Disintegration Tester

BJ-1
$330.00

Disintegration Tester with basket assembly, are used for detecting disintegration of solid in prescriptive conditions.
Used to automatically control the temperature, time and frequency of nacelle back and forth, preset and real time data can be displayed alternately in time.
IQ/OQ documents included free of charge.
It is manufactured in compliance to the USP and EP

Model :
BJ-1
BJ-2
BJ-3
$330.00
customers are viewing this product
For BJ-1
  1. There are 6 tubes in one basket assembly, auto stops at timing point.
  2. The bath liquid can achieve an even temperature.
  3. A MPU is used to automatically control the temperature, time and frequency of nacelle back and forth.
  4. Timing at will. The preset and real time data can be displayed alternately in time.
  5. Automation: auto-test, auto-diagnose, auto-alarm.
For BJ-2
  1. There are 12 tubes in 2 basket assemblies.
  2. Each test station is driven independently, auto stops at timing point.
  3. The bath liquid can achieve an even temperature.
  4. A MPU is used to automatically control the temperature, time and frequency of nacelle back and forth.
  5. Timing at will. The preset and real time data can be displayed alternately in time.
  6. Automation: auto-test, auto-diagnose, auto-alarm.
For BJ-3
  1. There are 18 tubes in 3 basket assembly.
  2. Each test station is driven independentlyauto stops at timing point.
  3. The bath liquid can achieve an even temperature.
  4. A MPU is used to automatically control the temperature, time and frequency of nacelle back and forth.
  5. Timing at will. The preset and real time data can be displayed alternately in time.
  6. Automation: auto-test, auto-diagnose, auto-alarm.
Model BJ-1 BJ-2 BJ-3
Testing Station 1 2 3
Speed 30~32 /min 30~32 /min 30~32 /min
Height of Stroke 55±1 mm 55±1 mm 55±1 mm
Timing Range 1~900 mins 1~900 mins 1~900 mins
Temperature Rt~45 °C Rt~45 °C Rt~45 °C
Accuracy of Temperature ±0.5 °C ±0.5 °C ±0.5 °C
Power Supply 220V/ 50Hz, 110V/ 60Hz 220V/ 50Hz, 110V/ 60Hz 220V/ 50Hz, 110V/ 60Hz
Power 600W 600W 600W
Dimension 260×300×420 mm 400×300×420 mm 540×300×420 mm

What is Disintegration?

Disintegration is the vitro test which is performed using basket rack assembly to check the rate at which the tablet breaks down into small fragments.

The process in which solid dosage forms when come in contact with fluid breaks down into small granules of fragments which pass through the mesh no #10 or 2.0±0.2 mm leaving behind no solid mass.

Explanation

Disintegration test is performed in vitro means outside the body to check that our tablets or solid dosage form breaks down properly into small fragments in a specified time period.

When we take a solid dosage form it should disintegrate properly inside the body to facilitate the process of drug release.

If we take a solid dosage form which does not disintegrate in the body will not produce the desired pharmacological effect.

The disintegration time can be adjusted using a class of excipients known as disintegrants and super disintegrants.

These disintegrants or super disintegrants break the bondings in solid dosage forms and facilitate the drug release.

What is disintegration time?

Disintegration time is the time required for a dosage form to break up in to granules of specified size (or smaller) under carefully specified conditions. ... In other words, DT (disintegration time) is measuring the breakdown of a dosage form and dissolution is measuring the drug being solubilized in the media.

The cookie settings on Lorderan website are set to 'allow all cookies' to give you the very best experience. Please click Accept Cookies to continue to use the site.