Fume Hood

LORDERAN Ducted Fume Hood P Series, Strong Acid and Alkali Resistant Laboratory Fume Hood with Blower, Phenolic Resin Bench, Manual Front Window

SKU
FH1000P-110
Availability
In stock
Brand
LORDERAN
Type · FH1000P
Power · 110V

A fume hood built for strong acids and alkalis. The body is porcelain-white PP, the worktop is phenolic resin, and the 5 mm toughened glass window resists acid and alkali too. A PP centrifugal blower with 9 speeds sends fumes out through a Φ250 mm duct. Four widths, 3-year warranty.

Strong acid resistantPP bodyManual window9-speed blower3-year warranty
LORDERAN0.5 m/sStrong acidsPP bodyΦ250 duct
Strongacid and alkali resistance
0.3–0.8m/s air velocity
560–1130m³/h exhaust
740 mmmaximum opening
1047–1847mm, four widths
Chemistry labsSample digestionSolvent handlingTeaching labsQC labs
3-year warrantyMajor defects: full refund or replacement.
Free shipping, DDPDuties paid, no surprise import charges.
30-day money backReturn most new, unopened items.
110 V or 220 VChoose the supply that matches your lab.
CATALOG · PDFFume Hood P Series CatalogAll four widths, specifications and accessories in one document to share with your team.Download catalog

Fumes go up and out, never toward you

The blower draws room air in across the whole opening and up behind the rear baffle. Fumes are carried into the duct and outside the building, and the work area stays at negative pressure, so vapour cannot spill back into the room.

  • Negative pressure keeps vapour inside the hood.
  • Blower speed adjusts in 9 levels to suit the work.
  • Lower the sash to raise the face velocity at the opening.
  • The phenolic resin worktop resists the chemicals it handles.
560–1130m³/hexhaust volume
Φ250 mmPVC exhaust duct
9 levelsblower speed
740 mmmaximum opening

Specifications

Models FH1000P, FH1200P, FH1500P and FH1800P, each available in 110 V and 220 V versions.

Download the full catalog (PDF)

Differs between models

Model FH1000P FH1200P FH1500P FH1800P
Dimensions
External Size (mm) (w*d*h) 1047*800*2450 1247*800*2450 1547*800*2450 1847*800*2450
Internal Size (mm) (w*d*h) 787*560*700 987*560*700 1287*560*700 1587*560*700
Work Surface Height 820 mm
Max Opening 740 mm
Gross Weight 226kg 254kg 294kg 346kg
Main Packing Size 1188*938*1612 1388*938*1612 1688*938*1612 1988*938*1612
Base Packing Size 1188*888*1000 1388*888*1000 1688*888*1000 1988*888*1000
Airflow
Air Velocity 0.3~0.8m/s
Exhaust Volume 560m³/h 700m³/h 920m³/h 1130m³/h
Exhaust Duct PVC, Φ250mm
Blower 1 1 1 2
Cabinet and electrical
LED Lamp 24W*1 24W*1 30W*1 38W*1
Front Window Manual
Consumption 400W 400W 500W 700W
Optional Accessory Active carbon filter

Choose a size

Every width shares the same controls, materials and air velocity. Front elevations drawn to the same scale.

FH1000P1047 mm787 mm insideFH1200P1247 mm987 mm insideFH1500P1547 mm1287 mm insideFH1800P1847 mm1587 mm inside

Why labs choose it

Built to handle chemicals safely, day after day.

Strong acid resistance

PP body, phenolic resin worktop and acid-resistant glass for aggressive chemistry.

Manual front window

5 mm toughened glass, height adjustable.

9-level air speed

A PP centrifugal blower; the 1800 model has two.

Microprocessor panel

Alarms for unsafe conditions, low noise and vibration.

PP water tap and sink

With a PP gas tap, supplied as standard.

Power-off memory

Settings are kept through a power cut.

Optional carbon filter

Add an active carbon filter when required.

Easy to install

Assemble the base and fix the main body.

What's in the box

Standard accessories, so installation is just a matter of connecting services.

2 waterproof socketsPP water tapPP gas tapWater sinkPP centrifugal blowerPipe straps ×2 (×4 for FH1800P)

Compare the LORDERAN fume hood range

Five series, one standard of safety. Pick the body, window and exhaust that suit your chemistry.

Series
P SeriesThis product
Body
Cold-rolled steel
Cold-rolled steel
PP, porcelain white
Cold-rolled steel
Cold-rolled steel
Front window
Motorized
Manual
Manual
Motorized
Manual, acrylic
Exhaust
Duct, Φ300 mm
Duct, Φ300 mm
Duct, Φ250 mm
Duct, Φ300 mm
No duct, chemical filter
Resistance
Weak acids, alkalis
Weak acids, alkalis
Strong acids, alkalis
Weak acids, alkalis
Weak acids, alkalis
Filter
Carbon, optional
Optional
Carbon, optional
Carbon included
Chemical, included
Widths
1040–1840 mm
1000–1800 mm
1047–1847 mm
1000–1800 mm
1000–1800 mm

Questions buyers ask

Straight answers before you order.

Do I need a duct?

Yes. This is a ducted hood: fumes leave the building through a PVC exhaust duct, Φ250 mm. If you cannot run a duct, look at the LORDERAN ductless fume hood.

Which series should I choose for strong acids?

The P Series. Its PP body, phenolic resin worktop and acid-resistant glass are rated for strong acids and alkalis. The A, E, X and ductless hoods are rated for weak acids and alkalis.

How hard is installation?

Assemble the base cabinet, fix the main body on top, then connect the exhaust duct.

Which voltage should I order?

Every model is offered in 110 V and 220 V versions.

What does the warranty cover?

A 3-year warranty. Major defects under warranty are covered by a full refund or replacement.

Download documents

Catalog, user manual and service manual as PDF files.

Free shipping

Free shipping on all orders, with some international restrictions.

3-year warranty

3-year warranty. Major defects under warranty are covered by a full refund or replacement.

30-day money back

Return most new, unopened items within 30 days.

DDP shipping

Delivered duty paid, so there are no surprise import charges on arrival.