LORDERAN Class II A2 Biological Safety Cabinet with Motorized Front Window, 99.9995% Efficient ULPA Filter Biosafety Hood
- SKU
- 1100IIA2-X-110
- Availability
- In stock
- Brand
- LORDERAN
A Class II A2 biological safety cabinet that protects three things at once: you, your sample and the lab. Room air is drawn in at the front at 0.53 m/s, ULPA-filtered air falls over the work at 0.33 m/s, and 30% leaves through a second ULPA filter. Four widths from 3 ft to 5.3 ft, a motorized front window and a 3-year warranty.
Three protections in one airflow
Inflow at the front shields you. ULPA-filtered downflow keeps the sample clean. The 30% that leaves passes an exhaust ULPA filter, so the lab stays clean too, with no duct required.
- Inflow and downflow are monitored in real time by an airflow sensor.
- Alarms sound for abnormal airflow, filter change and an unsafe window height.
- Interlocks stop the UV lamp while the window is open or the LED lamp is on.
- Filter life is tracked by pressure sensors.
Specifications
Models 1100IIA2-X, 1300IIA2-X, 1500IIA2-X and 1800IIA2-X, each available in 110 V and 220 V versions.
Download the full catalog (PDF)Differs between models
| Model | 1100IIA2-X | 1300IIA2-X | 1500IIA2-X | 1800IIA2-X |
|---|---|---|---|---|
| Dimensions | ||||
| External Dims(W*D*H) | 1100*755*2200mm | 1300*755*2200mm | 1500*755*2200mm | 1800*755*2200mm |
| Internal Dims(W*D*H) | 940*600*660mm | 1150*600*660mm | 1350*600*660mm | 1625*600*660mm |
| Tested Opening (Safety Height) | 200mm(8') | |||
| Max Opening | 480mm (19‘') | |||
| Gross Weight | 220kg | 280Kg | 316Kg | 366Kg |
| Package Size(W*D*H) | 1220*1000*1820mm | 1460*1000*1820mm | 1630*1000*1820mm | 1900*1000*1820mm |
| Airflow and filtration | ||||
| CFM | 360m³/h | 440m³/h | 520m³/h | 620m³/h |
| Inflow Velocity | 0.53±0.025 m/s | |||
| Down Flow Velocity | 0.33±0.025 m/s | |||
| Airflow System | 70% air recirculation, 30% air exhaust | |||
| ULPA Filter | 2*ULPA Filter | |||
| Cabinet and electrical | ||||
| Front Window | Motorized, Anti UV | |||
| Noise | ≤67dB(A) | |||
| Consumption | 600W | 800W | 1300W | 1300W |
| Socket | Two, total load: 500W | |||
| Standard Accessory | LED lamp*2, UV lamp*2, Base stand, Remote control, Foot switch, Drain valve, Waterproof sockets*2 | |||
Choose a size
All widths share the same airflow, filters and controls. Front elevations drawn to the same scale.
Built for safe, comfortable daily work
The features you use every session, designed to keep the cabinet safe and simple to run.
ULPA filtration
Two ULPA filters at 99.9995% for 0.12 μm particles: about 10 times the efficiency of HEPA, for an ISO Class 3 work zone.
Real-time display
Filter life, fan run time and UV lamp run time, with an alarm below 10% remaining filter life.
Motorized front window
Raise and lower the sash with one hand, and clean the upper glass easily.
Time reserve
Schedule start-up and sterilizing so you skip about 30 minutes of waiting before and after work.
Audible and visual alarms
Warnings for abnormal airflow, filter change and an unsafe front window height.
Safety interlocks
UV lamp with front window, UV lamp with LED lamp, and blower with front window.
Remote control
Run the main functions from up to 6 meters away.
Ergonomic design
10° inclined viewing angle, raised arm rest and an anti-leakage work surface.
What's in the box
Delivered ready to work, with the accessories below as standard.
Which biosafety cabinet is right for you?
Every LORDERAN Class II cabinet protects the operator, the sample and the environment. Choose by airflow type, size and controller.
Questions buyers ask
Straight answers before you order.
Do I need to connect a duct?
No. A Class II A2 cabinet recirculates 70% of the air and discharges 30% through an ULPA exhaust filter, so it can run without a duct.
When should I choose a B2 cabinet instead?
If your biological work also involves volatile toxic chemicals or radionuclides, choose a Class II B2 total-exhaust cabinet, which recirculates no air.
Which voltage should I order?
Every model is offered in 110 V and 220 V versions. Choose the one that matches the sockets in your lab.
How do I know when the filter needs changing?
The controller tracks filter life and warns you with an audible and visual alarm when the filter needs to be changed.
What does the warranty cover?
The cabinet has a 3-year warranty. Major defects under warranty are covered by a full refund or replacement, and new, unopened items can be returned within 30 days.
Download documents
Catalogs and manuals as PDF files.
Free shipping
Free shipping on all orders, with some international restrictions.
3-year warranty
3-year warranty. Major defects under warranty are covered by a full refund or replacement.
30-day money back
Return most new, unopened items within 30 days.
DDP shipping
Delivered duty paid, so there are no surprise import charges on arrival.