Auto-Lifting Dissolution Tester (Manual Turned Over)

RC-3DT
$1,399.00
The head move up and down automatically, and the head could turned over manual.
The preset and real data could displayed alternately in time, also the timing function can be preset at many points.
IQ/OQ documents included free of charge.
It is manufactured in compliance to the USP and EP.
Model :
RC-3DT
RC-6DT
RC-8DT
$1,399.00
customers are viewing this product
For RC-3DT
  • It has 3 vessels and 3 poles arranged on one line.
  • The head move up/down automatically, also can be manual turned over smoothly and flexibly.
  • The basket units and paddle units are made of imported stainless steel (SUS316L).
  • The magnetism-pumped circular water current can heat the system evenly, and the bath liquid can achieve an equal temperature.
  • A MPU is used in dissolution tester to automatically control the temperature, rotational speed and time, and the parameters can be preset at any time.
  • It can be operated conveniently by keystroke. The measurement result is displayed and the preset and real data can be displayed alternately in time.
  • Automation: auto-test, auto-diagnose, auto-alarm.
For RC-6DT
  • It has 6 vessels and 6 poles arranged on one line.
  • The head move up/down automatically, also can be manual turned over.
  • The basket units and paddle units are made of imported stainless steel (SUS316L).
  • The magnetism-pumped circular water current can heat the system evenly, and the bath liquid can achieve an equal temperature.
  • A MPU is used in dissolution tester to automatically control the temperature, rotational speed and time, and the parameters can be preset at any time.
  • It can be operated conveniently by keystroke. The measurement result is displayed. The preset and real data can be displayed alternately in time.
  • Automation: auto-test, auto-diagnose, auto-alarm.
  • It can test by self and alarm automatically. The dissolution parameters of' Chinese codex 2020' are stored in and can be taken out at anytime.
  • Time can be preset at many points. The beeper sounds automatically to any point, and then the tester automatically runs to the next one.
 For RC-8DT
  • It has 8 vessels and 8 poles, with 4 vessels and 4 poles in front and other at back.
  • The head move up/down automatically, also can be manual turned over.
  • The basket units and paddle units are made of imported stainless steel (SUS316L).
  • The magnetism-pumped circular water current can heat the system evenly, and the bath liquid can achieve an equal temperature.
  • A MPU is used in dissolution tester to automatically control the temperature, rotational speed and time, and the parameters can be preset at any time.
  • It can be operated conveniently by keystroke. The measurement result is displayed. The preset and real data can be displayed alternately in time.
  • Automation: auto-test, auto-diagnose, auto-alarm.
  • It can test by self and alarm automatically. The dissolution parameters of' Chinese codex 2020' are stored in and can be taken out at anytime.
  • Time can be preset at many points. The beeper sounds automatically to any point, and then the tester automatically runs to the next one.
Model RC-3DT RC-6DT RC-8DT
Testing Station 3 6 8
Speed Range 20~200 rpm 20~200 rpm 20~200 rpm
Speed Accuracy ±2rpm ±2rpm ±2rpm
Temperature Range Rt~45.0°C Rt~45.0°C Rt~45.0°C
Temperature Stability ±0.3°C ±0.3°C ±0.3°C
Preset Timing Nine Points 5~900 min 5~900 min 5~900 min
Time Accuracy ±0.5 mm ±0.5 mm ±0.5 mm
Paddle Radial Run-Out ±0.5 mm ±0.5 mm ±0.5 mm
Basket Radial Run-Out ±1.0 mm ±1.0 mm ±1.0 mm
Power Supply 220V/ 50Hz, 110V/ 60Hz 220V/ 50Hz, 110V/ 60Hz 220V/ 50Hz, 110V/ 60Hz
Power 600W 1200W 1200W
Dimension 465×370×540 mm 820×370×540 mm 610×530×540 mm

What is Dissolution?

Dissolution is a process in which dosage forms dissolve to form a solution and the amount of drug dissolved is determined by HPLC or other analytical methods.

Dissolution is a process in which a solute in the form of gas, liquid or solid form dissolves in a solvent to form a solution.

Explanation

The process of checking the rate at which drug dissolves in a liquid medium is known as dissolution.

When we take any dosage form orally it should properly dissolve in gastrointestinal fluid to release its active pharmaceutical ingredient and after proper dissolution of API it will reach the systemic circulation and its bioavailability will be increased.

To check the in vitro dissolution profile different types of dissolution apparatus are used for different dosage forms.

For solid dosage forms type 1 or type 2 dissolution apparatus are used where a tablet or capsule dissolves in the liquid medium and sampling of solution is done at specific time intervals to check the dissolution rate of drug

Disintegration VS Dissolution

Disintegration

Dissolution

It is a Physical Test.

It is a Chemical Test.

This test is Used for solid dosage forms

This test is Used for solid dosage forms, gases and liquids.

In this test Solid dosage forms breaks down into small fragments

In this test Dosage forms dissolve to form solution

In-vitro

In-vitro & In-Vivo

Relationship between Disintegration and Dissolution

Disintegration and dissolution are interrelated with each other.

There is an inverse relation between disintegration and dissolution.

If the disintegration time of solid dosage form is high the dissolution rate of that product will be low.

For getting a good dissolution profile the product should disintegrate rapidly.

Suppose we take a tablet and in the stomach, it does not properly disintegrate then its dissolution profile will be low and its bioavailability will also be low.