Steam Sterilizer

LORDERAN 35L, 50L, 100L, 150L Vertical Sterilizer Autoclave with Traditional Bolt Structure Lid, Automatic Exhaust, Large Laboratory Steam Sterilizer

SKU
35B-2
Availability
In stock
Questions

Ask about this instrument

LORDERAN 35L, 50L, 100L, 150L Vertical Sterilizer Autoclave with Traditional Bolt Structure Lid, Automatic Exhaust, Large Laboratory Steam Sterilizer

An engineer replies by email or phone, usually within 12 hours.

Volume · 35L
Power · 220V

A vertical high-pressure steam sterilizer for culture media, mushroom spawn and lab waste, with a traditional bolt-down lid and an all-SUS 304 stainless steel build. Set the temperature and the time, close the lid, and the cycle runs on its own: it heats, holds, exhausts automatically, then beeps and switches off. Four sizes from 35 to 150 L, with stackable baskets that make loading and unloading easy; the 150L is 220 V only.

LORDERAN121.0°C134 °C max33 psi35–150 L
35–150 Lfour chamber sizes
116–134 °Csterilizing range
33 psi0.23 MPa working pressure
≤ 0.5 °Ctemperature uniformity
4–999 minsterilization timer
Mushroom cultivation and grain spawnMicrobiology labsCulture mediaGlassware and instrumentsTeaching labs

How does a cycle run?

Set temperature and time, close the lid. It heats, holds, exhausts automatically, then beeps and switches off.

110 V or 220 V?

Up to 100L, both are offered. The 150L draws 6 kW, so it is supplied for 220–240 V only.

What is checked before it ships?

Pressure hold at 33 psi, a full cycle at 134 °C, lid seal, safety valve, water protection and both element alarms.

Are spare parts available?

Yes. Heating elements, gaskets, sensors and valves are designed to be easy to replace.

Vertical Steam Sterilizer Autoclave datasheetFull specifications for the 35L, 50L, 100L and 150L models on one printable sheet: chamber, baskets, heating, power and shipping data.Download datasheet
A note from LORDERAN

We know trust has to be earned back.

Some of you told us that an earlier sterilizer did not hold up the way it should have. We heard every one of those messages, and we are not going to pretend otherwise.

A sterilizer is a machine you trust with your cultures, your spawn and your working day. So we went back to the parts that matter most: the heating elements, the lid seal, the sensors and the controls, and to how each unit is checked before it leaves us. We would rather show you than ask for your word. Here is exactly what we check.

LThe LORDERAN teamEngineering, quality and customer support

Inside the vessel

Water sits in the bottom of the chamber over two heating elements. Steam rises through two stacked stainless baskets, a flexible PT-100 probe reads the temperature at the load, and the bolt-down lid seals the vessel to 33 psi.

Pressure gaugeOver-pressure safety valveBolt-down lid with gasketFlexible PT-100 sensorTwo stacked SS304 basketsSaturated steam, up to 134 °CLow-water level sensorTwin heating elementsAuto-exhaustvalveManual drainSUS 304 stainless steel chamber1Pressure gauge2Over-pressure safety valve3Bolt-down lid with gasket4Flexible PT-100 sensor5Two stacked SS304 baskets6Saturated steam, up to 134 °C7Low-water level sensor8Twin heating elements9Auto-exhaust valve10Manual drain11SUS 304 stainless steel chamber
134 °Cmaximum temperature
0.23 MPaworking pressure
≤ 0.5 °Cheat average
≈25 minto pressure

Why it runs under pressure

Water boils at 100 °C at normal air pressure. To reach 121 °C or 134 °C, steam has to be held above atmospheric pressure, which is why the chamber is a pressure vessel. Air has to be removed first: an air and steam mixture at the same pressure is cooler than pure steam. At 134 °C the steam needs about 0.20 MPa, below the 0.23 MPa this unit is rated for.

