LORDERAN Class II Type B2 Biological Safety Cabinet, 0% Recirculation 100% Exhaust ULPA Filtered Biosafety Hood with Touch Screen & Motorized Front Window, for Medical and Laboratory Use
- SKU
- 1100IIB2-PRO-2
- Availability
- In stock
- Brand
- LORDERAN
A Class II B2 total-exhaust biological safety cabinet. Nothing is recirculated: room air enters at 0.53 m/s, ULPA-filtered downflow protects the work at 0.33 m/s, and the exhaust leaves the lab through a dedicated duct. Widths from 3 ft to 5.2 ft, a 7-inch touch screen, a motorized front window and a 3-year warranty.
Total exhaust, zero recirculation
Every litre of air drawn into the cabinet is exhausted to the outside. That is why a B2 cabinet is the usual choice when biological work also involves volatile toxic chemicals or radionuclides.
- Inflow and downflow are monitored in real time by an airflow sensor.
- Alarms sound for abnormal airflow, filter change and an unsafe window height.
- Interlocks stop the UV lamp while the window is open or the LED lamp is on.
- Filter life is tracked by pressure sensors.
Specifications
Models 1100IIB2-PRO, 1500IIB2-PRO and 1800IIB2-PRO, each available in 110 V and 220 V versions.
Download the user manual (PDF)Differs between models
| Model | 1100IIB2-PRO | 1500IIB2-PRO | 1800IIB2-PRO |
|---|---|---|---|
| Dimensions | |||
| External Dims(W*D*H) | 1100*750*2255mm | 1500*770*2290mm | 1873*795*2280mm |
| Internal Dims(W*D*H) | 940*600*660mm | 1350*670*630mm | 1600*670*630mm |
| Tested Opening | Safety Height 200mm(8') | 200mm(8') | 200mm(8') |
| Max Opening | 420mm (17'') | 500mm (20'') | 500mm (20'') |
| Work Surface Height | 750mm | ||
| Gross Weight | 315kg | 381Kg | 460Kg |
| Package (Main Body) | 1250*990*1770mm | 1650*990*1820mm | 2000*1075*1910mm |
| Package (Exhaust Blower) | 930*800*690mm | 930*800*710mm | 920*710*680mm |
| Airflow and filtration | |||
| Inflow Velocity | 0.53±0.025 m/s | ||
| Down Flow Velocity | 0.33±0.025 m/s | ||
| CFM | 100%, 1050m3/h | 100%, 1270m3/h | 100%, 1800m3/h |
| Airflow System | 0% air recirculation, 100% air exhaust | ||
| Exhaust Duct | 4 meters PVC duct, Dia 300mm | ||
| ULPA Filter | Two, 99.9995% efficient at 0.12μm. Filter life indicator. | ULPA Filter | ULPA Filter |
| Cabinet and electrical | |||
| Front Window | Motorized, Anti UV | ||
| Noise | ≤67dB(A) | ||
| Consumption | 600W | 800W | 1300W |
| Socket | Two, total load: 500W | ||
| Standard Accessory | LED lamp*2, UV lamp*2, base stand, remote control, foot switch, exhaust blower, exhaust duct, drain valve, waterproof sockets*2, pipe strap*2 | ||
Choose a size
All widths share the same airflow, filters and controls. Front elevations drawn to the same scale.
Built for safe, comfortable daily work
The features you use every session, designed to keep the cabinet safe and simple to run.
100% total exhaust
No air is recirculated: everything drawn in leaves the cabinet through the exhaust system.
ULPA filtration
Two ULPA filters at 99.9995% for 0.12 μm particles: about 10 times the efficiency of HEPA, for an ISO Class 3 work zone.
7-inch touch screen
See inflow and downflow velocity, temperature and humidity, filter pressure, UV and filter run time, and filter life at a glance.
Motorized front window
Raise and lower the sash with one hand, and clean the upper glass easily.
Audible and visual alarms
Warnings for abnormal airflow, filter change and an unsafe front window height.
Safety interlocks
UV lamp with front window, UV lamp with LED lamp, and blower with front window.
Remote control
Run the main functions from up to 6 meters away.
Foot switch
Adjust the window height without lifting your hands from the work.
What's in the box
Delivered ready to work, with the accessories below as standard.
Which biosafety cabinet is right for you?
Every LORDERAN Class II cabinet protects the operator, the sample and the environment. Choose by airflow type, size and controller.
Questions buyers ask
Straight answers before you order.
Does the cabinet need a duct?
Yes. A B2 cabinet exhausts 100% of its air, so it connects to an exhaust duct to the outside. A 4 m PVC duct, Φ300 mm, is listed for every model; the exhaust blower is supplied as standard on the models that list it.
Why choose B2 over A2?
Because no air is recirculated, nothing that evaporates inside the cabinet is returned to the work zone or the room. That makes B2 the safer choice when volatile chemicals are part of the work.
Which voltage should I order?
Every model is offered in 110 V and 220 V versions. Choose the one that matches the sockets in your lab.
How do I know when the filter needs changing?
The controller tracks filter life and warns you with an audible and visual alarm when the filter needs to be changed.
What does the warranty cover?
The cabinet has a 3-year warranty. Major defects under warranty are covered by a full refund or replacement, and new, unopened items can be returned within 30 days.
Download documents
Catalogs and manuals as PDF files.
Free shipping
Free shipping on all orders, with some international restrictions.
3-year warranty
3-year warranty. Major defects under warranty are covered by a full refund or replacement.
30-day money back
Return most new, unopened items within 30 days.
DDP shipping
Delivered duty paid, so there are no surprise import charges on arrival.











