Environmental test chamber

LORDERAN Climate Chamber -40°C to 150°C, 20-98% RH, Temperature Humidity Test Chamber with Water Recirculation, IEC/ASTM, JS4 Series

SKU
JS4010
Availability
In stock
Questions

Ask about this instrument

LORDERAN Climate Chamber -40°C to 150°C, 20-98% RH, Temperature Humidity Test Chamber with Water Recirculation, IEC/ASTM, JS4 Series

An engineer replies by email or phone, usually within 12 hours.

Capacity · 100L

Cold, dry-heat and damp-heat tests for electronics, automotive parts and materials: −40 °C to +150 °C and 20–98 %RH, in four sizes from 100 to 1000 L.

Hold one condition for days, or program cycles that repeat on their own. Reachable humidity depends on temperature, so check your test point on the chart below before you order.

The picture runs three example set points; colors show the condition, not a camera view.

Set point−40.0 °C−40 °F, humidity off+85.0 °C185 °F, humidity off40.0 °C104 °F at 93 %RHColdColdDry heatDry heatDamp heatDamp heatSet point−40.0 °C−40 °F, humidity off+85.0 °C185 °F, humidity off40.0 °C104 °F at 93 %RHColdColdDry heatDry heatDamp heatDamp heat
−40 → 150 °Ctemperature range
20–98 %RHhumidity range, see chart
±0.5 °Ctemperature fluctuation
±2–3 %RHhumidity fluctuation
100–1000 Lfour sizes

Performance figures: empty chamber, +25 °C ambient.

Will it reach my humidity?

Every limit is on the humidity chart, taken from the user manual. Drier or cooler points need the low-humidity option in the configurator.

Do I need a water line?

No. A 20 L tank behind the rear cover feeds the humidifier, and condensate drips back into it. One fill lasts up to about 7 days.

Can it run overnight?

Yes. 100 programs of up to 100 segments, alarms on the screen and over the network, and a return to room temperature when the program ends.

Which power does it need?

100 and 250 L: 1-phase 208–240 V, or 3-phase. 500 and 1000 L: 3-phase only. Five 3-phase voltages from 208 to 480 V; all 50/60 Hz.

Datasheet and user manual (PDF)All four sizes and test standards on one sheet; the manual covers installation, programming, water and maintenance.Datasheet User manual

How it holds your test conditions

The samples sit in a sealed workspace. Everything that changes the air happens in a duct behind its back wall.

WorkspaceAir ductCable portSamples on shelvesComp.Refrigeration unit: compressor + air-cooled condenserFanCooling coil (evaporator)HeaterHumidifier, makes steamWater tank (rear)Dry- and wet-bulb sensorsTouch screenSet40.0 °C93 %RH12345Touch screenSet40.0 °C93 %RHWorkspaceAir duct, behind back wallCable portSamples on shelvesFanCooling coilHeaterHumidifierComp.Refrigeration unitcompressor + condenserWater tank(rear, 20 L)Dry- and wet-bulb sensors12345

Simplified section, not to scale. Part positions follow the user manual; blue arrows show the air path. Screen values are an example.

  1. 1
    Load the samples.Space them out on the shelves, keep the load under ¾ of the workspace, and run cables through the Ø100 mm side port.
  2. 2
    Set the test.Enter a set point (temperature, humidity, time) on the 7-inch touch screen, or pick a saved program.
  3. 3
    Condition the air.A fan pushes air through the duct: the cooling coil chills and dries it, the heater warms it, the humidifier adds steam.
  4. 4
    Measure and correct.A dry sensor and a wet-wick sensor read the air; the gap between them gives the humidity. The controller adjusts each part until actual matches set.
  5. 5
    End the test.The chamber returns to room temperature to protect the samples. Logged data exports to USB.

Can it reach your humidity at your temperature?

Relative humidity (%RH) compares the water vapor in the air with the most it can hold at that temperature, so the range the chamber can hold changes with temperature. Colored: standard. Hatched: needs the optional low-humidity function.