0.00.10.20.3100110120130140temperature, °Cpressure, MPa gaugeworking pressure 0.23 MPa116 °C · lowest set point0.07 MPa (11 psi)121 °C · standard cycle0.10 MPa (15 psi)134 °C · maximum0.20 MPa (29 psi)pressure above atmospheric0.00.10.20.3100110120130140temperature, °Cpressure, MPa gaugeworking pressure 0.23 MPa116 °C · lowest set point0.07 MPa (11 psi) above atmospheric121 °C · standard cycle0.10 MPa (15 psi) above atmospheric134 °C · maximum0.20 MPa (29 psi) above atmospheric

Saturated steam pressure calculated with the IAPWS-IF97 equations, shown above atmospheric pressure (gauge). Pure steam with all air removed.

Specifications

Models 35B, 50B, 100B and 150B. The 35L, 50L and 100L are offered in 110 V and 220 V versions; the 150L is 220 V only.

Download the full datasheet (PDF)

Differs between models

Model 35 L 50 L 100 L 150 L
Model
SKU 35B 50B 100B 150B
Performance
Working pressure 33psi (0.23mpa)
Max temperature 134 °C
Temp. setting range 116 to 134 °C (240.8 to 273°F)
Heat average ≤ 0.5 °C
Sterilization timer range 4 to 999mins
Chamber and loading
Inner chamber capacity φ300x450 mm φ350x515 mm Φ450x620 mm ф500x747 mm
Baskets quantity 1*(φ275x395 mm) 2*(φ325x235 mm) 2*(φ425x275 mm) 2*(φ475x365 mm)
Operation
Exhaust method Automatic exhaust
Drainage Manual drainage
Temperature Sensor Flexible PT-100 temperature sensor
Electrical
Heating Element 1 kW*1, 1.5 kW*1 1.5 kW*2 1.5 kW*1, 3 kW*1 3 kW*2
Power 2.5 kW, 12amps(220 V), 21amps (120 V) 3 kW, 13.6amps(220 V), 25amps (120 V) 4.5 kW, 20.5amps(220 V), 37.5amps (120 V) 6Kw, 220-240 V, 27 A, 60 Hz, single phase
Dimensions and weight
Overall dimensions 436x473x850 mm 544x536x985 mm 617x627x1135 mm 660x676x1255 mm
Packing Dimensions 550x500x900 mm 580x630x1100 mm 690x650x1230 mm 750x700x1370 mm
G.W / N.W 58/41 kg 75/53 kg 104/78 kg 123/90 kg

Choose a size

Same pressure, temperature range, controls and protection on every model. They differ in chamber size, baskets and heating power. Drawn to the same scale; the dashed outline is the inner chamber.

35L436 × 473 × 850 mmchamber φ300 × 45050L544 × 536 × 985 mmchamber φ350 × 515100L617 × 627 × 1135 mmchamber φ450 × 620150L660 × 676 × 1255 mmchamber φ500 × 747Dashed outline: inner chamber, drawn to the same scale35L436 × 473 × 850 mmchamber φ300 × 45050L544 × 536 × 985 mmchamber φ350 × 515100L617 × 627 × 1135 mmchamber φ450 × 620150L660 × 676 × 1255 mmchamber φ500 × 747
150 L158 quart chamber=30 qt30 qt30 qt30 qt30 qtfive 30-quart stovetop pressure cookersOne cycle, one set point, no stove to watch150 L=30 qt30 qt30 qt30 qt30 qt158-quart chamber ≈ five 30-quart pressure cookers
For mushroom growers

One 150L = five 30-quart cookers

Sterilize grain spawn in one cycle, with no stove to watch.

  • 158 qt150L chamber
  • ≈25 minto pressure
  • Pasteurizeadjustable temperature for substrate

One button, one full cycle

Set the temperature and the time. The controller heats, holds, exhausts, then beeps and switches itself off. Fewer settings mean fewer things to go wrong.

Heat upabout 25 min to pressureSterilize4–999 min, timer you setExhaustauto or non-ventDonebeep, power off20 °C60 °C100 °C116 °C134 °CSet point 116–134 °C, ±0.5 °Ce.g. 121 °C holdNon-vent: pressure falls slowlyAutomatic exhaust116–134 °C12341Heat upabout 25 min to pressure2Sterilize4–999 min, timer you set3Exhaustauto or non-vent4Donebeep, power off

Automatic exhaust

Pressure is released when the timer ends. The quick choice for dry goods, glassware, instruments and grain spawn bags.

