LORDERAN Climate Chamber -70°C to 150°C, 20-98% RH, Temperature Humidity Test Chamber with Water Recirculation, IEC/ASTM, JS6 Series
- SKU
- JS6010
- Availability
- In stock
- Questions
Cold, dry-heat and damp-heat tests down to −70 °C: −70 to 150 °C and 20 to 98 %RH in one chamber, in four sizes from 100 to 1000 L. The humidity you can reach depends on the temperature, so check your test points on the humidity chart before you choose.
Will it reach my humidity?
98 %RH from 20 to 70 °C, easing to 90 %RH at 90 °C; 20 %RH from 45 °C up. Drier or cooler points need the low-humidity function.
How cold, how fast?
−70 °C with two-stage cascade refrigeration, air-cooled. +20 to −40 °C in ≤ 70 min; +20 to +150 °C in ≤ 60 min.
Do I need a water line?
No. A 20 L tank of RO or DI water feeds the humidifier, and condensate drips back into it by gravity.
Which power does it need?
100 and 250 L: 208–240 V single-phase, or three-phase. 500 and 1000 L: three-phase, 208 to 480 V. All 50/60 Hz.
How it holds your test conditions
The samples sit in a sealed workspace. Everything that changes the air happens in a duct behind its back wall.
Simplified section, not to scale. Blue arrows show the air path. Screen values are an example.
-
1Load the samples.Space them out on the shelves so air reaches every side. Cables to powered samples go through the 100 mm port.
-
2Set the test.Enter temperature, humidity and time on the 7-inch touch screen, or pick one of 100 saved programs.
-
3Condition the air.A fan drives air through the duct: the cooling coil chills and dries it, the heater warms it, the humidifier adds steam.
-
4Measure and correct.Sensors read the air temperature and humidity, and the controller trims each part until the actual values match the set point.
-
5End the test.When the program ends, the chamber returns to room temperature to protect the samples.
Where temperature meets humidity
Relative humidity is the water in the air as a share of the most the air can hold, and that maximum climbs steeply with temperature: about 17 g per cubic metre at 20 °C, about 198 g at 70 °C. That is why the reachable humidity changes along the temperature axis. The coloured area is the standard working envelope; the hatched area needs the optional low-humidity function. Every labelled point is a published limit of the chamber.
Specifications
Models JS6010, JS6025, JS6050 and JS6100.
Differs between models
| Model | 100 L | 250 L | 500 L | 1000 L |
|---|---|---|---|---|
| Model and size | ||||
| SKU | JS6010 | JS6025 | JS6050 | JS6100 |
| Inner size (W × D × H) | 500 × 400 × 500 mm | 600 × 600 × 700 mm | 800 × 700 × 900 mm | 1000 × 1000 × 1000 mm |
| External size, casters included (W × D × H) | 780 × 1130 × 1580 mm | 960 × 1500 × 1760 mm | 1130 × 1550 × 1950 mm | 1320 × 1890 × 2050 mm |
| Shelves | 2 | 2 | 3 | 3 |
| Weight | 250 kg | 320 kg | 500 kg | 680 kg |
| Temperature and humidity | ||||
| Temperature range | −70 to 150 °C | |||
| Heating rate | 2 to 3 °C/min | |||
| Cooling rate | 0.7 to 1 °C/min | |||
| Humidity range | 20 to 98 %RH | |||
| Temperature fluctuation | ±0.5 °C | |||
| Temperature deviation | ≤ ±2 °C | |||
| Temperature uniformity | ≤ 2 °C | |||
| Humidity fluctuation | ±2–3 %RH | |||
| Humidity deviation | ±2.0 %RH above 75 %RH; ±3.0 %RH at 75 %RH or below | |||
| Humidity uniformity | ≤ 5 %RH | |||
| Heating-up time | 20 °C to +150 °C ≤ 60 min | |||
| Cooling down time | +20 °C to −40 °C ≤ 70 min | |||
| Refrigeration, control and power | ||||
| Refrigeration | Cascade (two stages), air-cooled | |||
| Refrigerant | R449A and R23A | |||
| Display | 7-inch touch screen, 100 programs × 100 steps | |||
| Noise level | 60 to 65 dB | 60 to 65 dB | 65 to 70 dB | 65 to 70 dB |
| Power supply | 208–240 V 1-phase, or 3-phase: 208, 220–240, 400, 415 or 480 V; 50/60 Hz | 208–240 V 1-phase, or 3-phase: 208, 220–240, 400, 415 or 480 V; 50/60 Hz | 3-phase: 208, 220–240, 400, 415 or 480 V; 50/60 Hz | 3-phase: 208, 220–240, 400, 415 or 480 V; 50/60 Hz |
| Power | 7 kW · 32 A at 220 V, 1-phase | 8 kW · 36 A at 220 V, 1-phase | 11 kW · 34 A at 220 V, 15.6 A at 480 V | 14 kW · 36.7 A at 220 V, 16.8 A at 480 V |
Choose a size
All four sizes share the same range, controller and protection. Front elevations drawn to the same scale; heights include the casters.
