Dry Cabinet

LORDERAN Nitrogen Dry Cabinet, N2 Desiccator 1-60% RH Ultra-Low Humidity Storage for Semiconductor, Optics & Lab

SKU
320ED
Availability
In stock
Questions

Ask about this instrument

LORDERAN Nitrogen Dry Cabinet, N2 Desiccator 1-60% RH Ultra-Low Humidity Storage for Semiconductor, Optics & Lab

An engineer replies by email or phone, usually within 12 hours.

Capacity · 320L

A nitrogen-purged dry cabinet for the most moisture- and oxidation-sensitive parts. Dry nitrogen continuously displaces the moist air inside, driving relative humidity down to as low as 1 % and holding it anywhere from 1 to 60 % RH. Once the target is reached the system stops purging by itself. Humidity control only, not temperature.

1–60 % RHNitrogen purgeAuto stop at targetAntistaticJ-STD-033C
25.0°C3%RHN₂1–60 % RHN₂ purgeAntistatic
1–60 %RH, nitrogen purged
±3 % RHHoneywell sensor
320–1436 Lfour sizes
> 80 kgper shelf
2 yearsfull warranty
Photography and opticsElectronicsPharmaceuticalsMuseums and archivesManufacturing
2-year warrantyMajor defects: full refund or replacement.
Free shipping, DDPDuties paid, no surprise import charges.
30-day money backReturn most new, unopened items.
110 V or 220 V50/60 Hz, choose at order.
TECHNICAL DATASHEET · PDF · 5 PAGES

Nitrogen Dry Cabinet, 320–1436 L datasheet

Full specifications, dew point reference values, storage notes for moisture-sensitive parts, installation and warranty in one document to share with your team.
Download datasheet

Nitrogen in, moisture out

Dry nitrogen is fed into the sealed cabinet and pushes the moist air out. When the Honeywell hygrometer sees your target, purging stops and the flow is regulated for even distribution. Open the door and it starts again, bringing humidity back down fast.

% RHtime →Your targetN₂ flowingTarget reached, purge stopsDoor openedPurge resumes,then stops again
1 %RH, lowest level
Autostop at target
Inertguards against oxidation
±1 °Ctemperature display

Specifications

Sizes 320L, 540L, 870L and 1436L. Humidity control only, not temperature. 110V or 220V, 50/60Hz.

Differs between models

Model 320L 540L 870L 1436L
Capacity and size
Capacity 11.3 cu ft 19.06 cu ft 30.72 cu ft 50.71 cu ft
External Size (W*D*H) 900*450*1010mm 598*710*1465mm 900*600*1890mm 1200*710*1910mm
Internal Size (W*D*H) 898*422*848mm 596*682*1298mm 898*572*1698mm 1198*682*1723mm
Shelves 3, adjustable 3, adjustable 5, adjustable 5, adjustable
Control
Humidity Range 1%–60% RH
Drying Method Nitrogen displacement
Display Precision ±3% RH, ±1°C
AC Power 110V or 220V, 50/60Hz
Antistatic Yes

Humidity down to 1 % RH

Everyday room air is far wetter than sensitive parts can tolerate. Set any target from 1 to 60 % RH.

1%2%5%10%20%50%100%Relative humidity, log scale← drierwetter →Everyday room air1–60 % RH, nitrogen purgedSet any target in the range; nitrogen displaces the moist air
1%5%10%20%50%100%Relative humidity, log scale← drierwetter →Everyday room air1–60 % RH, nitrogen purgedSet any target from 1 to 60 % RH

Four sizes, one standard

Front elevations drawn to the same scale. Every size has adjustable shelves rated for more than 80 kg each.

320L900 mm3 shelves · 11.3 cu ft540L598 mm3 shelves · 19.06 cu ft870L900 mm5 shelves · 30.72 cu ft1436L1200 mm5 shelves · 50.71 cu ft

Built to protect what you store

Conforms to IPC/JEDEC J-STD-033C, CE and RoHS certified.

Airtight construction

A well-sealed enclosure keeps outside air and moisture from getting in.

Intelligent nitrogen filling

Purging stops automatically at the target and gas flow is regulated for even distribution.

Honeywell humidity sensor

Error as small as ±3 % RH, so the set humidity is held where you need it.

Dual LED display

Temperature and humidity side by side, with no need to switch readings.

Abnormal-humidity alarm

Flash and buzzer the moment humidity goes out of range.

Locking doors

Zinc alloy press lock and robust cylinder locks against unauthorised access.

Antistatic finish

RoHS powder coating with DuPont powder protects stored goods from pollution and static shock.

13-step coating

Electrostatic powder coating on body and partitions, built to last over 15 years.

Shelves for heavy loads

Every adjustable shelf supports more than 80 kg.

Electronic or nitrogen?

Two ways to keep things dry, in the same four sizes.

Cabinet
How it dries
Electronic dehumidification unit
Dry nitrogen displaces moist air
Humidity
Choose 20–60, 10–20, 1–10 or 1–5 % RH
1–60 % RH
Extra benefit
No gas supply needed
Inert atmosphere also guards against oxidation
Sizes
320, 540, 870, 1436 L
320, 540, 870, 1436 L

Questions buyers ask

Straight answers before you order.

Do I need a nitrogen supply?

Yes. The cabinet is connected to a dry nitrogen source; the built-in flowmeter regulates the flow and purging stops automatically once the target is reached.

How low can humidity go?

Down to 1 % RH. You can set any level from 1 to 60 % RH.

Nitrogen or electronic?

Choose nitrogen when you need the lowest humidity fast, or an inert atmosphere against oxidation. The electronic cabinet needs no gas supply.

Does it control temperature?

No. It controls humidity only; temperature is displayed to ±1 °C.

Which voltage?

110 V or 220 V, 50/60 Hz.

Free shipping

Free shipping on all orders, with some international restrictions.

2-year warranty

Two-year full warranty. Major defects under warranty are covered by a full refund or replacement.

30-day money back

Return most new, unopened items within 30 days.

DDP shipping

Delivered duty paid, so there are no surprise import charges on arrival.