LORDERAN Wrist Action Lab Shaker - 0-600 RPM Variable Speed Benchtop Shaker with Adjustable 6/12/15° Angle & 12/16-Position Capacity

SKU
C810
Availability
In stock
Brand
Lorderan
Model · C810
LORDERAN · Wrist Action Lab Shaker

Wrist-like motion.
Precisely controlled.

Servo-driven wrist action with a 5-inch touch screen and programmable speed sequences. Choose 12 or 16 positions for controlled multi-vessel shaking.

Servo motor±1 rpm frequency accuracy12 or 16 positions
LORDERANWRIST ACTIONSPEEDTIME
0–600rpm frequency range
±1 rpmFrequency accuracy
5-inchColor touch screen
12 / 16Maximum vessel positions
A deliberate change of direction

Set the motion.
Define the method.

The arms oscillate back and forth to reproduce a wrist-like shaking action. Select the frequency and arm angle to suit your vessels, fill volume and procedure.

Servo drive and PID microprocessor control provide a specified frequency accuracy of ±1 rpm.

ALTERNATING ANGULAR MOTIONDirection changesTime

Motion illustration; animation speed and curve are not measured performance data.

Frequency

Set the oscillation frequency within the specified 0–600 rpm range.

Angle

10° nominal tilt, with 6°, 12° and 15° settings listed in the technical specifications.

Timing

Set time in seconds and start timing when the selected speed is reached.

Specifications

Models ZD-C810 and ZD-C820.Differs between models

Model ZD-C810 ZD-C820
Model and dimensions
Maximum positions 12 16
Main unit dimensions 272 × 452 × 300 mm 272 × 452 × 320 mm
Arm length, each side 348 mm 468 mm
Net weight 45 kg 46.5 kg
Motion and performance
Shaking motion Wrist action
Reciprocating frequency 0–600 rpm
Frequency accuracy ±1 rpm
Tilt angle 10° nominal; 6°, 12° and 15° settings listed
Oscillation radius 13.3 ±0.4 cm
Control and timing
Control system PID microprocessor control
Drive Servo motor
Display 5-inch color touch screen
Programming 30 stages; up to 100 cycles
Timer setting Second-level setting; timing can begin at the selected speed
Maximum timer range 0-9999h
Interface languages English
Memory functions Parameter memory and speed storage
Operating functions Automatic operation, automatic stop, timed operation, clock display and power-restoration recovery
Construction and protection
Mechanical chassis Single-cast ductile iron, precision machined
Housing / arms 304 stainless steel / aluminum
Bearings Imported double-row bearings
Monitoring Watchdog timer; independent audible and visual overspeed alarm
Electrical protection Independent leakage-current and electrical over-limit protection
Installation and configuration
Operating environment User-specified temperature-controlled room or suitable ambient environment
Circulation description Natural convection
Supply voltage 110V/220V
Vessel clamps / included items 12/16

Dimensions are reproduced in the order provided in the technical documents; axis orientation is not specified. Confirm the complete installed footprint, loading limits and final controller configuration before ordering.

Two capacities. One control platform.

12 or 16 positions.
Choose your capacity.

The same frequency range and control accuracy, with two vessel capacities. Select by position count, arm length and available bench space.

LORDERAN · ZD-C810

Compact arm configuration

12positions

For workflows that need up to 12 vessel positions with shorter arms.

Arm length, each side
348 mm
Main unit dimensions
272 × 452 × 300 mm
Net weight
45 kg
LORDERAN · ZD-C820

More vessel positions

16positions

For workflows that need up to 16 vessel positions and can accommodate longer arms.

Arm length, each side
468 mm
Main unit dimensions
272 × 452 × 320 mm
Net weight
46.5 kg

Position count is not a load rating. Usable capacity depends on vessel geometry, fill volume, clamp fit and the approved loading arrangement. Main-unit dimensions exclude the arms and vessel clearance.

Designed around the operator

Clear settings.
Practical control.

Direct access to the settings that matter: speed, time, program and operating status.

01

Settings in view

View set and actual speed and time, operating status and alarm records on the 5-inch touch screen.

02

Programmed sequences

Build sequences of up to 30 stages and repeat them for up to 100 cycles, as specified in the model parameter tables.

03

Servo-driven control

A servo motor regulates oscillation frequency. Parameter memory and speed storage support recurring procedures.

04

A stable mechanical core

A precision-machined, single-cast ductile iron chassis supports the drive assembly and twin shaking arms.

05

Practical construction

A 304 stainless steel housing and aluminum arms combine a laboratory-oriented exterior with accessible vessel mounting.

06

Clear daily operation

An English interface, a screen-lock key and a clock display keep routine settings and status accessible.

Overspeed alerts

Independent audible and visual overspeed alarms.

Electrical protection

Independent leakage-current and electrical over-limit protection devices.

Operating memory

Parameter retention and power-restoration recovery functions are listed for both models. Confirm restart behavior for your procedure.

Fit comes before vessel count

Your vessels.
The right configuration.

Suitable vessel types include Erlenmeyer flasks, reagent bottles, test tubes and separatory funnels. Compatibility depends on the selected clamps and loading arrangement.

01 · Vessel geometry

Provide vessel type, capacity, neck diameter and overall dimensions so the appropriate clamp arrangement can be confirmed.

02 · Working load

Specify fill volume, total loaded mass and the number of vessels. Confirm support and clearance for the chosen angle.

03 · Method settings

Share your target frequency, angle, timing and operating environment to check the configuration against your procedure.

Before you order

Practical answers for laboratory purchasing and method planning.

How do the two models differ?

ZD-C810 provides up to 12 positions, 348 mm arms on each side and a net weight of 45 kg. ZD-C820 provides up to 16 positions, 468 mm arms and a net weight of 46.5 kg. Main-unit dimensions also differ; confirm axis orientation with the final drawing.

Does it operate like an orbital shaker?

No. This instrument uses an alternating wrist-like action rather than a circular orbital path. Confirm that this motion matches your laboratory procedure.

Are vessels and clamps included?

The listed clamp configuration is 12 / 16. Confirm the clamp arrangement for your selected model, compatible vessel sizes and whether glassware is included.

Can it control sample temperature?

No active heating, cooling or temperature-control range is specified. The documents call for a user-selected temperature-controlled room or suitable ambient environment.

Can I use it for a pharmacopoeial test?

Confirm suitability against the exact method and current edition you use. Request the applicable configuration and supporting documentation; the listed motion settings are not a certification or a guarantee of method compliance.

What should I confirm about power and loading?

The listed supply options are 110 V / 220 V. Confirm your selected configuration, supply frequency, plug, rated power, maximum permissible load and installed clearance.

Free shipping

Free shipping on all orders, with some international restrictions.

3-year warranty

3-year warranty. Major defects under warranty are covered by a full refund or replacement.

30-day money back

Return most new, unopened items within 30 days.

DDP shipping

Delivered duty paid, so there are no surprise import charges on arrival.