01020304050607080901000102030405060708090100Temperature (°C)Relative humidity (%RH)STANDARD ZONE20 to 98 %RHLOW-RHoptional10 °C · 98 %10 °C · 98 %20 °C · 98 %20 °C · 98 %70 °C · 98 %70 °C · 98 %90 °C · 90 %90 °C · 90 %20 °C · 55 %20 °C · 55 %45 °C · 20 %45 °C · 20 %90 °C · 20 %90 °C · 20 %10 °C · 50 %10 °C · 50 %20 °C · 30 %20 °C · 30 %30 °C · 18 %30 °C · 18 %40 °C · 10 %40 °C · 10 %90 °C · 10 %90 °C · 10 %020406080100020406080100Standard range20–98 %RH98 %RH from 20 to 70 °C90 %55 %20 % from 45 °C10 % from 40 °C, optionLow-RH option%RHTemperature (°C)
Standard zoneLow-humidity zone, optional low-humidity function
98 %RHfrom 20 to 70 °C, easing to 90 %RH at 90 °C.
20 %RHstandard lower limit from 45 to 90 °C, rising toward 55 %RH at 20 °C.
10 %RHfrom 40 °C with the low-humidity function, also needed for any humidity test at 10–20 °C. Outside 10–90 °C: temperature only.

Specifications

Performance figures: empty chamber, +25 °C ambient, clean condenser. Fluctuation is how far a reading swings around the set point once stable; deviation and uniformity compare points across the workspace.

Differs between models

Model 100 L 250 L 500 L 1000 L
SKU JS4010 JS4025 JS4050 JS4100
Interior, W × D × H 450 × 450 × 500 mm 600 × 600 × 700 mm 800 × 700 × 900 mm 1000 × 1000 × 1000 mm
Exterior, W × D × H, casters included 780 × 1130 × 1580 mm 960 × 1500 × 1760 mm 1130 × 1550 × 1950 mm 1320 × 1890 × 2050 mm
Shelves (standard) 2 2 3 3
Weight (approx.) 250 kg 320 kg 500 kg 680 kg
Noise level 60–65 dB 60–65 dB 65–70 dB 65–70 dB
Power supply (50/60 Hz) 1-phase: 208–240 V
3-phase: 208, 220–240, 400, 415 or 480 V
1-phase: 208–240 V
3-phase: 208, 220–240, 400, 415 or 480 V
3-phase: 208, 220–240, 400, 415 or 480 V 3-phase: 208, 220–240, 400, 415 or 480 V
Rated power 6 kW 7 kW 10 kW 13 kW
Rated current 27 A at 220 V, 1-phase 32 A at 220 V, 1-phase 27 A at 220 V
12 A at 480 V
34 A at 220 V
16 A at 480 V
Temperature and humidity, all sizes
Temperature range −40 to +150 °C
Humidity range 20–98 %RH (see chart)
Temperature fluctuation ±0.5 °C
Temperature deviation ≤ ±2 °C
Temperature uniformity ≤ 2 °C
Humidity fluctuation ±2–3 %RH
Humidity deviation ±2.0 %RH above 75 %RH
±3.0 %RH at 75 %RH or below
Humidity uniformity ≤ 5 %RH
Heating rate (average) 2–3 °C/min
Cooling rate (average) 0.7–1 °C/min
Heating-up time +20 °C to +150 °C in ≤ 60 min
Cooling-down time +20 °C to −40 °C in ≤ 70 min
Refrigeration, control and build, all sizes
Refrigeration Air-cooled, R449A
Controller 7-inch color touch screen, 100 programs × 100 segments
Interfaces USB (data and program export), RS-485 (PC monitoring and control)
Inner chamber and shell SUS304 stainless steel: 2 mm fully welded inner chamber, 1.5 mm outer shell
Insulation PU foam and rock wool
Door Double silicone seals, heated double-glazed window, interior light
Test port Ø100 mm with rubber plug, left side (custom ports on request)
Water tank 20 L, built in; RO or DI water

Which size fits your samples and your doorways?

