Free shipping from China on all orders (Door to Door)
We can ship to worldwide. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
Learn more from our shippling policy https://www.lorderan.com/policies/shipping-policy
You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).
You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper, the time it takes us to process your return once we receive it, and the time it takes your bank to process our refund request (3 to 5 business days).
If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item. Learn more from our refund policy https://www.lorderan.com/policies/refund-policy
Delivered duty paid (DDP Term) shipping is a type of delivery where Lorderan paying for all charges including freight, duties, taxes, customs clearance charges up to the customer's door, warehouse or fulfillment center.
Compact, Powerful, Reliable
Automatic high-pressure steam sterilization
Full stainless steel 304 structure
Plug & Play Installation
Reliable Performance
Excellent value for money
Easy To Replace Parts
Small foot print
LED display
Leakage breaker
Built-in exhaust bottle
up to 136℃
Safety valve
Auto-exhaust
Easy setting
Built-in voltage regulator
Full SS304
Fully automatic
Anti-dry burning
Large load
Built-in cooling fan
Overpressure protection
We solicited thousands of surveys from real users to optimize all the features and details that needed improvement
Control System
Remove complexity and simplify, no threshold for use, dramatically reducing the failure rate.
Pressure Gauge
Adopts the psi scale gauge that American users are more accustomed to, with accurate values.
Heating Elements
Independent audible and visual alarm system for each of the three heating elements for easy troubleshooting and replacement.
Wiring
The wiring system has been upgraded to simplify wiring and layout and reduce heat sources.
Control System
Remove complexity and simplify, no threshold for use, dramatically reducing the failure rate.
Pressure Gauge
Adopts the psi scale gauge that American users are more accustomed to, with accurate values.
Exhaust Bottle
Built-in exhaust bottle, no indoor steam pollution or hot steam burns anymore.
Voltage Stabilizer
Built-in voltage stabilizer, for the city voltage instability of the users to provide voltage and autoclave double protection, more secure and stable.
Heating Elements
Independent audible and visual alarm system for each of the three heating elements for easy troubleshooting and replacement.
Wiring
The wiring system has been upgraded to simplify wiring and layout and reduce heat sources.
Quality and Warranty
Based on a lot of real data feedback, the performance and stability have been improved. We provide a two-year warranty to make our users worry-free.
Plug
Come standard with NEMA 10-50P (110/220V) plug. Removable and replaceable.
Exhaust Bottle
Built-in exhaust bottle, no indoor steam pollution or hot steam burns anymore.
Voltage Stabilizer
Built-in voltage stabilizer, for the city voltage instability of the users to provide voltage and autoclave double protection, more secure and stable.
Quality and Warranty
Based on a lot of real data feedback, the performance and stability have been improved. We provide a two-year warranty to make our users worry-free.
Plug
Come standard with NEMA 10-50P (110/220V) plug. Removable and replaceable.
Lid is made of high quality stainless steel with interlocking mechanism to provide maximum safety and sealing.
Meanwhile, the heat-insulating lid is made of stainless steel for better heat insulation and anti-scald performance.
High efficient sealing, Self-expanding. Good sealing effect and long service life.
Adopts the psi scale.
Intuitive, comprehensive, and easy-to-understand.
Push-button, one-touch start.
Pour 1000ml of water into the drain bottle before use.
Made of stainless steel, it is not easy to be clogged. Drain the water by opening the valve after sterilization.
High-strength load-bearing, strong and wear-resistant. A single load can bear 100kg.
Model | VAS150 |
Chamber Dimensions | 150L (φ19.68″x 27.95″) |
Max Working Temperature | 134℃ |
Max Working Pressure | 33.36psi (0.23 Mpa) |
Heat Average | ≤0.5℃ |
Timer Range | 0-9999mins |
Adjustment of Temperature | 105~136℃ 50 ~65°C (pre-heating) / 65 ~102°C(heating) / 105~136°C (sterilization) |
Temperature Sensor | Flexible PT-100 temperature sensor |
Heating Element | 2000W x 3 units |
Exhaust | Water-cooled steam exhaust |
Cooling Fan | Axial fan motor |
Baskets Quantity (Dia*H) | Two (φ17.72″x 13.78″) |
Electrical Power | 6Kw, 220-240V, 27A, 60Hz, single phase 4.5KW, 110-125V, 40A, 60Hz, single phase |
Plug Type | NEMA 10-50P (220V), NEMA5-50P (110V) |
External Dimensions (W*D*H) | 25.6″×26.77″×41.73″ (650*680*1060mm) |
Packing Dimensions (W*D*H) | 27.95″×29.13″×47.24″ (710x740x1200mm) |
G.W / N.W | 135Kg / 117Kg |