LORDERAN Damp Heat Test Chamber with Water Recirculation for 85/85 & 95/95 Testing, 60–100°C, 80–98%RH, 316 Stainless Steel Interior

SKU: HWS150H
Availability: In Stock
$9,357.00 SGD
$9,357.00 SGD
Capacity: 150L
Power: 110V
Subtotal: $9,357.00

Free Shipping

Free shipping on all orders.

Non-Repairable Warranty Policy

Major defects (Non-repairable) under warranty, a full refund or a replacement unit.

30 Day Money Back Guarantee

If approved, you’ll be automatically refunded on your original payment method.

DDP Shipping Terms

Lorderan paying for all charges including freight, duties, taxes, customs clearance charges up to the customer's door, warehouse or fulfillment center.
LORDERAN Damp Heat Test Chamber with Water Recirculation for 85/85 & 95/95 Testing, 60–100°C, 80–98%RH, 316 Stainless Steel Interior

LORDERAN Damp Heat Test Chamber with Water Recirculation for 85/85 & 95/95 Testing, 60–100°C, 80–98%RH, 316 Stainless Steel Interior

$9,357.00

LORDERAN Damp Heat Test Chamber with Water Recirculation for 85/85 & 95/95 Testing, 60–100°C, 80–98%RH, 316 Stainless Steel Interior

$9,357.00
Capacity: 150L
Power: 110V

A high temperature, high humidity test chamber built for one job and built to do it for weeks: damp-heat endurance testing. It holds 60 to 100 °C at 80 to 98 %RH, the region where Double 85 (85 °C / 85 %RH) and Double 95 (95 °C / 95 %RH) testing live. A SUS316 stainless steel interior, forced-air circulation and Pt100 sensors keep conditions steady hour after hour. Four sizes from 150 to 1000 L.

Double 85 and 95Long-duration damp heatSUS316 interiorTouch-screen controlPt100 sensors
LORDERAN85 °C85 %RHSUS316 interior85 °C80–98 %RHDouble 85 · 95
60–100 °Ctemperature range
80–98 %RHhumidity range
±0.5 °Ctemperature fluctuation
SUS316stainless interior
150–1000 Lfour sizes
Electronic componentsPhotovoltaic modulesBatteriesPolymers and plasticsAerospace and instruments
2-year warrantyMajor defects: full refund or replacement.
Free shipping, DDPDuties paid, no surprise import charges.
30-day money backReturn most new, unopened items.
220 V or 110 VChoose the supply that matches your lab.

Made for Double 85 and Double 95

Double 85 and Double 95 are the reliability and accelerated-ageing tests the electronics, photovoltaic and automotive parts industries rely on. Heat speeds up chemistry; humidity drives moisture into seals, laminates and packages. Together they reveal in weeks the corrosion, delamination and insulation failures that would take years in the field. This chamber is dedicated to that window, held without a break.

5060708090100110707580859095100Temperature (°C)Relative humidity (%RH)60 °C · 98 %100 °C · 98 %60 °C · 80 %100 °C · 80 %Double 8585 °C · 85 %RHDouble 9595 °C · 95 %RHWORKING ENVELOPE1000 habout six weeks,non-stopA typical damp-heat endurance test
5060708090100110707580859095100Temperature (°C)Relative humidity (%RH)60 °C · 98 %100 °C · 98 %60 °C · 80 %100 °C · 80 %Double 8585 °C · 85 %RHDouble 9595 °C · 95 %RHWORKING ENVELOPE1000 habout six weeks,non-stopA typical damp-heat endurance test
85/85 · 95/95°C / %RH, both inside the envelope
≤ ±3 %RHhumidity deviation
≤ 2 °Ctemperature uniformity
0.01 °Csetting resolution

Specifications

Models HWS-150H, HWS-250H, HWS-500H and HWS-1000H. 220 V or 110 V.