Non-vent mode

The vessel stays sealed and pressure falls slowly. Use it for liquids and media to prevent boil-over. One button switches modes.

What we check on every unit

Each sterilizer passes this checklist before it is packed. If one item fails, the unit does not ship.

Pressure holdBrought to 33 psi (0.23 MPa) and held with no leak.
Full cycle at 134 °CHeat, sterilize and exhaust at maximum temperature.
Lid and gasket sealBolt-down lid checked for an even seal all round.
Safety valveOver-pressure release verified.
Water protectionLow-water and dry-run protection triggered and confirmed.
Both element alarmsEach heating element and its alarm tested.

When it arrives, put a standard biological or chemical indicator in your first load and confirm the result for yourself.

134Over-temperatureOver-pressure ventingSafety valveLow-water cut-offAnti-dry burningLeakage breakerDual-element alarmsAuto shut-off, beep1Over-temperature2Over-pressure venting3Safety valve4Low-water cut-off5Anti-dry burning6Leakage breaker7Dual-element alarms8Auto shut-off, beep

Protection at every layer

The unit watches temperature, pressure and water level throughout the cycle. If anything goes outside its limit, it protects itself and tells you. Each of the two heating elements has its own audible and visual alarm, so a fault points straight to the part to replace.

  • Over-temperature protection
  • Over-pressure self-venting
  • Safety valve on the lid
  • Low water level protection
  • Dry-run protection
  • Leakage breaker
  • Alarm for each heating element
  • Auto shut-off with beep

110 V or 220 V?

The same power drawn at half the voltage needs twice the current. Up to 100L, both supplies are offered. At 6 kW, the 150L would need about 50 A at 120 V, so it is supplied for 220–240 V only.

220 V current120 V currentTypical 15–20 A breaker
35L2.5kw
12 A at 220 V
21 A at 120 V
50L3kw
13.6 A at 220 V
25 A at 120 V
100L4.5kw
20.5 A at 220 V
37.5 A at 120 V
150L6Kw
27 A at 220 V
≈50 A at 120 V, not offered
0 A20 A breaker30 A40 A50 A
Why is the 150L 220 V only?
15–20 A

Circuit and breaker limits

Standard residential and light laboratory circuits in North America are typically protected by 15–20 A breakers, and codes such as the NEC derate breakers to 80% for continuous loads.

4–6 AWG

Wiring and material cost

Carrying 50 A safely needs much thicker wire, typically 4 or 6 AWG depending on conditions. That makes a 120 V install impractical and costly.

≈30 A

The lab standard

208 V or 220 V single-phase power at around 30 A is the common laboratory supply, and it runs the 150L comfortably.

Honest answers

The questions we hear most from people who have been let down before.

What if my unit has a problem?

Contact us with your order number and a short description or video. An engineer will work through it with you. Major defects under the 1-year warranty are covered by a full refund or replacement.

Can I get spare parts?

Yes. Heating elements, gaskets, sensors and valves are designed to be easy to replace, and each heating element has its own alarm so you know which part to change.

What if it is not right for me?

Return it within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

Will there be surprise costs on delivery?

No. Shipping is free and delivered duty paid (DDP): freight, duties and taxes are paid to your loading dock. Moving the autoclave inside is not included. Your confirmed ship date is included in the order acknowledgement.

What does the warranty cover?

A 1-year warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded.

Can I get a formal quote for a purchase order?

Yes. Select your size and voltage, then click Get a quote for a PDF quotation with DDP shipping included.

Full feature list: design, operation and safety

Design

  • Small footprint
  • Full SS304 construction
  • Bolt-down lid structure
  • Large load capacity
  • LED display of working status
  • Built-in cooling fan
  • Built-in voltage regulator

Operate

  • Fully automatic cycle
  • Easy setting: temperature and time
  • Up to 134 °C
  • One-button auto-exhaust or non-vent
  • Two stackable baskets included
  • Adjustable temperature for pasteurizing

Safety

  • Safety valve
  • Overpressure protection
  • Anti-dry burning
  • Leakage breaker
  • Water level sensor with automatic shut-off
  • Audible and visual alarms

Download documents

The datasheet covers all four models. The user manual explains installation, operation and maintenance.

Choose size and voltage

The price and PDF quote update with your choices.

Configure yours