Keep the samples to about ¾ of the workspace, with gaps between items and the walls. The drawing puts each size beside a standard 36 × 80 in door: the chamber travels upright, so check its narrowest side and its height against every doorway on the route.

Door914 × 2032 mm36 × 80 indoor height, 2032 mm / 80 in100 L780 × 1580 mm30.7 × 62.2 in✓ fits the door250 L960 × 1760 mm37.8 × 69.3 in✗ wider than door500 L1130 × 1950 mm44.5 × 76.8 in✗ wider than door1000 L1320 × 2050 mm52 × 80.7 in✗ wider and tallerDoor36 × 80 in100 L✓ fits250 L✗ wider500 L✗ wider1000 L✗ wider✗ taller

Exterior dimensions as published. Height includes the casters; packaging not included.

100 L

100 L · JS4010

Exterior
780 × 1130 × 1580 mmW × D × H, casters included
Interior
450 × 450 × 500 mm2 shelves as standard
Samples
up to about 75 L in total¾ of the workspace, with gaps
Weight
250 kg
Power
1-phase: 208–240 V
3-phase: 208, 220–240, 400, 415 or 480 V50/60 Hz
250 L

250 L · JS4025

Exterior
960 × 1500 × 1760 mmW × D × H, casters included
Interior
600 × 600 × 700 mm2 shelves as standard
Samples
up to about 190 L in total¾ of the workspace, with gaps
Weight
320 kg
Power
1-phase: 208–240 V
3-phase: 208, 220–240, 400, 415 or 480 V50/60 Hz
500 L

500 L · JS4050

Exterior
1130 × 1550 × 1950 mmW × D × H, casters included
Interior
800 × 700 × 900 mm3 shelves as standard
Samples
up to about 380 L in total¾ of the workspace, with gaps
Weight
500 kg
Power
3-phase: 208, 220–240, 400, 415 or 480 V50/60 Hz
1000 L

1000 L · JS4100

Exterior
1320 × 1890 × 2050 mmW × D × H, casters included
Interior
1000 × 1000 × 1000 mm3 shelves as standard
Samples
up to about 750 L in total¾ of the workspace, with gaps
Weight
680 kg
Power
3-phase: 208, 220–240, 400, 415 or 480 V50/60 Hz

Tap a size for its full dimensions, weight and power.

What to prepare before delivery

Power, room, water and access. The user manual has the details.

Power

Dedicated circuit with breaker and RCD sized to the rated current; earth ≤ 4 Ω.

Room

+5 to +32 °C, ≤ 85 %RH, ventilated, out of direct sun.

Floor

Level and rated for the chamber, 250 to 680 kg.

Clearance

40 to 80 cm around the chamber, plus room to open the door fully.

Water

RO or DI water only, ≤ 5 µS/cm. No tap water.

Drain

A floor drain, or a tray under the rear overflow.

Delivery

Duty-paid to your loading dock. Plan a forklift or pallet jack.

In the box

Shelves, USB stick, spare parts, door key and documents.

Which test profiles can you run?

A test is a list of set points: what to reach and how long to hold it. These are the three common kinds.

Temperature, left axisHumidity, right axis

Temperature onlyHumidity control off. Example: two cycles between 85 °C and −40 °C, with 1 h at each end.
-50050100°C04812Time (h)Humidity off
Constant temperature and humidityOne set point held for a long time. Example: 40 °C at 93 %RH for 96 h.
-50050100°C50100%RH024487296Time (h)
Programmed cycleTemperature and humidity change together, then repeat. Example: a 24 h cycle between 25 °C at 95 %RH and 55 °C at 93 %RH, run twice.
-50050100°C50100%RH012243648Time (h)

Set-point examples drawn for explanation, not measured chamber data. A program can’t ramp faster than the chamber: 2–3 °C/min up and 0.7–1.0 °C/min down on average, empty chamber at +25 °C ambient. Heavy, wet or heat-producing loads are slower.

What keeps a long test running

Named components, the build, and the protections behind an unattended test.

