LORDERAN Tablet Four-Usage Tester, 4-in-1 Tablet Hardness Disintegration Friability Dissolution Tester, Professional Pharmaceutical Lab Equipment
- SKU
- PJ-4D
- Availability
- In stock
- Questions
Hardness, friability, disintegration and dissolution testing in one instrument, for small QC and teaching labs. The PJ-4D runs three dissolution stations and one friability drum, the PJ-6D six stations and two drums; dissolution and disintegration share one temperature-controlled bath.
Which tests can it run?
Hardness to 199.9 N (499.9 N with the 50 kg option), friability, disintegration in two nacelles, and dissolution.
PJ-4D or PJ-6D?
3 dissolution stations and 1 drum, or 6 stations and 2 drums. 580 × 380 or 580 × 520 mm.
How stable is the bath?
20 to 40 °C within ±0.3 °C, shared by dissolution and disintegration.
Which power does it need?
220 V / 50 Hz or 110 V / 60 Hz.
PJ-4D / PJ-6D 4-in-1 Tablet Tester datasheet (6 pages)
Full specifications, USP <701>, <711> and <1216> reference tables, installation and warranty in one document to share with your team.Download datasheetFour tests, one footprint
Everything a small QC lab or teaching lab needs for solid dosage forms, sharing one controller and one water bath.
How friability is judged
The tablets are weighed, tumbled and weighed again; friability is the weight lost, as a percentage of the starting weight. USP <1216> uses whole tablets close to 6.5 g (10 tablets if each weighs more than 650 mg), 100 rotations at 25 ± 1 rpm, and a mean loss of not more than 1.0 % is acceptable for most products.
Example weights for illustration. Your monograph or protocol sets the sample, the rotation count and the limit.
How results are accepted
Results are judged against Q, the amount of active ingredient the monograph requires in solution by the stated time. For immediate-release forms USP <711> accepts in up to three stages, and each stage adds more vessels, so a six-station bath runs Stage 1 in a single pass.
Summary of the USP <711> acceptance table for immediate-release dosage forms. Your monograph defines Q and the time point.
Specifications
Models PJ-4D and PJ-6D. 220 V / 50 Hz or 110 V / 60 Hz.
Differs between models
| Model | PJ-4D | PJ-6D |
|---|---|---|
| General | ||
| Testing Parameter | Hardness, Friability, Disintegration, Dissolution | |
| Temperature Range | 20 to 40 °C, ±0.3 °C | |
| Speed Range | 20 to 200 rpm ±2 rpm | |
| Timing Range | 1 to 900 min ±0.5 min | |
| Dissolution | ||
| Paddle Radial Run-Out | ±0.5 mm | |
| Basket Radial Run-Out | ±1.0 mm | |
| Centering | ±2.0 mm | |
| Dissolution | 3 | 6 |
| Disintegration | ||
| Nacelles | 2 | |
| Nacelle Glass Tubes | 6 | |
| Volume Of The Beaker | 1000 ml | |
| Nacelle Up And Down Frequency | 30 to 32/min | |
| Nacelle Up And Down Range | 55 ± 1 mm | 55 ± 2 mm |
| Friability | ||
| Drum | 1 | 2 |
| Drum's Radius | Dia. 286 mm | |
| Drum's Depth | 39 mm | |
| Tablet Falling Height | 156 mm | |
| Rotation Count | 100 r | |
| Rotation Speed | 25 rpm | |
| Speed Regulator Accuracy | ±1 rpm | |
| Hardness | ||
| Hardness Range | 2 to 199.9N (50Kg, 499.9N is optional) | |
| Probe Procession Range | 3 to 40 mm | |
| Instrument | ||
| Power Supply | 220 V/ 50 Hz, 110 V/ 60 Hz | |
| Power | 500 W | 600 W |
| Dimension | 580×380×470 mm | 580×520×470 mm |
| Weight | 31 Kg | 42 Kg |
Smart, automatic, space-saving
One instrument replaces four on the bench.
LCD, preset and live
Preset parameters; preset and real-time values alternate on screen.
Uniform bath
Magnetic-drive water pump circulation, 20–40 °C, ±0.3 °C.
Automatic hardness press
Digital readout from a high-precision pressure sensor.
Timed shutdown
Automatic control, diagnosis, alarm and cyclic testing.
SUS316L
Imported stainless steel baskets and paddle rods.
One footprint
580 mm wide; 31 kg (PJ-4D) or 42 kg (PJ-6D).
Explore the LORDERAN tablet testing range
Hardness, friability, disintegration and dissolution, as single instruments or combined.
Questions buyers ask
Methods, warranty, returns, delivery and quotes.
Can tests run at the same time?
All four test systems share one instrument and one controller; dissolution and disintegration share the temperature-controlled bath.
What does the warranty cover?
A 1-year warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Glassware, seals and other wear parts are excluded.
Can I return it?
Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.
How is it delivered, and when does it ship?
Freight, duties and taxes are paid to your loading dock; moving the tester inside is not included. Your confirmed ship date is included in the order acknowledgement.
Can I get a formal quote for a purchase order?
Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.
Choose your model
The price and PDF quote update with your choice.