Environmental test chamber

LORDERAN Climate Chamber -70°C to 150°C, 20-98% RH, Temperature Humidity Test Chamber with Water Recirculation, IEC/ASTM, JS6 Series

SKU
JS6010
Availability
In stock
Questions

Ask about this instrument

LORDERAN Climate Chamber -70°C to 150°C, 20-98% RH, Temperature Humidity Test Chamber with Water Recirculation, IEC/ASTM, JS6 Series

An engineer replies by email or phone, usually within 12 hours.

Capacity · 100L

Cold, dry-heat and damp-heat tests down to −70 °C: −70 to 150 °C and 20 to 98 %RH in one chamber, in four sizes from 100 to 1000 L. The humidity you can reach depends on the temperature, so check your test points on the humidity chart before you choose.

Set point+25 °Croom temperature−70.0 °Ccascade cooling+150.0 °Cdry heat85.0 °C85 %RH, damp heat+150−70Cold, to −70 °CDry heat, to +150 °CDamp heat, to 98 %RHSet point+25 °Croom temperature−70.0 °Ccascade cooling+150.0 °Cdry heat85.0 °C85 %RH, damp heat+150ColdDry heatDamp heat
-70 → 150 °Ctemperature range
20–98 %RHhumidity range
±0.5 °Ctemperature fluctuation
±2–3 %RHhumidity fluctuation
100–1000 Lfour sizes
ElectronicsAutomotive partsCommunication equipmentInstrumentsPlastics and metals

Will it reach my humidity?

98 %RH from 20 to 70 °C, easing to 90 %RH at 90 °C; 20 %RH from 45 °C up. Drier or cooler points need the low-humidity function.

How cold, how fast?

−70 °C with two-stage cascade refrigeration, air-cooled. +20 to −40 °C in ≤ 70 min; +20 to +150 °C in ≤ 60 min.

Do I need a water line?

No. A 20 L tank of RO or DI water feeds the humidifier, and condensate drips back into it by gravity.

Which power does it need?

100 and 250 L: 208–240 V single-phase, or three-phase. 500 and 1000 L: three-phase, 208 to 480 V. All 50/60 Hz.

Climate chamber -70 °C to 150 °C documentsThe datasheet puts all four sizes, specifications and test standards on one sheet for your team. The user manual covers installation, programming, safety and maintenance.Download datasheet Download user manual

How it holds your test conditions

The samples sit in a sealed workspace. Everything that changes the air happens in a duct behind its back wall.

WorkspaceAir ductCable portSamples on shelvesComp.Cascade refrigeration: two compressors, air-cooledFanCooling coil (evaporator)HeaterHumidifier, makes steamWater tank (rear)Temperature and humidity sensorsTouch screenSet40.0 °C93 %RH12345Touch screenSet40.0 °C93 %RHWorkspaceAir duct, behind back wallCable portSamples on shelvesFanCooling coilHeaterHumidifierComp.Refrigeration unitcascade, air-cooledWater tank(rear, 20 L)Temperature/RH sensors12345

Simplified section, not to scale. Blue arrows show the air path. Screen values are an example.

  1. 1
    Load the samples.Space them out on the shelves so air reaches every side. Cables to powered samples go through the 100 mm port.
  2. 2
    Set the test.Enter temperature, humidity and time on the 7-inch touch screen, or pick one of 100 saved programs.
  3. 3
    Condition the air.A fan drives air through the duct: the cooling coil chills and dries it, the heater warms it, the humidifier adds steam.
  4. 4
    Measure and correct.Sensors read the air temperature and humidity, and the controller trims each part until the actual values match the set point.
  5. 5
    End the test.When the program ends, the chamber returns to room temperature to protect the samples.

Where temperature meets humidity

Relative humidity is the water in the air as a share of the most the air can hold, and that maximum climbs steeply with temperature: about 17 g per cubic metre at 20 °C, about 198 g at 70 °C. That is why the reachable humidity changes along the temperature axis. The coloured area is the standard working envelope; the hatched area needs the optional low-humidity function. Every labelled point is a published limit of the chamber.

