A laboratory autoclave for media, glassware and waste, with a programme for every load: solid, liquid, agar melting and a custom mode. Exhaust steam and air are condensed in a built-in bottle, so nothing is vented into the lab. Drying, keep-warm, a built-in printer and calibration ports come as standard. Four sizes from 35 to 100 L; the 75L and 100L need 220 V.
Can it melt agar?
Yes. Mode M3 melts agar at 60 to 100 °C, then holds it at 45 to 60 °C so it does not set before you pour.
How does it handle liquids?
Mode M2 uses a slower exhaust to prevent boil-over in media and solutions.
Will steam escape into the lab?
No. Steam and air are condensed in the built-in bottle.
Can I validate it?
Temperature and pressure calibration ports take 3Q IQ/OQ/PQ adapters, and the built-in printer records each cycle.
35–100 L Lab Autoclave with Condensate Bottle datasheet (6 pages)
Full specifications, the sterilization cycle, saturated steam and F0 reference values, installation and warranty in one document to share with your team.Download datasheetOne autoclave, four programmes
Pick the mode for the load. The controller handles exhaust speed, timing and holding temperature.
Why it runs under pressure
Water boils at 100 °C at normal air pressure. To reach 121 °C or 134 °C, steam has to be held above atmospheric pressure, which is why the chamber is a pressure vessel. Air has to be removed first: an air and steam mixture at the same pressure is cooler than pure steam. At 134 °C the steam needs about 0.20 MPa, below the 0.24 MPa this unit is rated for.
Saturated steam pressure calculated with the IAPWS-IF97 equations, shown above atmospheric pressure (gauge). Pure steam with all air removed.
Specifications
Models N-35X, N-50X, N-75X and N-100X, each available in 110 V and 220 V versions.
Differs between models
| Model | 35 L | 50 L | 75 L | 100 L |
|---|---|---|---|---|
| Model | ||||
| SKU | N-35X | N-50X | N-75X | N-100X |
| Performance | ||||
| Working pressure | 33psi (0.23mpa) | |||
| Max temperature | 134 °C | |||
| Temp. setting range | 106 to 134 °C (222.8 to 273°F) | |||
| Heat average | ≤ 0.5 °C | |||
| Sterilization timer range | 1 to 999mins | |||
| Drying timer range | 0 to 240mins | |||
| Chamber and loading | ||||
| Inner chamber capacity | φ300x450 mm | φ350x515 mm | φ400x585 mm | φ450x615 mm |
| Baskets quantity | 1*(φ275x395 mm) | 2*(φ325x235) | 2*(φ375x265) | 2*(φ425x275) |
| Operation | ||||
| Exhaust method | Automatic internal exhaust | |||
| Drainage | Manual drainage | |||
| Electrical | ||||
| Power | 2.5 kW, 12amps(220 V), 21amps (120 V) | 3 kW, 13.6amps(220 V), 25amps (120 V) | 4.5 kW, 20.5amps(220 V), 37.5amps (120 V) | 4.5 kW, 20.5amps(220 V), 37.5amps (120 V) |
| Dimensions and weight | ||||
| Overall dimensions | 430x610x1030 mm | 500x675x1100 mm | 540x716x1165 mm | 575x748x1255 |
| G.W / N.W | 90/74 kg | 125/97 kg | 145/114 kg | 161/129 kg |
Key technical parameters
The controller settings, as listed for this autoclave.
Show all 15 parameters: temperatures, times and exhaust
Choose a size
Same modes and safety on every size. Drawn to the same scale; the dashed outline is the inner chamber.
Made for unattended, mess-free work
Load in the evening, find sterile media and molten agar ready in the morning.
Zero steam emission
No steam is vented into the lab during air removal or depressurization.
Built-in condensate bottle
Exhausted steam and air condense back into water inside the unit.
Keep warm 45–60 °C
Holds the load warm automatically after sterilization.
Standard drying
0 to 240 minutes to reduce residual moisture.
Multi-stage exhaust
Set exhaust interval, time and number of pulses.
Built-in printer
A printed record of every cycle.
Calibration ports
Temperature and pressure ports compatible with 3Q IQ/OQ/PQ adapters.
Safety interlock
With memory storage and downward internal steam circulation.
Find the right LORDERAN autoclave
Compare the range by capacity, exhaust and special functions.
Questions buyers ask
Warranty, returns, delivery and quotes.
What does the warranty cover?
A 1-year warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded.
Can I return it?
Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.
How is it delivered, and when does it ship?
Freight, duties and taxes are paid to your loading dock; moving the autoclave inside is not included. Your confirmed ship date is included in the order acknowledgement.
Can I get a formal quote for a purchase order?
Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.
Choose size and voltage
The price and PDF quote update with your choices.