Tecumseh, Bitzer or GEA BOCK compressor

Overheat and over-pressure protection, vibration damping. R449A, air-cooled: no cooling water.

7-inch touch screen

100 programs × 100 segments, loops and a wait step. Data logs every 60 s and exports to USB as XLS.

Remote monitoring

Live curves, compressor status and alarms over the network. RS-485 for PC control.

Dry ceiling

Air circulation keeps the ceiling dry, so condensate doesn’t drip onto samples.

Auto-return

Back to room temperature when a program ends, to protect the samples.

Frost-free door seals

Double silicone seals, rated for more than 1000 hours of frost-free running.

SUS304 inside and out

2 mm fully welded inner chamber, 1.5 mm shell, PU foam and rock wool.

Heated window and cable port

Double glazing with an interior light. Ø100 mm port on the left; custom ports on request.

Show all safety protections
  • Sample over-temperature protection (controller)
  • Independent over-temperature protector
  • Compressor overload protection
  • Compressor over-pressure protection
  • Fan motor overload protection
  • Humidifier dry-burn protection
  • Water shortage protection
  • Phase loss and reversal protection
  • Short-circuit and earth-leakage protection
  • Three-color alarm light
  • Flame-retardant non-metallic materials
Show the reference standards: IEC 60068, GB/T, GJB150
IEC 60068-2-1 coldIEC 60068-2-2 dry heatIEC 60068-2-30 damp heat, cyclicIEC 60068-2-78 damp heat, steady stateGB/T 2423.1–2423.4GJB150.3 high temperatureGJB150.4 low temperatureGJB150.9 damp heat

Need colder, faster, or a thermal shock?

Pick by the stress your product has to survive: a steady climate, fast ramps, or a sudden hot-to-cold transfer.

Chamber
Climate −40 °CThis product
Temperature
−40 to 150 °C
−70 to 150 °C
−70 to 150 °C
−65 to 200 °C
Humidity
20–98 %RH
20–98 %RH
20–98 %RH
No
Rate of change
2–3 °C/min up, 0.7–1 °C/min down
2–3 °C/min up, 0.7–1 °C/min down
5, 10 or 15 °C/min
Zone transfer within 15 s
Sizes
100–1000 L
100–1000 L
100–1000 L
50–200 L
Choose it when
Climate tests down to −40 °C
You need to go below −40 °C
You need 5–15 °C/min ramps
You need hot-to-cold transfer within 15 s, no humidity

Questions before you order

Options, water, delivery, warranty, returns and quotes.

Do I need the low-humidity function?

Only if a test point falls in the hatched zone of the humidity chart: below 20 %RH (down to 10 %RH from 40 °C), below the standard lower limit between 20 °C and 45 °C, or any humidity test from 10 °C to 20 °C. Tell us your test temperature when you order and we tune the system before shipping.

Do I need a water connection?

No. Steam comes from purified water in a 20 L tank behind the rear cover. Water the cooling coil pulls out of the air drips back into the tank by gravity, so most of it is used again.

steamhumid airdrips backby gravityfeedWorkspacesteam humidifies the airHumidifierboils water to steamCooling coilcondenses water outWater tank, 20 LRO or DI water, fill ½–¾Overflow outlet: surplus only, to a traysteamhumid airdrips backby gravityfeedWorkspacesteam humidifies the airHumidifierboils water to steamCooling coilcondenses water outWater tank, 20 LRO or DI water, fill ½–¾Overflow outlet: surplus only, to a tray
Tank
20 L, built in
One fill
up to about 7 days in normal use
Water
RO or DI only, ≤ 5 µS/cm; never tap water
Reuse
over 80% higher water utilization*

*Manufacturer figure, compared with a chamber that drains its condensate. Long high-humidity tests use more water. Automatic top-up from a purified-water supply is available on request. Monthly: change the water and clean the tank.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the chamber inside is not included. Your confirmed ship date is included in the order acknowledgement.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded. A 2-year extended warranty is available.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose size, voltage and options

The price, delivery date and PDF quote update with your choices.

Configure yours