamp and window, UV lamp and blower or lamp, and blower and window.
  • Settings are kept in memory through a power failure.

Work at the tested opening

The protective air curtain is set and tested with the front window at 254 mm. Open it wider only to load or clean; the controller sounds an alarm when the window is above the safe height. The UV lamp runs only with the window closed.

ULPAUV on254 mm550 mmAlarmWork at 254 mm (10 in)Inflow is tested here: 0.53 m/sRaise to 520–550 mm to load or cleanAlarm sounds above the safe heightClose it for UVUV lamp is interlocked with the windowULPAUV on254 mm550 mmAlarmWork at 254 mm (10 in)Inflow is tested here: 0.53 m/sRaise to 520–550 mm to load or cleanAlarm sounds above the safe heightClose it for UVUV lamp is interlocked with the window

BSC-4FA2(4') is tested at 200 mm (8 in) and runs a 65% / 35% split.

Where the airflow figure comes from

Air enters through the front opening at the inflow speed, and the same volume leaves through the exhaust ULPA filter. Opening area × speed gives about 441 m³/h for the 3' GL / NA, the figure in the specifications.

interior width 910 mm254 mmfront windowtested opening 254 mm, air drawn in at 0.53 m/sOpening0.91 m × 0.254 m = 0.231 m²× inflow speed0.53 m/s = 0.1225 m³/s× 3600 s per hour≈ 441 m³/hListed for 3' GL / NA441 m³/hinterior width 910 mmfront windowtested opening 254 mm, air drawn in at 0.53 m/sOpening0.91 m × 0.254 m = 0.231 m²× inflow speed0.53 m/s = 0.1225 m³/s× 3600 s per hour≈ 441 m³/hListed for 3' GL / NA441 m³/h

The same calculation reproduces the listed airflow for every width.

Pick the width your bench needs

All four models share the same depth, 750 mm work surface height, airflow design and controls. Width sets how many people and how much equipment fit inside.

3'1087 mm910 mm inside4'1383 mm1210 mm inside6'1873 mm1700 mm inside3'1087 mm wide910 mm inside4'1383 mm wide1210 mm inside6'1873 mm wide1700 mm inside

External width and height drawn to scale.

Model 3' 4' 6'
External W 1087 mm 1383 mm 1873 mm
Internal W 910 mm 1210 mm 1700 mm
Inflow 441 m³/h 587 m³/h 824 m³/h
UV lamp 20 W 30 W 40 W
Power 400 W 500 W 700 W

4' values shown for the GL / NA model.

Comfortable for long sessions

The front is slanted 10° to cut glare and bring the work zone closer, and the motorized window moves at the touch of a button.

Control

  • Large LCD display with all information on one screen
  • Motorized front window
  • Automatic air speed adjustment as the filter loads
  • Power-failure memory function
  • GL reads velocity in m/s, NA reads it in FPM

Safety

  • Two ULPA filters, 99.9995% at 0.12 μm, with filter life indicator
  • Alarm for airflow, filter replacement and window height
  • UV lamp, blower, lamp and window interlocks
  • Germicidal UV lamp at 253.7 nm
  • Ground resistance ≤ 0.10 Ω

Build

  • Side and back walls in single-piece 304 stainless steel
  • Front slanted 10° for comfort and reach
  • Laminated toughened glass ≥ 5 mm, anti-UV
  • Water tap, gas tap and two waterproof sockets
  • Stainless steel I.V. bar with 10 hooks

Specifications

GL models display airflow velocity in m/s, NA models in FPM. Each GL / NA pair shares the same specifications.

Differs between models

Model BSC-4FA2(4') BSC-3FA2-GL / NA (3') BSC-4FA2-GL / NA (4') BSC-6FA2-GL / NA (6')
Dimensions
External Dims (W × D × H) 1383 × 775 × 2295 mm 1087 × 775 × 2265 mm 1383 × 775 × 2295 mm 1873 × 775 × 2295 mm
Internal Dims (W × D × H) 1210 × 600 × 660 mm 910 × 600 × 660 mm 1210 × 600 × 660 mm 1700 × 600 × 660 mm
Work Surface Height 750 mm
Max Opening 550 mm (22 in) 520 mm (20.5 in) 550 mm (22 in) 550 mm (22 in)
Tested Opening Safety height 200 mm (8 in) Safety height 254 mm (10 in) Safety height 254 mm (10 in) Safety height 254 mm (10 in)
Gross Weight 340 kg 270 kg 340 kg 370 kg
Package Size (W × D × H) 1540 × 1080 × 1900 mm 1220 × 1080 × 1840 mm 1540 × 1080 × 1900 mm 2020 × 1080 × 1900 mm
Airflow and filtration
Airflow Volume (Inflow) 462 m3/h(272cfm) 441 m3/h(259cfm) 587 m3/h(346cfm) 824 m3/h(485cfm)
Airflow Volume (Down flow) 65%:863 m3/h(507cfm) 60%:649 m3/h(382cfm) 60%:863 m3/h(507cfm) 60%:1212 m3/h(713cfm)
Airflow Volume (Exhaust) 35%:462 m3/h(272cfm) 40%:445 m3/h(259cfm) 40%:587 m3/h(346cfm) 40%:824 m3/h(485cfm)
ULPA Filter Two, 99.9995% efficient at 0.12 μm. Filter life indicator.
Filter Guard Type Aluminum alloy frame
DC Motor One ECM motor, 110 V& 220 V acceptable, Speed adjustable, high efficiency and low power consumption
Cabinet
Front Window Motorized. Two-layer laminated toughened glass ≥ 5 mm. Anti UV
Noise ≤ 67 dB
Illumination ≥ 1000 Lux
Display LCD Display
Alarm Abnormal airflow velocity; Filter replacement; Front window at unsafe height.
UV Lamp 30 W 20 W 30 W 40 W
UV Emission Germicidal UV lamp, Emission of 253.7 nanometers for most efficient decontamination
Illuminating Lamp 18 W*2 LED lamp 10 W*2 LED lamp 18 W*2 LED lamp 22 W*2 LED lamp
Tap Water tap*1, Gas tap *1
Material Working area: 304 stainless steel/ Frame and Decorative Plate: cold-rolled steel with anti-bacteria power coating
Electrical
Waterproof Socket 2, Total consumption:≤ 500 W
Ground Resistance ≤ 0.10Ω
Power Supply AC220 V±10%, 50/60 Hz; 110 V±10%, 60 Hz, Full load Amps: 9 A, BTU/Hr: 1689
Consumption 500 W 400 W 500 W 700 W
Accessories
Standard Accessory Illuminating lamp, UV lamp*2, Base stand, SS water & gas taps, Drain valve, Waterproof sockets, Stainless Steel I.V. Bar with 10 hooks
Optional Accessory Armrest, Airflow tester, Formalin fumigation sterilizer, Infrared sterilizer, Electric height adjustable base stand, Remote control

Questions buyers ask

Warranty, returns, delivery and quotes.

When can the UV lamp run?

Between sessions, to disinfect exposed surfaces. The UV lamp is interlocked with the window and with the blower and lamp.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. ULPA and HEPA filters, seals and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the cabinet inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose width and delivery

The price and PDF quote update with your choices.

Configure yours