Manual Dissolution Tester (1/3 vessels)

Lorderan Manual Dissolution Tester, with LCD display. The head part of the Dissolution Tester can be turned over manual. The preset and real data could display alternately in time IQ/OQ documents included free of charge. It is manufactured in compliance to the USP and EP.
SKU: RC-1
Availability: In Stock
Regular price
$899.00
Regular price
Sale price
$899.00
Model: RC-1
Subtotal: $899.00
10 customers are viewing this product
Free Shipping

Free shipping from China on all orders (Door to Door)

Free Returns
If approved, you’ll be automatically refunded on your original payment method.
Manual Dissolution Tester (1/3 vessels) - Lorderan

Manual Dissolution Tester (1/3 vessels)

$899.00

Manual Dissolution Tester (1/3 vessels)

$899.00
Model: RC-1
For RC-1 
  • It has one vessels and one poles arranged on one line.
  • The head part of the instrument can be artificially turned over smoothly and flexibly.
  • The basket units and paddle units are made of imported stainless steel (SUS316L).
  • The magnetism-pumped circular water current can heat the system evenly, and the bath liquid can achieve an equal temperature.
  • A MPU is used in dissolution tester to automatically control the temperature, rotational speed and time, and the parameters can be preset at any time.
  • It can be operated conveniently by keystroke. The measurement result is displayed and the preset and real data can be displayed alternately in time.
  • Automation: auto-test, auto-diagnose, auto-alarm.
For RC-3
  • It has 3 vessels and 3 poles arranged on one line.
  • The head can be artificially turned over smoothly and flexibly.
  • The basket units and paddle units are made of imported stainless steel (SUS316L).
  • The magnetism-pumped circular water current can heat the system evenly, and the bath liquid can achieve an equal temperature.
  • A MPU is used in dissolution tester to automatically control the temperature, rotational speed and time, and the parameters can be preset at any time.
  • It can be operated conveniently by keystroke. The measurement result is displayed, and the preset and real data can be displayed alternately in time.
  • Automation: auto-test, auto-diagnose, auto-alarm.
    Model RC-1 RC-3 RC-6 RC-8
    Testing Station 1 3 6 6
    Speed Range 20~200 rpm 20~200 rpm 20~200 rpm 20~200 rpm
    Speed Accuracy ±2rpm ±2rpm ±2rpm ±2rpm
    Temperature Range Rt~45.0°C Rt~45.0°C Rt~45.0°C Rt~45.0°C
    Temperature Stability ±0.3°C ±0.3°C ±0.3°C ±0.3°C
    Preset Timing Nine Points 5~900 min 5~900 min 5~900 min 5~900 min
    Time Accuracy ±0.5 mm ±0.5 mm ±0.5 mm ±0.5 mm
    Paddle Radial Run-Out ±0.5 mm ±0.5 mm ±0.5 mm ±0.5 mm
    Basket Radial Run-Out ±1.0 mm ±1.0 mm ±1.0 mm ±1.0 mm
    Power Supply 220V/ 50Hz, 110V/ 60Hz 220V/ 50Hz, 110V/ 60Hz 220V/ 50Hz, 110V/ 60Hz 220V/ 50Hz, 110V/ 60Hz
    Power 600W 600W 1200W 1200W
    Dimension 260×300×480 mm 510×300×480 mm 960×320×480 mm 960×440×480 mm

    What is Dissolution?

    Dissolution is a process in which dosage forms dissolve to form a solution and the amount of drug dissolved is determined by HPLC or other analytical methods.

    Dissolution is a process in which a solute in the form of gas, liquid or solid form dissolves in a solvent to form a solution.

    Explanation

    The process of checking the rate at which drug dissolves in a liquid medium is known as dissolution.

    When we take any dosage form orally it should properly dissolve in gastrointestinal fluid to release its active pharmaceutical ingredient and after proper dissolution of API it will reach the systemic circulation and its bioavailability will be increased.

    To check the in vitro dissolution profile different types of dissolution apparatus are used for different dosage forms.

    For solid dosage forms type 1 or type 2 dissolution apparatus are used where a tablet or capsule dissolves in the liquid medium and sampling of solution is done at specific time intervals to check the dissolution rate of drug

    Disintegration VS Dissolution

    Disintegration

    Dissolution

    It is a Physical Test.

    It is a Chemical Test.

    This test is Used for solid dosage forms

    This test is Used for solid dosage forms, gases and liquids.

    In this test Solid dosage forms breaks down into small fragments

    In this test Dosage forms dissolve to form solution

    In-vitro

    In-vitro & In-Vivo

    Relationship between Disintegration and Dissolution

    Disintegration and dissolution are interrelated with each other.

    There is an inverse relation between disintegration and dissolution.

    If the disintegration time of solid dosage form is high the dissolution rate of that product will be low.

    For getting a good dissolution profile the product should disintegrate rapidly.

    Suppose we take a tablet and in the stomach, it does not properly disintegrate then its dissolution profile will be low and its bioavailability will also be low.

    Related Products

    Recently Viewed Products