01020304050607080901000102030405060708090100Temperature (°C)Relative humidity (%RH)STANDARD ZONE20 to 98 %RHLOW-RHoptional10 °C · 98 %10 °C · 98 %20 °C · 98 %20 °C · 98 %70 °C · 98 %70 °C · 98 %90 °C · 90 %90 °C · 90 %20 °C · 55 %20 °C · 55 %45 °C · 20 %45 °C · 20 %90 °C · 20 %90 °C · 20 %10 °C · 50 %10 °C · 50 %20 °C · 30 %20 °C · 30 %30 °C · 18 %30 °C · 18 %40 °C · 10 %40 °C · 10 %90 °C · 10 %90 °C · 10 %020406080100020406080100Standard range20–98 %RH98 %RH from 20 to 70 °C90 %55 %20 % from 45 °C10 % from 40 °C, optionLow-RH option%RHTemperature (°C)
Standard zoneLow-humidity zone, optional low-humidity function
98 %RHfrom 20 to 70 °C, easing to 90 %RH at 90 °C.
20 %RHstandard lower limit from 45 to 90 °C, rising toward 55 %RH at 20 °C.
10 %RHfrom 40 °C with the low-humidity function, also needed for any humidity test at 10–20 °C. Outside 10–90 °C: temperature only.

Specifications

Models JS6010, JS6025, JS6050 and JS6100.

Differs between models

Model 100 L 250 L 500 L 1000 L
Model and size
SKU JS6010 JS6025 JS6050 JS6100
Inner size (W × D × H) 500 × 400 × 500 mm 600 × 600 × 700 mm 800 × 700 × 900 mm 1000 × 1000 × 1000 mm
External size, casters included (W × D × H) 780 × 1130 × 1580 mm 960 × 1500 × 1760 mm 1130 × 1550 × 1950 mm 1320 × 1890 × 2050 mm
Shelves 2 2 3 3
Weight 250 kg 320 kg 500 kg 680 kg
Temperature and humidity
Temperature range −70 to 150 °C
Heating rate 2 to 3 °C/min
Cooling rate 0.7 to 1 °C/min
Humidity range 20 to 98 %RH
Temperature fluctuation ±0.5 °C
Temperature deviation ≤ ±2 °C
Temperature uniformity ≤ 2 °C
Humidity fluctuation ±2–3 %RH
Humidity deviation ±2.0 %RH above 75 %RH; ±3.0 %RH at 75 %RH or below
Humidity uniformity ≤ 5 %RH
Heating-up time 20 °C to +150 °C ≤ 60 min
Cooling down time +20 °C to −40 °C ≤ 70 min
Refrigeration, control and power
Refrigeration Cascade (two stages), air-cooled
Refrigerant R449A and R23A
Display 7-inch touch screen, 100 programs × 100 steps
Noise level 60 to 65 dB 60 to 65 dB 65 to 70 dB 65 to 70 dB
Power supply 208–240 V 1-phase, or 3-phase: 208, 220–240, 400, 415 or 480 V; 50/60 Hz 208–240 V 1-phase, or 3-phase: 208, 220–240, 400, 415 or 480 V; 50/60 Hz 3-phase: 208, 220–240, 400, 415 or 480 V; 50/60 Hz 3-phase: 208, 220–240, 400, 415 or 480 V; 50/60 Hz
Power 7 kW · 32 A at 220 V, 1-phase 8 kW · 36 A at 220 V, 1-phase 11 kW · 34 A at 220 V, 15.6 A at 480 V 14 kW · 36.7 A at 220 V, 16.8 A at 480 V

Choose a size

All four sizes share the same range, controller and protection. Front elevations drawn to the same scale; heights include the casters.

100L · JS6010780 mm500×400×500 inside250L · JS6025960 mm600×600×700 inside500L · JS60501130 mm800×700×900 inside1000L · JS61001320 mm1000×1000×1000 insideJS6010780 × 1580 mmJS6025960 × 1760 mmJS60501130 × 1950 mmJS61001320 × 2050 mm

Which test profiles can you run?

From a single set point to a full cyclic profile with heating, cooling, humidifying and dehumidifying.

Single temperature

Temperature only, with humidity control switched off.

Constant temperature and humidity

Hold a fixed temperature and a fixed humidity for as long as you need.

Programmed cycles

Multi-step profiles that repeat automatically, up to 100 programs of 100 steps.

Amber: temperature. Blue dashed: humidity.

How it reaches −70 °C

One refrigerant cannot cover the whole span efficiently, so two circuits work in series. The high stage (R449A) rejects heat to the room; its evaporator is the condenser of the low stage (R23A), which can then boil cold enough to pull the chamber air down to −70 °C. Both stages are air-cooled, so no cooling water is needed.