Differs between models

Model HWS-150H HWS-250H HWS-500H HWS-1000H
Model and dimensions
Volume 150L 250L 500L 1000L
Interior size (W*D*H) 600*405*620mm 600*500*830mm 800*700*900mm 1000*1000*1000mm
External size (W*D*H) 870*810*1500mm 870*900*1720mm 1060*1120*1730mm 1250*1410*1820mm
Structure Integrated, one-piece
Performance
Temperature range 60℃~+100℃
Temperature fluctuation ≤±0.5℃
Temperature deviation ≤±2℃
Temperature uniformity ≤2℃
Heating rate 3℃≤1min
Humidity range 80%RH~98%RH
Humidity deviation ≤±3%RH
Control method Forced air circulation, balanced temperature and humidity control
Chamber construction
Exterior High-quality cold-rolled steel, powder coated
Interior High-quality SUS316 stainless steel
Insulation Rigid polyurethane foam
Door Hinged single door; door frame with anti-condensation heater
Shelves 3 layers; stainless steel grid racks welded from round bars, >30 kg each, adjustable spacing
Water ports One inlet and one outlet, Φ8mm
Air conditioning system
Air circulation Centrifugal fan
Heating Nickel-chromium wire heater, PID control, solid-state relay
Humidification Circulating water-evaporation humidifier with water recirculation system
Temperature sensor Armored platinum resistance, Pt100 class 0.05
Humidity sensor Armored platinum resistance, Pt100 class 0.05
Controller
Controller Touch-screen temperature and humidity controller
Indication accuracy Temperature 0.1℃, humidity 0.1%RH
Setting and display resolution Temperature 0.01℃, humidity 0.1%RH, time 1min
Electrical
Maximum power 1.5KW 1.5KW 2.5KW 2.5KW
Power supply 220V or 110V
Air switch capacity 25A (220V)
Test standards
Designed and built to GB10586-8 and GB/T 2423.3-93, IEC 60068-2-78, IEC 60068-2-30, IEC 60068-3, JESD22-A101D / JESD22A-101, IEC 61215 / IEC 61730, MIL-STD-810 (relevant clauses)

Choose a size

Same envelope, controller and protection on every size. Front elevations drawn to the same scale.

HWS-150H830 mm600*405*620 insideHWS-250H820 mm600*500*830 insideHWS-500H1000 mm800*700*900 insideHWS-1000H1230 mm1000*1000*1000 inside

Even conditions on every shelf

A dedicated air duct sits at one end of the work space, holding the fan, heater and humidifier inlet. Air is drawn in low, conditioned, and blown out evenly across the samples, then drawn back again, in a continuous loop with no dead corners.

Air ductCentrifugal fanNi-Cr heaterHumidifier inletReturn air drawn in at the bottomEven, conditioned airflow across every shelfSUS316

Engineered for weeks of continuous damp heat

Every detail chosen for stability, corrosion resistance and unattended running.

SUS316 stainless interior

Molybdenum-bearing 316 stainless steel for a long life in hot, saturated air.

Anti-condensation door frame

A heated door frame keeps the seal dry and the door closing tight.

Pt100 class 0.05 sensors

Armored platinum resistance sensors for temperature and humidity.

Touch-screen controller

Set to 0.01 °C and 0.1 %RH, with full curve display and guided setup.

Self-calibration

Correct the temperature and humidity reference points from the controller.

Power-failure recovery

Resumes after a power cut, with run-wait, stop and maintenance modes.

Water recirculation

A circulating water-evaporation humidifier reuses its water, so refills are rare. Low-water protection and Φ8 mm ports.

Three adjustable shelves

Stainless steel grid racks, each carrying more than 30 kg.

Where long damp-heat testing matters

From chips to solar panels, products that live outdoors or near heat are proven here.

