Lab Shaker

LORDERAN Benchtop Open Air Orbital Shaker, Single-Shaft Balance Drive Laboratory Shaker, Quiet & Stable Continuous Run

SKU
300D
Availability
In stock
Questions

Ask about this instrument

LORDERAN Benchtop Open Air Orbital Shaker, Single-Shaft Balance Drive Laboratory Shaker, Quiet & Stable Continuous Run

An engineer replies by email or phone, usually within 12 hours.

Model · 300D
Power · 220V

A benchtop open-air orbital shaker for flasks and bottles in a temperature-controlled room or warm room. A single-shaft balanced drive stays quiet and stable through continuous runs at 30 to 300 rpm, with a 50 mm orbit on the 300D or 25 mm on the 310A, eight-segment programmes and soft start. It has no heating or cooling of its own.

LORDERAN200 rpm30–300 rpmBalanced driveSoft start
30–300 rpmspeed, ±1 rpm
25 · 50 mmorbit, 310A · 300D
Up to 35× 250 ml flasks
5000 mllargest flask, 310A
0–999 htimer or continuous
Cell cultureMicrobiologySolubility testingExtractionTeaching labs

300D or 310A?

300D: a 680 × 500 mm plate and a 50 mm orbit. 310A: lighter, a 550 × 400 mm plate and a 25 mm orbit, for flasks up to 5000 ml.

Where can it run?

It is open-air with natural convection, so it runs in a temperature-controlled room or warm room.

What happens after a power cut?

The run resumes with the previous settings when power returns.

Which power does it need?

AC 220 V, 50/60 Hz as standard, with 110 V, 60 Hz optional.

300D / 310A Benchtop Orbital Shaker datasheet (5 pages)

Full specifications, capacity planning, motion and temperature performance, installation requirements and warranty in one document to share with your team.
Download datasheet

A steady orbit, every revolution

The single-shaft balanced drive turns the plate on a precise circle with low noise and vibration. Choose 50 mm for vigorous mixing on the 300D or 25 mm for gentler motion on the 310A.

Ø 25 / 50 mm orbit30–300 rpm±1 rpm accuracySoft startEvery flask traces the same circle
  • LCD backlit display.
  • Parameter encryption and lock.
  • Running parameter memory.
  • Over-speed sound and light alarm.
±1 rpmrotary accuracy
680 × 500mm plate, 300D
550 × 400mm plate, 310A
8programme segments

Speed and orbit set the mixing

How hard the platform pushes your flasks depends on speed and orbit: the peak acceleration grows with the square of the speed and in proportion to the orbit. At 300 rpm a 25 mm orbit reaches about 1.26 g. A 50 mm orbit gives 2 times the acceleration of a 25 mm one at the same speed, so it mixes and aerates larger flasks without running faster.

25 mm orbit310A50 mm orbit300D0 g0.5 g1 g1.5 g2 g2.5 g3 g0100200300speed, rpm1.26 g2.52 g25 mm orbit310A50 mm orbit300D0 g0.5 g1 g1.5 g2 g2.5 g3 g0100200300speed, rpm1.26 g2.52 g25 mm orbit · 310Aup to 300 rpm: 1.26 g peak50 mm orbit · 300Dup to 300 rpm: 2.52 g peak

Peak acceleration = (2π × rpm / 60)² × orbit radius, in multiples of g (9.81 m/s²). The drawing shows the orbits to scale.

Specifications

Models 300D and 310A. 220 V, with 110 V optional.

Differs between models

Model 300D 310 A
Control
Control Mode PID (Microcomputer scans the micro-processing chip)
Display Mode LCD display
Program Control Eight segments of user-programmed programs
Safety Function Automatic run, automatic stop, timing run, clock display, calls recovery, parameters memory
Additional Function Watchdog timer, independent excess speed sound/light alarm, independent electric leakage, leakage/surge protection device
Shaking
Circulation Mode Natural convection type
Shaking Mode Orbital
Drive Mode Balancing device with single shaft
Speed Range 30 to 300 rpm 30-300 rpm
Rotary Accuracy ±1 rpm
Orbit Dia. 50 mm Dia. 25 mm
Timing Range 0 – 999h59mins/continuous
Size of Shaking Plate 680 × 500 mm 550 × 400 mm
Flask Clamp 250 ml*35 or 500 ml*24 or 1000 ml*15 or 2000 ml*9 250 ml*25 or 500 ml*15 or 1000 ml*6 or 2000 ml*5 or 5000 ml*3
Size, weight and power
Environmental Requirements User-specific thermostatic indoor or environment
External size 680x615x240 mm 550x480x220 mm
Net Weight 108 kg 50 kg
Power Supply AC220 V±10%; 50/60 Hz; 110 V±10%, 60 Hz (Optinoal)

How many flasks?

Clamp configurations, one flask size per load.

Flask
300D
310 A
250 ml
35
25
500 ml
24
15
1000 ml
15
6
2000 ml
9
5
5000 ml
–
3
Plate
680 × 500 mm
550 × 400 mm
Orbit
Ø 50 mm
Ø 25 mm

Quiet, stable and safe

Made for long, unattended runs on the bench.

Single-shaft balanced drive

Low noise and vibration for quiet, continuous runs.

Soft start

Gradual acceleration protects your samples from splashing.

Over-speed alarm

Independent sound and light alarm.

Parameter encryption

Lock settings to prevent mistakes.

Power-failure recovery

Resumes the previous settings when power returns.

Inverter motor

Maintenance-free and energy-saving.

Cast and ductile iron

Heavy key components for stability.

Leakage and surge protection

Independent electrical protection with a watchdog timer.

More LORDERAN shakers

Open-air shakers for any room, and incubator shakers when you need temperature control.

Questions buyers ask

Warranty, returns, delivery and quotes.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, belts and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the shaker inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose model and voltage

The price and PDF quote update with your choices.

Configure yours