Fume Hood

LORDERAN Ducted Fume Hood A Series, Weak Acid and Alkali Resistant Laboratory Hood with Motorized Sash, Phenolic Resin Worktop, Optional Carbon Filter

SKU
FH1000A-110
Availability
In stock
Brand
LORDERAN
Type · FH1000A
Power · 110V

A ducted fume hood with a motorized front window, a built-in centrifugal blower and a chemical-resistant phenolic resin worktop. Fumes are drawn away from you at 0.3 to 0.8 m/s and sent outside through a Φ300 mm duct. Four widths from 3.28 to 5.9 ft, resistant to weak acids and alkalis, with a 3-year warranty.

DuctedMotorized window9-speed blowerPhenolic resin top3-year warranty
LORDERAN0.5 m/sMotorized sashΦ300 duct9 speeds
0.3–0.8m/s air velocity
590–1170m³/h exhaust
9 levelsblower speed
<68 dBnoise
3.28–5.9 ftfour widths
Chemistry labsSample digestionSolvent handlingTeaching labsQC labs
3-year warrantyMajor defects: full refund or replacement.
Free shipping, DDPDuties paid, no surprise import charges.
30-day money backReturn most new, unopened items.
110 V or 220 VChoose the supply that matches your lab.
CATALOG · PDFFume Hood A Series CatalogAll four widths, specifications and accessories in one document to share with your team.Download catalog

Fumes go up and out, never toward you

The blower draws room air in across the whole opening and up behind the rear baffle. Fumes are carried into the duct and outside the building, and the work area stays at negative pressure, so vapour cannot spill back into the room.

  • Negative pressure keeps vapour inside the hood.
  • Blower speed adjusts in 9 levels to suit the work.
  • Lower the sash to raise the face velocity at the opening.
  • The phenolic resin worktop resists the chemicals it handles.
590–1170m³/hexhaust volume
Φ300 mmPVC exhaust duct
9 levelsblower speed
520 mmmaximum opening

Specifications

Models FH1000A, FH1200A, FH1500A and FH1800A, each available in 110 V and 220 V versions.

Download the full catalog (PDF)

Differs between models

Model FH1000A FH1200A FH1500A FH1800A
Dimensions
External Size (mm) (w*d*h) 1040*800*2200 1240*800*2200 1540*800*2200 1840*800*2200
Internal Size (mm) (w*d*h) 820*670*730 1020*670*730 1320*670*730 1620*670*730
Work Surface Height 850 mm
Max Opening 520 mm
Gross Weight 286kg 317kg 350kg 400kg
Main Packing Size 1190*990*1690 1390*990*1690 1690*990*1690 1990*990*1690
Base Packing Size 1190*990*900 1390*990*900 1690*990*900 1990*990*900
Airflow
Air Velocity 0.3~0.8m/s
Exhaust Volume 590m³/h 730m³/h 950m³/h 1170m³/h
Exhaust Duct PVC, Φ300mm
Blower Yes
Cabinet and electrical
LED Lamp 8W*1 12W*1 16W*1 16W*1
UV Lamp Yes
Front Window Motorized
Consumption 400W 400W 500W 500W
Optional Accessory Active carbon filter

Choose a size

Every width shares the same controls, materials and air velocity. Front elevations drawn to the same scale.

FH1000A1040 mm820 mm insideFH1200A1240 mm1020 mm insideFH1500A1540 mm1320 mm insideFH1800A1840 mm1620 mm inside

Why labs choose it

Built to handle chemicals safely, day after day.

Motorized front window

Height-adjustable at the touch of a button.

9-level air speed

A built-in centrifugal fan with extremely low noise and vibration.

Microprocessor panel

Easy-to-use controls with alarms for unsafe conditions.

UV light

UV emission at 253.7 nm for decontamination.

Phenolic resin worktop

Chemical-resistant and easy to wipe clean.

Power-off memory

Settings are kept through a power cut.

Optional carbon filter

Add an active carbon filter when you need one.

Easy to install

Assemble the base, fix the main body and connect the duct.

Compare the LORDERAN fume hood range

Five series, one standard of safety. Pick the body, window and exhaust that suit your chemistry.

Series
A SeriesThis product
Body
Cold-rolled steel
Cold-rolled steel
PP, porcelain white
Cold-rolled steel
Cold-rolled steel
Front window
Motorized
Manual
Manual
Motorized
Manual, acrylic
Exhaust
Duct, Φ300 mm
Duct, Φ300 mm
Duct, Φ250 mm
Duct, Φ300 mm
No duct, chemical filter
Resistance
Weak acids, alkalis
Weak acids, alkalis
Strong acids, alkalis
Weak acids, alkalis
Weak acids, alkalis
Filter
Carbon, optional
Optional
Carbon, optional
Carbon included
Chemical, included
Widths
1040–1840 mm
1000–1800 mm
1047–1847 mm
1000–1800 mm
1000–1800 mm

Questions buyers ask

Straight answers before you order.

Do I need a duct?

Yes. This is a ducted hood: fumes leave the building through a PVC exhaust duct, Φ300 mm. If you cannot run a duct, look at the LORDERAN ductless fume hood.

Which series should I choose for strong acids?

The P Series. Its PP body, phenolic resin worktop and acid-resistant glass are rated for strong acids and alkalis. The A, E, X and ductless hoods are rated for weak acids and alkalis.

How hard is installation?

Assemble the base cabinet, fix the main body on top, then connect the exhaust duct.

Which voltage should I order?

Every model is offered in 110 V and 220 V versions.

What does the warranty cover?

A 3-year warranty. Major defects under warranty are covered by a full refund or replacement.

Download documents

Catalog, user manual and service manual as PDF files.

Free shipping

Free shipping on all orders, with some international restrictions.

3-year warranty

3-year warranty. Major defects under warranty are covered by a full refund or replacement.

30-day money back

Return most new, unopened items within 30 days.

DDP shipping

Delivered duty paid, so there are no surprise import charges on arrival.