Constant Temperature and Humidity Test Chamber

LORDERAN Temperature Humidity Test Chamber 0-100°C, 20-98% RH, Water Recirculation, for Electronics & Material Testing, HWS Series

SKU
HWS150
Availability
In stock
Questions

Ask about this instrument

LORDERAN Temperature Humidity Test Chamber 0-100°C, 20-98% RH, Water Recirculation, for Electronics & Material Testing, HWS Series

An engineer replies by email or phone, usually within 12 hours.

Capacity · 150L
Power · 110V

Long, steady temperature and humidity tests: stability studies, shelf-life testing, material conditioning and bioproduct storage, at 0 to 100 °C and 20 to 98 %RH, in four sizes from 150 to 1000 L. Humidity is controlled from 15 to 85 °C, and the lowest humidity you can reach rises as the temperature falls, so check the control range chart for your conditions.

ICH 40/75, held40.0 °C104 °F at 75 %RHDay 1Day 30Day 90Day 180steady, ±0.5 °CICH 25/60ICH 30/65ICH 40/75Water refills itselfICH 40/75, held40.0 °C75 %RHDay 1Day 30Day 90Day 180ICH 25/60ICH 30/65ICH 40/75
0–100 °Ctemperature range
20–98 %RHhumidity range
±0.5 °Ctemperature fluctuation
±2 %RHhumidity fluctuation
150–1000 Lfour sizes
Stability testingShelf-life testingMaterial testingBioproduct storageElectronics

Will it run ICH conditions?

Yes. 25 °C / 60 %RH, 30 °C / 65 %RH and 40 °C / 75 %RH all sit inside the controlled zone, held for months.

How often do I add water?

Rarely. Condensate and unused water are pumped back to the humidifier, and a refill bottle tops up the loop.

Which voltage should I order?

Each size comes in 110 V and 208–240 V versions. At 220 V: 6.8 A for 150 and 250 L, 11.4 A for 500 and 1000 L.

Can it cool below room temperature?

Yes, down to 0 °C with humidity off. Humidity is controlled from 15 to 85 °C; see the chart.

Constant Temperature and Humidity Test Chamber documentsThe datasheet puts all four sizes and specifications on one sheet for your team. The user manual covers installation, operation, water care and safety.Download datasheet Download user manual

How it holds one condition for months

Air circulates through a duct beside the workspace; water circulates through a loop below it.

WorkspaceAir ductFanEvaporator, direct coolingHeaterHumidifier panComp.Inverter compressor, R290Water box + pumpWater bottle, auto refillTouch screenActual40.0 °C75.0 %RH1234Touch screenActual40.0 °C75.0 %RHWorkspaceAir ductFanEvaporatorHeaterHumidifierComp.InvertercompressorWater box+ pumpBottle,auto refill1234

Simplified section, not to scale; part positions are schematic. Screen values are an example.

  1. 1
    Load the samples.Two racks as standard. A 100 mm test hole takes cables to powered samples.
  2. 2
    Set the condition.Temperature and humidity on the touch screen; a PT100 platinum sensor reads the temperature.
  3. 3
    Condition the air.The fan drives air through the duct: the evaporator cools and dries it, the heater warms it, the humidifier adds moisture. It leaves evenly across the shelves.
  4. 4
    Reuse the water.Condensate and unevaporated water are collected and pumped back to the humidifier, and a refill bottle tops up the loop automatically. If water runs low, the humidifier heater switches off.

The stable damp-heat working zone

Temperature runs from 0 to 100 °C. Where temperature and humidity are controlled together, the chamber holds the coloured zone steadily for weeks. The three markers are the ICH stability conditions used in pharmaceutical stability programs; all three sit well inside the zone.

01020304050607080901000102030405060708090100Temperature (°C)Relative humidity (%RH)Temperature only: 0 to 100 °CCONTROLLED T + H ZONEhumidity controlled, 15 to 85 °C15 °C · 98 %60 °C · 98 %85 °C · 90 %85 °C · 20 %60 °C · 20 %Long-term 25/60Intermediate 30/65Accelerated 40/7501020304050607080901000102030405060708090100982025/6030/6540/75%RHTemperature (°C)
Controlled temperature and humidity zoneICH long-termICH intermediateICH accelerated
98 %RHacross the top of the zone from 15 to 60 °C, easing to 90 %RH at 85 °C.
20 %RHis reachable from 60 to 85 °C; at lower temperatures the minimum humidity rises, as the zone boundary shows.
Outside the zone?Conditions beyond the guaranteed range need a feasibility check. Ask our engineers before you order.

Specifications

Models HWS150, HWS250, HWS500 and HWS1000, in 110 V and 208–240 V versions.

