200L Vertical Sterilizer Autoclave

1-year warranty. Come with single phase electric power. Automatic exhaust and cycle sterilization program. Fully stainless-steel structure. Arbitrary setting of temperature 50°C-134°C. Overpressure self-discharge 0.22mpa. With 2 stainless steel sterilizing baskets. Stop automatically after the buzzer reminder.
SKU: 200CA-DDP220
Availability: In Stock
$3,399.00
$3,999.00
$3,399.00
Power: 220V/28amps (NEMA 6-50P Plug)
Delivery Time: 30 Days
Subtotal: $3,399.00

Free Shipping

Free shipping from China on all orders (Door to Door)

30 Day Money Back Guarantee

If approved, you’ll be automatically refunded on your original payment method.

What DDP Term means

Lorderan paying for all charges including freight, duties, taxes, customs clearance charges up to the customer's door, warehouse or fulfillment center.
200L Vertical Sterilizer Autoclave

200L Vertical Sterilizer Autoclave

$3,999.00 $3,399.00

200L Vertical Sterilizer Autoclave

$3,999.00 $3,399.00
Power: 220V/28amps (NEMA 6-50P Plug)
Delivery Time: 30 Days

    Large Load, Powerful, Reliable

    Automatic high-pressure steam sterilization

    One-time molded stainless steel structure

    Plug & Play Installation

    Intelligent temperature control, fast heating

    High Sterilization Efficiency

    Easy To Replace Parts

    DESIGN

    OPERATE

    SAFETY

    01

    Small foot print

    LCD display

    Leakage breaker

    02

    Safety Interlocking

    up to 134℃

    Safety valve

    03

    Auto-exhaust 

    Easy setting

    Automatic shutdown

    04

    Full SS304

    Fully automatic

    Anti-dry burning

    05

    Large load

    Cycle Time Counter

    Overpressure protection

    Why we are better

    Lid

    Bolt type lid structure. Mechanical safety interlocking device.

    Display Panel

    Microprocessor control system, stable and easy to operate.

    Exhaust method

    Automatic exhaust, safe and worry-free.

    Sterilization

    Automatic cycle sterilization program.Takes 35-40 minutes for the ambient temperature to reach 132℃.

    Material

    All stainless-steel material.
    The inner liner is made of extra thick stainless steel, high safety coefficient.

    Plug

    Come standard with NEMA 10-50P plug. Removable and replaceable.

    Lid

    Bolt type lid structure. Mechanical safety interlocking device.

    Display Panel

    Microprocessor control system, stable and easy to operate.

    Exhaust method

    Automatic exhaust, safe and worry-free.

    Sterilization

    Automatic cycle sterilization program.Takes 35-40 minutes for the ambient temperature to reach 132℃.

    Material

    All stainless-steel material.
    The inner liner is made of extra thick stainless steel, high safety coefficient.

    Plug

    Come standard with NEMA 10-50P plug. Removable and replaceable.

    HOW TO USE
    • Open the lid, add enough water, the water level needs to be higher than the heating tube and the water level sensor (under the inner chamber).
    • at the same time, the water level light on the display panel is always on and not blinking (Tips: the water level should not exceed the tripod).
    • Each time we use the autoclave, make sure to replenish enough water intime,to avoid burning out the electric heating tube due to lack of water.
    1

    Step 01

    P-1: set it as 102°C-103°C. 

    When the heating temp. reach 102°C-103°C, the exhaust will close automaticlly. (Default is 102°C)

    2

    Step 02

    P-2: Set the sterilize temperature. Setting range is 105°C-134°C

    3

    Step 03

    P-3: Set the sterilize time, Timer range is 0-9999mins.

    4

    Step 04 (Optional)

    P-4: Set the drying time. (It's optional function, if it's not available in your autoclave, press the SET key to skip.)

    5

    Step 05

    P-5: It's sterilize mode. Press the SET key to skip, no need to change the mode.

    6

    Step 06

    P-6: Counting function. This displays the number of times the autoclave has been used.

    7

    Sterilize Mode*

    • Regarding the settings on the control panel: pcud, pcu5, pf1-l, pfr-5, pp1n, pb1n. this is the sterilization mode setting.

    • We don't need to change it, the default program is PFR-5, which is also the standard program of this sterilizer.

    • Don't worry if you change any of the parameters, this will not change the sterilization program in the autoclave.

    • We just need to turn off the power and reboot, the settings will be automatically reset to PFR-5.
    • If the system is not reset, we need to click on ADD KEY until the display shows PFR-5.
    8

    Exhaust valve*

    Automatic exhaust is standard.

    Do not operate the exhaust valve manually, keep the exhaust valve closed. (In case of emergency, open it manually for quick venting.)

    View, Download user manual

    This guide will help you get started with Lorderan 200L autoclave.

    You May Also Like

    Recently Viewed Products