Steam Sterilizer

LORDERAN Lab Steam Autoclave Sterilizer with Condensate Exhaust Bottle, Solid/Liquid & Agar Melting Modes, Zero Steam Emission

SKU
N-35X
Availability
In stock
Questions

Ask about this instrument

LORDERAN Lab Steam Autoclave Sterilizer with Condensate Exhaust Bottle, Solid/Liquid & Agar Melting Modes, Zero Steam Emission

An engineer replies by email or phone, usually within 12 hours.

Volume · 35L
Power · 220V

A laboratory autoclave with a programme for every load: solid, liquid, agar melting and a custom mode. Exhaust steam and air are condensed in a built-in bottle, so nothing is vented into the lab. Drying, keep-warm, a built-in printer and calibration ports come as standard. Four sizes from 35 to 100 L.

Solid, liquid, agar modesZero steam emissionBuilt-in printerIQ/OQ/PQ ports1-year warranty
LORDERAN121.0°CSteam to waterAgar meltingZero steamPrinter
106–134 °Csterilizing range
4 modessolid, liquid, agar, custom
Zerosteam vented into the lab
1–999 minsterilization timer
35–100 Lfour sizes
Microbiology labsCulture mediaAgar preparationGlassware and instrumentsLab waste
1-year warrantyMajor defects: full refund or replacement.
Free shipping, DDPDuties paid, no surprise import charges.
30-day money backReturn most new, unopened items.
110 V or 220 VChoose the supply that matches your lab.
TECHNICAL DATASHEET · PDF · 6 PAGES

35–100 L Lab Autoclave with Condensate Bottle datasheet

Full specifications, the sterilization cycle, saturated steam and F0 reference values, installation and warranty in one document to share with your team.
Download datasheet

One autoclave, four programmes

Pick the mode for the load. The controller handles exhaust speed, timing and holding temperature.

M1 SolidMetal instruments, glassware and unwrapped tools.
M2 LiquidCulture media and solutions, with slower exhaust to prevent boil-over.
M3 Melt and holdMelt agar at 60–100 °C, then hold it at 45–60 °C so it stays liquid.
CustomSet your own temperature, time and pressure.

Specifications

Models N-35X, N-50X, N-75X and N-100X, each available in 110 V and 220 V versions.

Differs between models

Model 35L 50L 75L 100L
Model
SKU N-35X N-50X N-75X N-100X
Performance
Working pressure 33psi (0.23mpa)
Max temperature 134℃
Temp. setting range 106~134℃ (222.8~273°F)
Heat average ≤0.5℃
Sterilization timer range 1~999mins
Drying timer range 0~240mins
Chamber and loading
Inner chamber capacity φ300x450mm φ350x515mm φ400x585mm φ450x615mm
Baskets quantity 1*(φ275x395mm) 2*(φ325x235) 2*(φ375x265) 2*(φ425x275)
Operation
Exhaust method Automatic internal exhaust
Drainage Manual drainage
Electrical
Power 2.5kw, 12amps(220V), 21amps (120V) 3kw, 13.6amps(220V), 25amps (120V) 4.5kw, 20.5amps(220V), 37.5amps (120V) 4.5kw, 20.5amps(220V), 37.5amps (120V)
Dimensions and weight
Overall dimensions 430x610x1030mm 500x675x1100mm 540x716x1165mm 575x748x1255
G.W / N.W 90/74kg 125/97kg 145/114kg 161/129kg

Key technical parameters

The controller settings, as listed for this autoclave.

Show all 15 parameters: temperatures, times and exhaust
106–134℃Sterilize temperature
1–999 minSterilize time
0.1℃Temperature resolution
60–100℃Melting temperature
45–60℃Holding temperature
≤0.5℃Temperature fluctuation
1–999 minMelting time
1–999 minHolding time
0–240 minDrying time
0–250 sExhaust interval
0–60 sExhaust time
0–9Exhaust times
100–110℃Displace temperature
0.3 MPaDesign pressure
0.24 MPaMax working pressure

Choose a size

Same modes and safety on every size. Drawn to the same scale; the dashed outline is the inner chamber.

35L430 × 610 × 1030 mmchamber φ300 × 45050L500 × 675 × 1100 mmchamber φ350 × 51575L540 × 716 × 1165 mmchamber φ400 × 585100L575 × 748 × 1255 mmchamber φ450 × 615Dashed outline: inner chamber, drawn to the same scale

Made for unattended, mess-free work

Load in the evening, find sterile media and molten agar ready in the morning.

Zero steam emission

No steam is vented into the lab during air removal or depressurization.

Built-in condensate bottle

Exhausted steam and air condense back into water inside the unit.

Keep warm 45–60 °C

Holds the load warm automatically after sterilization.

Standard drying

0 to 240 minutes to reduce residual moisture.

Multi-stage exhaust

Set exhaust interval, time and number of pulses.

Built-in printer

A printed record of every cycle.

Calibration ports

Temperature and pressure ports compatible with 3Q IQ/OQ/PQ adapters.

Safety interlock

With memory storage and downward internal steam circulation.

Find the right LORDERAN autoclave

Compare the range by capacity, exhaust and special functions.

Questions buyers ask

Straight answers before you order.

Can it melt agar?

Yes. Mode M3 melts agar at 60 to 100 °C and then holds it at 45 to 60 °C so it does not set before you pour.

How does it handle liquids?

Mode M2 uses a slower exhaust to prevent boil-over in media and solutions.

Will steam escape into the lab?

No. Steam and air are condensed in the built-in bottle.

Can I validate it?

The inspection interface has temperature and pressure calibration ports compatible with 3Q IQ/OQ/PQ adapters, and the built-in printer records each cycle.

What does the warranty cover?

A 1-year warranty. Major defects under warranty are covered by a full refund or replacement.

Free shipping

Free shipping on all orders, with some international restrictions.

1-year warranty

1-year warranty. Major defects under warranty are covered by a full refund or replacement.

30-day money back

Return most new, unopened items within 30 days.

DDP shipping

Delivered duty paid, so there are no surprise import charges on arrival.