Differs between models

Model 150 L 250 L 500 L 1000 L
Model and size
SKU HWS150 HWS250 HWS500 HWS1000
Inner size (W × D × H) 600 × 405 × 620 mm 600 × 500 × 830 mm 800 × 700 × 900 mm 1000 × 1000 × 1000 mm
External size (W × D × H) 830 × 800 × 1500 mm 830 × 900 × 1700 mm 1030 × 960 × 1790 mm 1230 × 1400 × 1850 mm
Test Hole 100 mm*1
Racks 2
Weight 170 kg 190 kg 320 kg 400 kg
Temperature and humidity
Temperature range 0 to 100 °C
Humidity range 20 to 98 %RH
Temperature fluctuation ±0.5 °C
Humidity fluctuation ±2 %RH
Temperature deviation ±1.5 °C
Humidity deviation ±3.0 %RH
Refrigeration, control and power
Refrigeration method High-efficiency direct cooling
Compressor Hermetic compressor
Cooling method Air cooled
Refrigerant R290
Temperature sensor Platinum resistance PT100
Display Touch Screen
Power 1.5 kW 1.5 kW 2.5 kW 2.5 kW

Choose a size

Same range, controller and protection on every size. Front elevations drawn to the same scale.

150L · HWS150830 mm600×405×620 inside250L · HWS250830 mm600×500×830 inside500L · HWS5001030 mm800×700×900 inside1000L · HWS10001230 mm1000×1000×1000 insideHWS150830 × 1500 mmHWS250830 × 1700 mmHWS5001030 × 1790 mmHWS10001230 × 1850 mm

Ready for long-term stability studies

Typical ICH conditions for drug substances and products, all inside the controlled zone, held for months at low running cost.

Long-term25 °C / 60 %RH

Real-time stability at standard storage conditions.

Intermediate30 °C / 65 %RH

When accelerated results show a significant change.

Accelerated40 °C / 75 %RH

Faster degradation for early shelf-life estimates.

Long-term25 °C / 60 %RHIntermediate30 °C / 65 %RHAccelerated40 °C / 75 %RH061218243036monthsLong-term · 25 °C / 60 %RHIntermediate · 30 °C / 65 %RHAccelerated · 40 °C / 75 %RH061218243036months

Testing frequency for a product with a proposed shelf life of at least 12 months: every 3 months in year 1, every 6 months in year 2, then yearly (36 months shown). Intermediate: 4 time points over 12 months; accelerated: 3 over 6 months. The long-term condition alone keeps a chamber busy for years.

Conditions as commonly specified in ICH Q1A(R2). Your protocol defines the exact conditions and durations.

Water recirculation: weeks without refilling

Condensate and unevaporated water are collected and pumped back to the humidifier reservoir, for more than 80% better water utilization, less DI or RO water, no external drain line and unattended running for weeks or months.

ReservoirDI / RO waterHumidifiersteam to chamberTest chamberhigh-humidity testCondensatecollectedReturn pumpfiltered waterReturn linewater reusedOver 80% higher water utilizationReservoirDI / RO waterHumidifiersteam to the chamberTest chamberhigh-humidity testCondensatecollectedReturn pumpfiltered waterReturn linewater reusedAuto refillOver 80% higher water utilization

Engineered to run cheaply for months

What keeps running costs low, and the details that make long tests easier.

Variable-frequency compressor

Output follows the load instead of cycling at full speed, for steadier control and lower energy use.

Thicker insulation

Low-conductivity insulation reduces the work the heater and compressor must do.

Automatic water refill

A recirculation tank feeds the humidifier automatically.

Optimized air duct

Even airflow for better temperature and humidity uniformity.

SUS 304B interior

Acid- and corrosion-resistant stainless steel that wipes clean.

R290 refrigerant

A natural refrigerant, in an air-cooled hermetic system.

Touch screen, PT100

Clear touch control with a platinum resistance PT100 sensor.

100 mm test hole

Run cables to powered samples during the test.

Low current draw

Rated current by size and supply voltage, to plan the circuit with your facilities team. For a load that runs for days, keep it to 80% of the breaker rating.

80% of 15 A80% of 20 A80% of 30 A
150 L and 250 L at 220 V6.8 A
150 L and 250 L at 110 V13 A
500 L and 1000 L at 220 V11.4 A
500 L and 1000 L at 110 V22 A

Safety protection

The chamber protects itself, your samples and your lab.

Show all 4 safety protections
  • Compressor overload protection
  • Humidification heater dry-burn protection: power is cut when reservoir water is too low
  • Over-temperature protection: heating, and if needed cooling, shut down
  • Electrical short-circuit protection

Find the right LORDERAN environmental chamber

Steady climate, damp heat or fast ramps: choose by how your product must be tested.

Chamber
Constant T&H 0–100 °CThis product
Temperature
0 to 100 °C
−40 to 150 °C
−70 to 150 °C
60 to 100 °C
−70 to 150 °C
Humidity
20–98 %RH
20–98 %RH
20–98 %RH
80–98 %RH
20–98 %RH
Best for
Stability, shelf-life, storage
General climate testing
Climate testing down to −70 °C
Double 85 / Double 95
Stress screening, 5–15 °C/min
Sizes
150–1000 L
100–1000 L
100–1000 L
150–1000 L
100–1000 L

Questions buyers ask

Humidity limits, warranty, returns, delivery and quotes.

Which humidity is possible at which temperature?

See the control range chart: humidity is controlled from 15 to 85 °C, up to 98 %RH between 15 and 60 °C and 90 %RH at 85 °C; the minimum humidity rises at lower temperatures. Outside the zone, ask our engineers.

What does the warranty cover?

A 2-year warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the chamber inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose size and voltage

The price, delivery date and PDF quote update with your choices.

Configure yours