LORDERAN Class II B2 Biological Safety Cabinet, 100% Total Exhaust Biosafety Hood with ULPA Filter and Motorized Front Window
- SKU
- 1100IIB2-X-110
- Availability
- In stock
- Questions
A Class II B2 total-exhaust biological safety cabinet for biological work that also involves volatile toxic chemicals or radionuclides. Nothing is recirculated: room air enters at 0.53 m/s, ULPA-filtered downflow protects the work at 0.33 m/s, and all of it leaves through a dedicated duct. Widths from 3 ft to 5.5 ft, with a motorized front window. Plan for the duct, its exhaust blower and the room air it removes.
Do I need a duct?
Yes. All air is exhausted through a dedicated duct to the outside. A 4 m PVC duct, Φ300 mm, is listed for every model.
A2 or B2?
B2 when biological work also involves volatile toxic chemicals or radionuclides. Nothing is recirculated into the work zone or the room.
When do the filters need changing?
Pressure sensors track filter life, and the controller warns you with an audible and visual alarm.
Which power does it need?
110 V or 220 V, offered for every model. Choose the voltage in the configurator.
Total exhaust, zero recirculation
Every litre of air drawn into the cabinet is exhausted to the outside. That is why a B2 cabinet is the usual choice when biological work also involves volatile toxic chemicals or radionuclides.
- Inflow and downflow are monitored in real time by an airflow sensor.
- Alarms sound for abnormal airflow, filter change and an unsafe window height.
- Interlocks stop the UV lamp while the window is open or the LED lamp is on.
- Filter life is tracked by pressure sensors.
Work at the tested opening
The protective air curtain is set and tested with the front window at 200 mm. Open it wider only to load or clean; the controller sounds an alarm when the window is above the safe height. The UV lamp runs only with the window closed.
How much air leaves the building
A B2 cabinet exhausts everything it moves: the room air drawn in at the front and the filtered downflow. For the 1100IIB2-X that is about 1050 m³/h, which the building’s supply air has to replace.
Downflow area estimated from the interior width and depth. Plan the exhaust duct and the room’s supply air for the listed volume of the model you choose.
Specifications
Models 1100IIB2-X, 1300IIB2-X, 1500IIB2-X and 1800IIB2-X, each available in 110 V and 220 V versions.
Download the full catalog (PDF)Differs between models
| Model | 1100IIB2-X | 1300IIB2-X | 1500IIB2-X | 1800IIB2-X |
|---|---|---|---|---|
| Dimensions | ||||
| External Dims (W × D × H) | 1100 × 775 × 2250 mm | 1300 × 775 × 2250 mm | 1500 × 775 × 2250 mm | 1800 × 775 × 2250 mm |
| Internal Dims(W × D × H) | 940 × 600 × 660 mm | 1150 × 600 × 660 mm | 1350 × 600 × 660 mm | 1670 × 600 × 660 mm |
| Tested Opening (Safety Height) | 200 mm (8 in) | |||
| Max Opening | 480 mm (19 in) | 480 mm (19 in) | 480 mm (19 in) | 480 mm (19 in) |
| Work Surface Height | 750 mm | |||
| Gross Weight | 240 kg | 280 kg | 300 kg | 408 kg |
| Package (Main Body) | 1220 × 1000* 1820 mm | 1460 × 1000 × 1820 mm | 1630 × 1000 × 1820 mm | 1930 × 1000 × 1820 mm |
| Package (Base Cabinet) | 970 × 810 × 630 mm | 970 × 810 × 630 mm | 970 × 810 × 630 mm | 920 × 710 × 680 mm |
| Airflow and filtration | ||||
| Inflow Velocity | 0.53 ± 0.025 m/s | |||
| Down Flow Velocity | 0.33 ± 0.025 m/s | |||
| CFM | 100%, 1050 m3/h | 100%, 1150 m3/h | 100%, 1270 m3/h | 100%, 1800 m3/h |
| Airflow System | 0% air recirculation, 100% air exhaust | 0% air recirculation, 100% air exhaust | 0% air recirculation, 100% air exhaust | 0% air recirculation, 100% air exhaust |
| Exhaust Duct | 4 meters PVC duct, Dia 300 mm | |||
| ULPA Filter | ULPA Filter*2 | |||
| Cabinet and electrical | ||||
| Front Window | Motorized, Anti UV | |||
| Noise | ≤ 67 dB(A) | |||
| Consumption | 600 W | 800 W | 1300 W | 1400 W |
| Socket | Two, total load: 500 W | |||
| Standard Accessory | LED lamp*2, UV lamp*2, base stand, remote control, foot switch, exhaust blower, exhaust duct, drain valve, waterproof sockets*2, pipe strap*2 | LED lamp*2, UV lamp*2, base stand, remote control, foot switch, exhaust blower, exhaust duct, drain valve, waterproof sockets*2, pipe strap*2 | LED lamp*2, UV lamp*2, base stand, remote control, foot switch, exhaust blower, exhaust duct, drain valve, waterproof sockets*2, pipe strap*2 | LED lamp*2, UV lamp*2, base stand, remote control, foot switch, exhaust blower, exhaust duct, drain valve, waterproof sockets*2, pipe strap*2 |
Choose a size
All widths share the same airflow, filters and controls. Front elevations drawn to the same scale.
Built for safe, comfortable daily work
The features you use every session, designed to keep the cabinet safe and simple to run.
100% total exhaust
No air is recirculated: everything drawn in leaves the cabinet through the exhaust system.
ULPA filtration
Two ULPA filters at 99.9995% for 0.12 μm particles: about 10 times the efficiency of HEPA, for an ISO Class 3 work zone.
Real-time display
Filter life, fan run time and UV lamp run time, with an alarm below 10% remaining filter life.
Motorized front window
Raise and lower the sash with one hand, and clean the upper glass easily.
Audible and visual alarms
Warnings for abnormal airflow, filter change and an unsafe front window height.
Safety interlocks
UV lamp with front window, UV lamp with LED lamp, and blower with front window.
Remote control
Run the main functions from up to 6 meters away.
Foot switch
Adjust the window height without lifting your hands from the work.
What's in the box
Delivered ready to work, with the accessories below as standard.
Which biosafety cabinet is right for you?
Every LORDERAN Class II cabinet protects the operator, the sample and the environment. Choose by airflow type, size and controller.
Questions buyers ask
UV, warranty, returns, delivery and quotes.
What does the warranty cover?
A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. ULPA and HEPA filters, seals and other wear parts are excluded.
When can the UV lamp run?
Between sessions, to disinfect exposed surfaces. Interlocks stop it while the window is open or the LED lamp is on, so it runs only with the window closed and the work light off.
Can I return it?
Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.
How is it delivered, and when does it ship?
Freight, duties and taxes are paid to your loading dock; moving the cabinet inside is not included. Your confirmed ship date is included in the order acknowledgement.
Can I get a formal quote for a purchase order?
Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.