Semiconductors and componentsDouble 85 and steady-state temperature humidity life testing such as JESD22-A101.
Photovoltaic modulesDamp-heat qualification and safety testing to IEC 61215 and IEC 61730.
Batteries and power electronicsMoisture resistance of housings, seals and insulation.
Polymers and plasticsFading, shrinkage, loss of strength and ageing under heat and humidity.
Aerospace and instrumentsHumidity resistance to the relevant clauses of MIL-STD-810.
Automotive parts and building chemicalsDouble 85 and Double 95 ageing of parts, coatings, adhesives and materials.

Damp-heat specialist or all-round climate chamber?

Choose the dedicated chamber when your tests live at high heat and high humidity for a long time.

Chamber
High temp. high humidityThis product
Built for
Long, continuous damp-heat tests
General temperature and humidity testing
General testing down to −70 °C
Temperature
60 to 100 °C
−40 to 150 °C
−70 to 150 °C
Humidity
80 to 98 %RH
20 to 98 %RH
20 to 98 %RH
Interior
SUS316 stainless steel
SUS304 stainless steel
2 mm stainless steel
Sizes
150–1000 L
100–1000 L
100–1000 L

Safety, installation and delivery

Everything to plan before the chamber arrives.

Show all 7 safety protections
  • Chamber over-temperature alarm protection
  • Chamber over-humidity alarm protection
  • Structural safety grounding
  • Heater short-circuit protection
  • Humidifier low-water protection
  • Blower over-current protection
  • Phase sequence protector
Installation requirements
  • Power: 220 V or 110 V; air switch 25 A (220 V)
  • Level, well-ventilated floor rated for at least 800 kg/m²
  • A floor drain close to the chamber
  • No strong vibration, strong electromagnetic fields, flammable, explosive or corrosive substances, or dust nearby
  • Clearance: at least 1000 mm behind the chamber and 800 mm at the sides
  • Room conditions: 5 to 35 °C, ≤ 85 %RH, 86 to 106 kPa
Samples you should not test
  • Explosive or flammable substances, or samples containing them
  • Corrosive substances
  • Samples that exceed the permitted heat load
What you receive

The chamber is delivered with a user manual and a maintenance manual. It is assembled on site, commissioned and accepted at your facility.

Questions buyers ask

Straight answers before you order.

What is a Double 85 test?

A damp-heat test held at 85 °C and 85 %RH, commonly for 1000 hours, used for electronic components, photovoltaic modules and other products that must resist heat and moisture. It sits well inside this chamber’s 60–100 °C, 80–98 %RH envelope.

How is it different from a standard climate chamber?

It is dedicated to high heat and high humidity. Instead of covering low temperatures and low humidity, it focuses on holding 60 to 100 °C at 80 to 98 %RH steadily for very long tests, with a SUS316 interior for corrosion resistance.

Can it test below 60 °C or under 80 %RH?

No. For wider ranges, choose a LORDERAN climate chamber, which covers −40 or −70 °C to 150 °C and 20 to 98 %RH.

What is a Double 95 test?

A more severe damp-heat test held at 95 °C and 95 %RH. Like Double 85, it is a standard reliability and accelerated-ageing test in electronics, photovoltaics and automotive parts, and it is inside this chamber’s envelope.

How often do I need to add water?

Rarely. The circulating water-evaporation humidifier has a water recirculation system, with water-level control and low-water protection, and Φ8 mm inlet and outlet ports. Keep a floor drain nearby.

Which standards is it built to?

GB10586 and GB/T 2423.3, IEC 60068-2-78, IEC 60068-2-30, IEC 60068-3, JESD22-A101, IEC 61215 / IEC 61730 and the relevant clauses of MIL-STD-810.

Free shipping

Free shipping on all orders, with some international restrictions.

2-year warranty

2-year warranty. Major defects under warranty are covered by a full refund or replacement.

30-day money back

Return most new, unopened items within 30 days.

DDP shipping

Delivered duty paid, so there are no surprise import charges on arrival.

You May Also Like

Recently Viewed Products