Dissolution Tester

LORDERAN Auto-Lifting Dissolution Tester, USP EP Compliant Tablet Dissolution Apparatus for Pharmaceutical Lab

SKU
RC-6D
Availability
In stock
Questions

Ask about this instrument

LORDERAN Auto-Lifting Dissolution Tester, USP EP Compliant Tablet Dissolution Apparatus for Pharmaceutical Lab

An engineer replies by email or phone, usually within 12 hours.

Model · RC-6D

Dissolution testing on six to twelve stations with an auto-lifting head, so all vessels start together. Basket or paddle, 20 to 200 rpm, ±0.3 °C bath and 9 preset sampling times with a beep at each; the RC-12D adds self-inspection alarms and over-temperature protection.

37.0 °C · 50 rpmT1 15 min T2 30 minAuto-lift±0.3 °C20–200 rpmBasket + paddle
6–8–12testing stations
20–200 rpmspeed, ±2 rpm
±0.3 °Ctemperature stability
5–900 minnine preset time points
SUS316 Lbasket and paddle
Pharmaceutical QCR&D formulationGeneric drug developmentUniversitiesNutraceuticals

Basket or paddle?

Both: basket and paddle units in imported SUS316L. Use the apparatus your monograph specifies.

How many sampling points?

9 preset times from 5 to 900 min; the tester beeps at each and moves on to the next.

How stable is the bath?

Room temperature to 45 °C, held within ±0.3 °C by magnetically driven water circulation.

Which power does it need?

220 V / 50 Hz or 110 V / 60 Hz. Stations: 6, 8 or 12.

RC-6D to RC-12D Auto-Lifting Dissolution Tester datasheet (5 pages)

Full specifications, USP <711> reference and acceptance criteria, installation and warranty in one document to share with your team.
Download datasheet

Basket or paddle, nine points to a profile

Each vessel sits in a water bath heated evenly by magnetically driven circulation. Tablets dissolve under a rotating basket or paddle, and you sample at up to nine preset times to build the dissolution profile.

BasketSUS316LPaddleSUS316LWater bath, Rt to 45 °C, ±0.3 °C25%50%75%100%T1T2T3T4T5T6T7T8T9Nine preset time points, 5 to 900 min, with a beep at each% dissolvedBasketSUS316LPaddleSUS316LBath: room temp.to 45 °C, ±0.3 °C20–200 rpm±2 rpm% dissolved9 preset times, 5–900 min
±0.5 mmpaddle radial run-out
±1.0 mmbasket radial run-out
Rt–45 °Cbath temperature
MPUtemperature, speed, time

How results are accepted

Results are judged against Q, the amount of active ingredient the monograph requires in solution by the stated time. For immediate-release forms USP <711> accepts in up to three stages, and each stage adds more vessels, so a six-station bath runs Stage 1 in a single pass.

S16 unitsEach unit not less than Q + 5 %S26 more, 12 in totalMean of 12 ≥ Q, and no unit below Q − 15 %S312 more, 24 in totalMean of 24 ≥ Q; not more than 2 units below Q − 15 %, none below Q − 25 %S16 unitsEach unit not less than Q + 5 %S26 more, 12 in totalMean of 12 ≥ Q;and no unit below Q − 15 %S312 more, 24 in totalMean of 24 ≥ Q;not more than 2 units below Q − 15 %;none below Q − 25 %

Summary of the USP <711> acceptance table for immediate-release dosage forms. Your monograph defines Q and the time point.

Specifications

Models RC-6D, RC-8D, RC-8DS and RC-12D. 220 V / 50 Hz or 110 V / 60 Hz.

Differs between models

Model RC-6D RC-8D RC-8DS RC-12D
Testing
Testing Station 6 6 8 12
Speed Range 20 to 200 rpm
Speed Accuracy ±2 rpm
Temperature Range Rt to 45.0°C
Temperature Stability ±0.3°C
Preset Timing Nine Points 5 to 900 min
Time Accuracy ±0.5 min
Paddle Radial Run-Out ±0.5 mm
Basket Radial Run-Out ±1.0 mm
Instrument
Power Supply 220 V/ 50 Hz, 110 V/ 60 Hz
Power 1200 W
Dimension 960×400×480 mm 960×520×480 mm 680×540×480 mm 900×550×550 mm

Designed for reproducible results

Stable temperature, true rotation and simple operation.

Even bath heating

Magnetically driven water circulation brings every vessel to the same temperature.

Microprocessor control

Temperature, speed and time preset at any time; preset and live values alternate on screen.

Nine time points

Preset up to nine sampling times; the tester beeps and moves to the next.

SUS316L basket and paddle

Imported stainless steel for corrosion resistance and accuracy.

Automatic lifting head

The head raises and lowers itself.

Auto-test, diagnose, alarm

The tester checks itself and warns of faults.

RC-12D: 12 vessels

185 mm high vessels, optional amber vessels, software temperature offset.

Protection and memory

Over-temperature protection and parameters saved between sessions (RC-12D).

Explore the LORDERAN tablet testing range

Hardness, friability, disintegration and dissolution, as single instruments or combined.

Series
RC-D seriesThis product
Head
Turn over by hand
Turn over by hand
Automatic lifting
Automatic lifting, turn over by hand
Stations
1 or 3
6 (RC-8: 6 + 2 media)
6, 8 or 12
3, 6 or 8
Standards stated
USP, EP
ChP 2020 parameters
USP, EP; ChP 2020 parameters
USP, EP, ChP

Questions buyers ask

Methods, warranty, returns, delivery and quotes.

What does the warranty cover?

A 1-year warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Glassware, seals and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the tester inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose your model

The price and PDF quote update with your choice.

Configure yours