HSLSCondenserEvaporatorHigh stageR449A · heat out to the room, air-cooledLow stageR23A · cools the chamber air, to −70 °CCascade exchanger: the high stage cools the low stageCascade exchangerHSLSCondenserEvaporatorHigh stage, R449A: heat out to the roomLow stage, R23A: cools the chamber to −70 °C

Simplified schematic, not to scale. Dashed lines show refrigerant flow in each stage.

Water recirculation: a closed loop

Steam comes from purified water in a 20 L tank behind the rear cover. Water the cooling coil pulls out of the air drips back into the tank by gravity, so most of it is used again and no water line is needed.

steamhumid airdrips backby gravityfeedWorkspacesteam humidifies the airHumidifierboils water to steamCooling coilcondenses water outWater tank, 20 LRO or DI water, fill ½–¾Overflow outlet: surplus only, to a traysteamhumid airdrips backby gravityfeedWorkspacesteam humidifies the airHumidifierboils water to steamCooling coilcondenses water outWater tank, 20 LRO or DI water, fill ½–¾Overflow outlet: surplus only, to a tray
Tank
20 L, built in
One fill
up to about 7 days in normal use
Water
RO or DI only, ≤ 5 µS/cm; never tap water
Reuse
over 80% higher water utilization*

*Manufacturer figure, compared with a chamber that drains its condensate. Long high-humidity tests use more water. Automatic top-up from a purified-water supply is available on request.

Engineered for months of continuous testing

The parts that decide whether a long test finishes: compressor, controls, seals and build.

Tecumseh, Bitzer or GEA BOCK compressors

Protected against motor overheating and over-pressure, and mounted on vibration dampers.

7-inch touch screen

Time-segment and real-time programming, 100 programs × 100 steps.

Remote PC control

Live curves, compressor status and alarms over the network.

No dripping condensation

Air circulation keeps the chamber ceiling dry, so no water drips onto samples in hot, humid tests.

Auto-return to ambient

After a program ends the chamber returns to room temperature to protect samples.

Frost-free sealing

Double silicone seals for more than 1000 hours of frost-free running.

SUS304 inside and out

2 mm fully welded inner chamber, 1.5 mm outer shell, PU foam and rock wool insulation.

Heated viewing window

Double glass with a heater, plus a 100 mm cable port for live testing.

Safety and standards

Protection for the sample, the refrigeration system and the operator.

Show all 10 safety protections
  • Sample over-temperature protection
  • Motor overload protection
  • Compressor overload protection
  • Compressor over-pressure protection
  • Humidifier dry-burn protection
  • Water shortage protection
  • Phase loss and reversal protection
  • Electrical leakage protection
  • Three-color alarm light
  • Flame-retardant non-metallic materials
Show the reference standards: IEC 60068, GB/T, GJB150
IEC 60068 test methodsGB/T and GB test specificationsGJB150 high-temperature testsGJB150 low-temperature testsGJB150 damp heat tests

Find the right LORDERAN environmental chamber

Steady climate, fast ramps or instant shock: choose by how your product must be stressed.

Chamber
Climate −70 °CThis product
Temperature
-40 to 150 °C
-70 to 150 °C
-70 to 150 °C
-65 to 200 °C
Humidity
20–98 %RH
20–98 %RH
20–98 %RH
No
Rate of change
2–3 °C/min up, 0.7–1 °C/min down
2–3 °C/min up, 0.7–1 °C/min down
5, 10 or 15 °C/min
Zone transfer within 15 s
Sizes
100–1000 L
100–1000 L
100–1000 L
50–200 L

Questions buyers ask

Options, warranty, returns, delivery and quotes.

How low can the humidity go?

20 %RH as standard from 45 °C upward. With the optional low-humidity function, down to 10 %RH from 40 °C; the function is also needed for any humidity test at 10–20 °C. Tell us your test temperature when you order and we tune the system before shipping.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded. A 2-year extended warranty can be added in the configurator.

Can I add shelves or a larger test hole?

Yes. Additional shelves and a custom test hole can be added in the configurator. If a custom hole could affect the door or wall sealing, we contact you before production.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the chamber inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose size, voltage and options

The price, delivery date and PDF quote update with your choices.

Configure yours