LORDERAN Benchtop Open Air Orbital Shaker, Single-Shaft Balance Drive Laboratory Shaker, Quiet & Stable Continuous Run
- SKU
- 300D
- Availability
- In stock
- Questions
A benchtop open-air orbital shaker for flasks and bottles in a temperature-controlled room or warm room. A single-shaft balanced drive stays quiet and stable through continuous runs at 30 to 300 rpm, with a 50 mm orbit on the 300D or 25 mm on the 310A, eight-segment programmes and soft start. It has no heating or cooling of its own.
300D or 310A?
300D: a 680 × 500 mm plate and a 50 mm orbit. 310A: lighter, a 550 × 400 mm plate and a 25 mm orbit, for flasks up to 5000 ml.
Where can it run?
It is open-air with natural convection, so it runs in a temperature-controlled room or warm room.
What happens after a power cut?
The run resumes with the previous settings when power returns.
Which power does it need?
AC 220 V, 50/60 Hz as standard, with 110 V, 60 Hz optional.
300D / 310A Benchtop Orbital Shaker datasheet (5 pages)
Full specifications, capacity planning, motion and temperature performance, installation requirements and warranty in one document to share with your team.Download datasheetA steady orbit, every revolution
The single-shaft balanced drive turns the plate on a precise circle with low noise and vibration. Choose 50 mm for vigorous mixing on the 300D or 25 mm for gentler motion on the 310A.
- LCD backlit display.
- Parameter encryption and lock.
- Running parameter memory.
- Over-speed sound and light alarm.
Speed and orbit set the mixing
How hard the platform pushes your flasks depends on speed and orbit: the peak acceleration grows with the square of the speed and in proportion to the orbit. At 300 rpm a 25 mm orbit reaches about 1.26 g. A 50 mm orbit gives 2 times the acceleration of a 25 mm one at the same speed, so it mixes and aerates larger flasks without running faster.
Peak acceleration = (2π × rpm / 60)² × orbit radius, in multiples of g (9.81 m/s²). The drawing shows the orbits to scale.
Specifications
Models 300D and 310A. 220 V, with 110 V optional.
Differs between models
| Model | 300D | 310 A |
|---|---|---|
| Control | ||
| Control Mode | PID (Microcomputer scans the micro-processing chip) | |
| Display Mode | LCD display | |
| Program Control | Eight segments of user-programmed programs | |
| Safety Function | Automatic run, automatic stop, timing run, clock display, calls recovery, parameters memory | |
| Additional Function | Watchdog timer, independent excess speed sound/light alarm, independent electric leakage, leakage/surge protection device | |
| Shaking | ||
| Circulation Mode | Natural convection type | |
| Shaking Mode | Orbital | |
| Drive Mode | Balancing device with single shaft | |
| Speed Range | 30 to 300 rpm | 30-300 rpm |
| Rotary Accuracy | ±1 rpm | |
| Orbit | Dia. 50 mm | Dia. 25 mm |
| Timing Range | 0 – 999h59mins/continuous | |
| Size of Shaking Plate | 680 × 500 mm | 550 × 400 mm |
| Flask Clamp | 250 ml*35 or 500 ml*24 or 1000 ml*15 or 2000 ml*9 | 250 ml*25 or 500 ml*15 or 1000 ml*6 or 2000 ml*5 or 5000 ml*3 |
| Size, weight and power | ||
| Environmental Requirements | User-specific thermostatic indoor or environment | |
| External size | 680x615x240 mm | 550x480x220 mm |
| Net Weight | 108 kg | 50 kg |
| Power Supply | AC220 V±10%; 50/60 Hz; 110 V±10%, 60 Hz (Optinoal) | |
How many flasks?
Clamp configurations, one flask size per load.
Quiet, stable and safe
Made for long, unattended runs on the bench.
Single-shaft balanced drive
Low noise and vibration for quiet, continuous runs.
Soft start
Gradual acceleration protects your samples from splashing.
Over-speed alarm
Independent sound and light alarm.
Parameter encryption
Lock settings to prevent mistakes.
Power-failure recovery
Resumes the previous settings when power returns.
Inverter motor
Maintenance-free and energy-saving.
Cast and ductile iron
Heavy key components for stability.
Leakage and surge protection
Independent electrical protection with a watchdog timer.
More LORDERAN shakers
Open-air shakers for any room, and incubator shakers when you need temperature control.
Questions buyers ask
Warranty, returns, delivery and quotes.
What does the warranty cover?
A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, belts and other wear parts are excluded.
Can I return it?
Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.
How is it delivered, and when does it ship?
Freight, duties and taxes are paid to your loading dock; moving the shaker inside is not included. Your confirmed ship date is included in the order acknowledgement.
Can I get a formal quote for a purchase order?
Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.
Choose model and voltage
The price and PDF quote update with your choices.