Which test profiles can you run?
From a single set point to a full cyclic profile with heating, cooling, humidifying and dehumidifying.
Single temperature
Temperature only, with humidity control switched off.
Constant temperature and humidity
Hold a fixed temperature and a fixed humidity for as long as you need.
Programmed cycles
Multi-step profiles that repeat automatically, up to 100 programs of 100 steps.
Amber: temperature. Blue dashed: humidity.
How it reaches −70 °C
One refrigerant cannot cover the whole span efficiently, so two circuits work in series. The high stage (R449A) rejects heat to the room; its evaporator is the condenser of the low stage (R23A), which can then boil cold enough to pull the chamber air down to −70 °C. Both stages are air-cooled, so no cooling water is needed.
Simplified schematic, not to scale. Dashed lines show refrigerant flow in each stage.
Water recirculation: a closed loop
Steam comes from purified water in a 20 L tank behind the rear cover. Water the cooling coil pulls out of the air drips back into the tank by gravity, so most of it is used again and no water line is needed.
- Tank
- 20 L, built in
- One fill
- up to about 7 days in normal use
- Water
- RO or DI only, ≤ 5 µS/cm; never tap water
- Reuse
- over 80% higher water utilization*
*Manufacturer figure, compared with a chamber that drains its condensate. Long high-humidity tests use more water. Automatic top-up from a purified-water supply is available on request.
Engineered for months of continuous testing
The parts that decide whether a long test finishes: compressor, controls, seals and build.
Tecumseh, Bitzer or GEA BOCK compressors
Protected against motor overheating and over-pressure, and mounted on vibration dampers.
7-inch touch screen
Time-segment and real-time programming, 100 programs × 100 steps.
Remote PC control
Live curves, compressor status and alarms over the network.
No dripping condensation
Air circulation keeps the chamber ceiling dry, so no water drips onto samples in hot, humid tests.
Auto-return to ambient
After a program ends the chamber returns to room temperature to protect samples.
Frost-free sealing
Double silicone seals for more than 1000 hours of frost-free running.
SUS304 inside and out
2 mm fully welded inner chamber, 1.5 mm outer shell, PU foam and rock wool insulation.
Heated viewing window
Double glass with a heater, plus a 100 mm cable port for live testing.
Safety and standards
Protection for the sample, the refrigeration system and the operator.
Show all 10 safety protections
- Sample over-temperature protection
- Motor overload protection
- Compressor overload protection
- Compressor over-pressure protection
- Humidifier dry-burn protection
- Water shortage protection
- Phase loss and reversal protection
- Electrical leakage protection
- Three-color alarm light
- Flame-retardant non-metallic materials
Show the reference standards: IEC 60068, GB/T, GJB150
Find the right LORDERAN environmental chamber
Steady climate, fast ramps or instant shock: choose by how your product must be stressed.
Questions buyers ask
Options, warranty, returns, delivery and quotes.
How low can the humidity go?
20 %RH as standard from 45 °C upward. With the optional low-humidity function, down to 10 %RH from 40 °C; the function is also needed for any humidity test at 10–20 °C. Tell us your test temperature when you order and we tune the system before shipping.
What does the warranty cover?
A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded. A 2-year extended warranty can be added in the configurator.
Can I add shelves or a larger test hole?
Yes. Additional shelves and a custom test hole can be added in the configurator. If a custom hole could affect the door or wall sealing, we contact you before production.
Can I return it?
Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.
How is it delivered, and when does it ship?
Freight, duties and taxes are paid to your loading dock; moving the chamber inside is not included. Your confirmed ship date is included in the order acknowledgement.
Can I get a formal quote for a purchase order?
Yes. Select your size and options, then click Get a quote for a PDF quotation with DDP shipping included.
Choose size, voltage and options
The price, delivery date and PDF quote update with your choices.