Sample Preparation
Biological Safety Cabinet
Laminar Flow Cabinet
Fume Hood
Freeze Dryer
Steam Sterilizer
Vertical Pressure Steam Sterilizers
Lab Shaker
Open Air Shaker
Stackable Shaker
Floor Model Shaker
Test Chamber
Tablet Testing
Warranty
Support
FAQ
Blog
My Wish List




Free shipping on all orders (Door to Door)
We can ship to worldwide. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
Learn more from our shippling policy https://www.lorderan.com/policies/shipping-policy
Learn more from our warranty policy: https://www.lorderan.com/pages/warranty-policy
You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).
You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper, the time it takes us to process your return once we receive it, and the time it takes your bank to process our refund request (3 to 5 business days).
If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item. Learn more from our refund policy https://www.lorderan.com/policies/refund-policy
Delivered duty paid (DDP Term) shipping is a type of delivery where Lorderan paying for all charges including freight, duties, taxes, customs clearance charges up to the customer's door, warehouse or fulfillment center.
Bioproduct Storage
Simulating and verifying the sensitivity of biological samples, vaccines, reagents, etc., to environmental conditions and assessing long-term storage requirements.
Stability Testing
Evaluate the storage duration and shelf life of active pharmaceutical ingredients (APIs) and finished drug products under specific temperature and humidity conditions
Material Testing
Assessing the durability and physicochemical properties of materials, verify the reliability of products under various climatic conditions.
Shelf-Life Testing
By setting the temperature and humidity higher than normal storage conditions, the degradation process of the food is accelerated, allowing for the prediction of long-term shelf life in a short period.
Stable Damp Heat Working Zone
Temperature Range 0°C~100°C
Temperature Fluctuation ±0.5℃
Temperature Deviation/Uniformity ±1.5℃
Humidity Range RH 20%- RH 98%
Humidity Fluctuation ±2%RH
Humidity Deviation/Uniformity ±3%RH
Tips:
If required test conditions exceed the chamber's guaranteed stable range, kindly contact our technical support team to verify feasibility.
Environmental adaptability, reliability, and stability testing
Constant Temperature and Humidity Chamber is an essential tool in quality control, product development, and certification testing. It ensures that products meet the anticipated standards for quality, safety, and service life by providing a precise, controllable, and repeatable environment before they are released to the market.
The Constant Temperature and Humidity Chamber is more than just an incubator; it is a precision environmental control instrument essential for ensuring product compliance, reliability, and safety by providing a highly controlled, verifiable, and uniform simulated environment.
Structural Features
Internal Construction:SUS 304B stainless steel
Inner lining for excellent resistance to acids and corrosion, ensuring long-term durability and simplified cleaning.
Optimized air duct system
Guarantees superior temperature and humidity uniformity throughout the testing space.
Automatic water refill system
Equipped with water recirculation system, the water circulation tank serves as a reservoir for the humidification system. It ensures a stable water supply, preventing the humidification process from being interrupted, even when a large volume of steam is needed to rapidly increase humidity.
Variable Frequency Compressor
Adjusts its running frequency and power based on actual load requirements, avoiding the high energy consumption caused by frequent starting and stopping at full speed.
Core Energy-Saving Technologies
Lower Power Requirements
150L, 1.5kw, 6.8A (220V) / 13A(110V)
250L, 1.5kw, 6.8A (220V) / 13A(110V)
500L, 2.5kw, 11.4A(220V) / 22A(110V)
1000L, 2.5kw, 11.4A(220V) / 22A(110V)
Lower instantaneous peak current demands, making it easier to use with standard laboratory power outlets and avoiding costly circuit upgrades or specialized heavy-duty wiring.
Low-power models,allow to be easily deployed in locations with limited infrastructure (on standard 110V or 220V single-phase power).
High-Efficiency Thermal/Insulation Material
Uses thicker insulation layers with low thermal conductivity to minimize heat exchange and reduce the load on the cooling and heating systems.
Reduced Operating Costs
Lower power consumption means the equipment uses less electricity during operation. This is especially valuable for laboratories requiring long-term, continuous operation (e.g., ICH Stability Testing), leading to significant savings on utility bills.
Safety Features
Compressor overload protection
Shut down the compressor when its current draw exceeds safe limits, preventing motor damage due to high pressure or electrical faults.
Humidification heater dry-burn protection
Automatically cuts power to the humidification heating element if the water level in the reservoir drops below a safe minimum, preventing the heater from overheating and failing.
Over-temperature protection (OTP)
Shut down all heating elements and possibly cooling systems when the internal chamber temperature exceeds a defined high limit, preventing damage to the test samples and the chamber itself.
Electrical short circuit protection
Instantly interrupt the flow of electricity in the event of a short circuit, preventing electrical hazards and equipment damage.
HWS150
HWS250
HWS500
HWS1000
600*405*620mm
600*500*830mm
800*700*900mm
1000*1000*1000mm
830*800*1500mm
830*900*1700mm
1030*960*1790mm
1230*1400*1850mm
0~100℃
0~100℃
0~100℃
0~100℃
20~98% RH
20~98% RH
20~98% RH
20~98% RH
±0.5℃
±0.5℃
±0.5℃
±0.5℃
±2%RH
±2%RH
±2%RH
±2%RH
±1.5℃
±1.5℃
±1.5℃
±1.5℃
±3.0%RH
±3.0%RH
±3.0%RH
±3.0%RH
High-efficiency direct cooling
High-efficiency direct cooling
High-efficiency direct cooling
High-efficiency direct cooling
Hermetic compressor
Hermetic compressor
Hermetic compressor
Hermetic compressor
Air cooled
Air cooled
Air cooled
Air cooled
Platinum resistance PT100
Platinum resistance PT100
Platinum resistance PT100
Platinum resistance PT100
Touch Screen
Touch Screen
Touch Screen
Touch Screen
2
2
2
2
1.5kw
1.5kw
2.5kw
2.5kw
170kg
190kg
320kg
400kg
R290
R290
R290
R290
HWS150
600*405*620mm
830*800*1500mm
0~100℃
20~98% RH
±0.5℃
±2%RH
±1.5℃
±3.0%RH
High-efficiency direct cooling
Hermetic compressor
Air cooled
Platinum resistance PT100
Touch Screen
2
1.5kw
170kg
R290
HWS250
600*500*830mm
830*900*1700mm
0~100℃
20~98% RH
±0.5℃
±2%RH
±1.5℃
±3.0%RH
High-efficiency direct cooling
Hermetic compressor
Air cooled
Platinum resistance PT100
Touch Screen
2
1.5kw
190kg
R290
HWS500
800*700*900mm
1030*960*1790mm
0~100℃
20~98% RH
±0.5℃
±2%RH
±1.5℃
±3.0%RH
High-efficiency direct cooling
Hermetic compressor
Air cooled
Platinum resistance PT100
Touch Screen
2
2.5kw
320kg
R290
HWS1000
1000*1000*1000mm
1230*1400*1850mm
0~100℃
20~98% RH
±0.5℃
±2%RH
±1.5℃
±3.0%RH
High-efficiency direct cooling
Hermetic compressor
Air cooled
Platinum resistance PT100
Touch Screen
2
2.5kw
400kg
R290